Listing ID #1360007
Company Information
Ask for more detail from the seller
Contact SupplierThe Stationed Hydrogen Leak Detector Input Device (CHS-HTR - PH-100-(2W)), we bring forth, is acknowledged for its high efficiency and unmatched performance to detect the leak of hydrogen. That’s why it is extensively demanded by several industries including nuclear, coal, gas, fuel cells, etc. We are one of the leading Manufacturers and Suppliers of Hydrogen Leak Detector (CHS-HTR - PH-100-(2W)) in Nagpur, Maharashtra.
Details :
CHS-HTR-PH-100-5V-CM, is an input device compatible for HY-102D (R3),- S4H Make, Digital Transmitter, H2-485 Tx-8 CH –Acorn Control Make, or User interface. The Transducer houses a solid state electrochemical Sensor which directly, specifically and intelligently measures hydrogen gas presence in surrounding gaseous fluid medium, with a self generated output, carried through two-wires for FS. The sensor is housed in Teflon and the Transducer housing is metallic chosen from among, Brass (Plated) and MS(Plated) or SS to suit the environment.
Unlike most sensors, the measuring capability is direct and is not based on co-relation methods. Operating at Room Temperatures, in-built heaters are not required and most importantly, it does not suffer any consequence up on exposure to high hydrogen, a very crucial feature in safety applications.
It is flexible for mounting, through female threaded adapter, on Walls/ceiling or submerged in any machine/pipe line. Separate Calibration system is available and the transducer design is compatible for in-situ attempts, in a user friendly way.
Transducer | 2 Wires in metal housing containing sensor. Intrinsically safe. Exia II-C |
---|---|
Specificivity | Specific & selective only to Hydrogen |
Sensor Technology | Solid State Electrochemical Cell (Direct Partial Pressure Measurement of Hydrogen in gaseous Fluid). (Proprietary, Indian Patent No. 252998 w.e.f 14/06/2007). |
Dimensions | 32 mm Φ x 54 mm ( 1 & 1/8” BSB x 12mm deep, Threaded Head ) |
Power To Sensor | Nil (Self Generated Signal) |
Sensor Output | Two wire from sensor (current signal) terminated with interface compatible connector. |
Sampling | By Diffusion |
Housing Material | Brass & MS plated for non- corrosive, SS316 for corrosive environment, respectively. |
Response Time | < 3 seconds |
Accuracy | ±10 % FSD |
Gas Sample Aperture | Φ 2 mm |
Compatible Interface | CURRENT TRANSMITTER – S4H-Tx-01 |
Mounting | Flexible for mounting, through female threaded adapter, on Walls/ceiling or submerged in any machine/pipe line. |
Connectivity | 2-core Teflon-Teflon shielded (SPC) 7/34 cable and Interface compatible connector at both ends. Part No. 2C(SPC)-T/T-34 SWG |
Adaptor | Non-metallic Threaded 1 & 1/8th” (F) with Metal suspender. |