Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Incinerator

Listing ID #1532844

  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world

JATINDERA BOILER COMPANY is a reliable name, which can be trusted for the manufacturing and exporting of Waste Incinerators. These Waste Incinerators are precisely engineered by experts, which are....
View More Details
Send Enquiry

Company Information

  • Member Since 15 Years
  • Nature of Business Retailer
  • Year of Establishment 2003

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

JATINDERA BOILER COMPANY is a reliable name, which can be trusted for the manufacturing and exporting of Waste Incinerators. These Waste Incinerators are precisely engineered by experts, which are hugely demanded by clients. It can be used in Hotels, Embassies, Govt. Offices, Banks, Hostels, and in research of animals.


Construction :

  • Package type and Incineration is batch type
  • All weather type and mounted on base frame for easy transportation
  • Waste feeding is manual
  • Incinerator has 2 chambers
    • Primary chamber
    • Secondary chamber
  • Both chambers are provided with pressure jet burners for incineration of bio-medical waste
  • For general waste burner is provided only in primary chamber
  • The primary chamber is provided with air pressure nozzles
  • Cyclone separator is provided and mounted on the base frame of the incinerator
  • Ensure that no ash particles are let out of the exhaust
  • Quality of incineration achieved is excellent
  • A dust proof pre-wired control panel housing all safeties, temperature controllers for primary chamber, secondary chamber, and flue gas temperatures are provided
  • Incorporates contactors, overload relays and MCBs for electrical
  • Alarm hooter is provided along with audio & visual alarms for abnormal working conditions
  • In case of defect in the process, the incinerator comes to a standstill and the fault is indicated on the control panel
  • Suitable protection for burner is provided. Forced draft fan is mounted on the base frame of the incinerator to provide combustion air for incineration of waste
  • Waste charging door and ash removal door is provided on the incinerator
  • The incinerator is refractory lined and does not require any civil works at site. Even the forced draft fan and the incineration chambers need no civil works as these are mounted on a base frame.


Applications :

  • For General Waste Like :
    • Paper
    • Timber
    • Refusing textures
    • Leather
    • Rice grass
    • Non-eatable foods
    • Synthetic resin
    • Rubber
    • Tyres
    • Oil socked Cotton / Cloth Waste

 

  • For Medical Waste Like :
    • Discarded medicines
    • Cytologic drugs (waste comprising of out dated, contaminated and discarded medicines)

 

  • For Animal Waste :
    • Animal tissues
    • Organs
    • Body parts
    • Carcasses
    • Bleeding parts
    • Fluid
    • Blood

 

  • For Solid waste :
    • Items contaminated with blood, and body fluids including cotton, dressings, solid plasters casts, lines, bleeding, and other material contaminated with blood


For Medical Waste Incinerators :

Model Capacity Incinerator Inlet gate Burning Scale Burning Scale Temperature (°C ) Floor Area - Kg/hr Net Height (mm) Cross Height (mm) WxL
(mm) m3 m2 1st incinerator 2nd incinerator WxL
(mm) MW 40 40-50 1500 2600 750x850 1.79 2.30 800±50 1000±50 1350x3090 MW 60 60-80 1630 2800 900x1000 2.54 3.81 800±50 1000+50 1510x3570 MW 90 90-100 1770 3400 950x1000 3.98 5.11 800+50 1000+50 1990x4390 MW 150 150-160 2000 3750 1100x1000 4.76 7.37 800±50 1000±50 2050x4700


Note :

  • We reserve the right to change any specification without prior notice.


For General Waste Incinerators :

Model Capacity Kg/hr Incinerator Area over Fire m3 Burning Capacity m2 Cyclone
(wxh)
mm Stack Floor Area m2 1st Chamber (HxWxL) mm 2nd Chamber (wxh) mm Height on ground (mm) (mm) GW 30 30-40 1010x1905x1430 920x930 0.56 1.26 820x2230 5580 320 4.7 GW 60 50-60 1080x2165x1525 1000x940 0.95 1.62 920x2300 5650 360 5.18 GW 90 80-100 1330x2130x1640 1000x1000 1.08 2.31 1016x2540 5890 390 5.99

 

  • We reserve the right to change any specification without prior notice.


Product Images

  • incinerator
  • incinerator
  • incinerator
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for incinerator?

Quantity
Seller Contact Details
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Incinerator at Best Price in Delhi - ID: 1532844 | JATINDERA BOILER COMPANY
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Incinerator

Listing ID #1532844

  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world

JATINDERA BOILER COMPANY is a reliable name, which can be trusted for the manufacturing and exporting of Waste Incinerators. These Waste Incinerators are precisely engineered by experts, which are....
View More Details
Send Enquiry

Company Information

  • Member Since 15 Years
  • Nature of Business Retailer
  • Year of Establishment 2003

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

JATINDERA BOILER COMPANY is a reliable name, which can be trusted for the manufacturing and exporting of Waste Incinerators. These Waste Incinerators are precisely engineered by experts, which are hugely demanded by clients. It can be used in Hotels, Embassies, Govt. Offices, Banks, Hostels, and in research of animals.


Construction :

  • Package type and Incineration is batch type
  • All weather type and mounted on base frame for easy transportation
  • Waste feeding is manual
  • Incinerator has 2 chambers
    • Primary chamber
    • Secondary chamber
  • Both chambers are provided with pressure jet burners for incineration of bio-medical waste
  • For general waste burner is provided only in primary chamber
  • The primary chamber is provided with air pressure nozzles
  • Cyclone separator is provided and mounted on the base frame of the incinerator
  • Ensure that no ash particles are let out of the exhaust
  • Quality of incineration achieved is excellent
  • A dust proof pre-wired control panel housing all safeties, temperature controllers for primary chamber, secondary chamber, and flue gas temperatures are provided
  • Incorporates contactors, overload relays and MCBs for electrical
  • Alarm hooter is provided along with audio & visual alarms for abnormal working conditions
  • In case of defect in the process, the incinerator comes to a standstill and the fault is indicated on the control panel
  • Suitable protection for burner is provided. Forced draft fan is mounted on the base frame of the incinerator to provide combustion air for incineration of waste
  • Waste charging door and ash removal door is provided on the incinerator
  • The incinerator is refractory lined and does not require any civil works at site. Even the forced draft fan and the incineration chambers need no civil works as these are mounted on a base frame.


Applications :

  • For General Waste Like :
    • Paper
    • Timber
    • Refusing textures
    • Leather
    • Rice grass
    • Non-eatable foods
    • Synthetic resin
    • Rubber
    • Tyres
    • Oil socked Cotton / Cloth Waste

 

  • For Medical Waste Like :
    • Discarded medicines
    • Cytologic drugs (waste comprising of out dated, contaminated and discarded medicines)

 

  • For Animal Waste :
    • Animal tissues
    • Organs
    • Body parts
    • Carcasses
    • Bleeding parts
    • Fluid
    • Blood

 

  • For Solid waste :
    • Items contaminated with blood, and body fluids including cotton, dressings, solid plasters casts, lines, bleeding, and other material contaminated with blood


For Medical Waste Incinerators :

Model Capacity Incinerator Inlet gate Burning Scale Burning Scale Temperature (°C ) Floor Area - Kg/hr Net Height (mm) Cross Height (mm) WxL
(mm) m3 m2 1st incinerator 2nd incinerator WxL
(mm) MW 40 40-50 1500 2600 750x850 1.79 2.30 800±50 1000±50 1350x3090 MW 60 60-80 1630 2800 900x1000 2.54 3.81 800±50 1000+50 1510x3570 MW 90 90-100 1770 3400 950x1000 3.98 5.11 800+50 1000+50 1990x4390 MW 150 150-160 2000 3750 1100x1000 4.76 7.37 800±50 1000±50 2050x4700


Note :

  • We reserve the right to change any specification without prior notice.


For General Waste Incinerators :

Model Capacity Kg/hr Incinerator Area over Fire m3 Burning Capacity m2 Cyclone
(wxh)
mm Stack Floor Area m2 1st Chamber (HxWxL) mm 2nd Chamber (wxh) mm Height on ground (mm) (mm) GW 30 30-40 1010x1905x1430 920x930 0.56 1.26 820x2230 5580 320 4.7 GW 60 50-60 1080x2165x1525 1000x940 0.95 1.62 920x2300 5650 360 5.18 GW 90 80-100 1330x2130x1640 1000x1000 1.08 2.31 1016x2540 5890 390 5.99

 

  • We reserve the right to change any specification without prior notice.


Product Images

  • incinerator
  • incinerator
  • incinerator
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for incinerator?

Quantity
Seller Contact Details
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice