Nominal Cross Section Area of Conductor mm2 | Number/Nom. Dia. of wires (nom.) No./mm | Thickness of Insulation (Nom.) mm | Overall Diameter Max. (mm) | Current carrying capacity Amps | Resistance (Max.) per Km. at 20 ' C Ohms |
1 | 14/0.3 | 0.7 | 3.2 | 11 | 18.1 |
1.5 | 22/0.3 | 0.7 | 3.4 | 13 | 12.1 |
2.5 | 36/0.3 | 0.8 | 4.2 | 18 | 7.41 |
4 | 56/0.3 | 0.8 | 4.8 | 24 | 4.95 |
6 | 84/0.3 | 0.8 | 5.6 | 31 | 3.3 |
Single Core Flexibles
Nominal Cross Section Area of Conductor mm2 | Number/Nom. Dia. of wires (nom.) No./mm | Thickness of Insulation (Nom.) mm | Overall Diameter Max. (mm) | Current carrying capacity Amps | Resistance (Max.) per Km. at 20 ' C Ohms |
10 | 141/0.3 | 1 | 8 | 51 | 1.91 |
16 | 126/0.4 | 1 | 9.6 | 68 | 1.21 |
25 | 196/0.4 | 1.2 | 11.5 | 86 | 0.78 |
35 | 276/0.4 | 1.2 | 13 | 110 | 0.55 |
50 | 396/0.4 | 1.4 | 15 | 145 | 0.39 |
Multi Core Flexibles
Nominal Cross Section Area of Conductor mm2 | Number/Nom. Dia. of wires No./mm | Thickness of Insulation (Nom.) mm | Thickness of Sheath (Nom.) 2core, 3core, 4core | Overall Diameter Max. (mm) | Current carrying capacity | Resistance (Max.) per Km. at 20 ' C Ohms | ||||
mm | mm | mm | 2core | 3core | 4core | |||||
0.5 | 16/02 | 0.6 | 0.9 | 0.9 | 0.9 | 7.2 | 7.6 | 8.2 | 4 | 39 |
0.75 | 24/0.2 | 0.6 | 0.9 | 0.9 | 0.9 | 7.8 | 8.2 | 8.8 | 7 | 26 |
1 | 32/0.2 | 0.6 | 0.9 | 0.9 | 0.9 | 8 | 8.6 | 9.4 | 11 | 19.5 |
1.5 | 48/0.2 | 0.6 | 0.9 | 0.9 | 1 | 8.6 | 9.2 | 10.5 | 15 | 13.3 |
2.5 | 80/0.2 | 0.7 | 1 | 1 | 1 | 10.5 | 11 | 12 | 20 | 7.98 |
4 | 56/0.3 | 0.8 | 1 | 1 | 1 | 12 | 12.5 | 14 | 26 | 4.95 |
![]() | Sheath : Tough outer sheath of PVC compound abrasion resistant, impervious to water, oil & grease thereby giving long life and electrical safety. |
Motor HP Vs Current
H.P | 5 | 7.5 | 10 | 12.5 | 15 | 17.5 | 20 | 25 | 30 | 35 | Amp | 7.5 | 11 | 14.9 | 18.9 | 22.5 | 25.2 | 28.4 | 35.6 | 42.3 | 50.4 |
Dearting Factors in Ground
Ambient Temperature (Deg. C) | 30 | 35 | 40 | 45 | 50 | Derating Factor | 1.09 | 1.04 | 1 | 0.95 | 0.77 |
Three-core Flat Submersible Cables in Voiltage Grade upto & Including 1100 V (IS : 694 : 1990)
Area (Nom.) Sq. mm | Number/size of Wire | Insulation Thickness (Nom.) mm | Sheath Thickness (Nom.) mm | Width 'W' (Approx) mm | Thickness 'T' (Approx) mm | Resistance at 20°C (Max.) ohm/Km | Current carrying capacity at 40°C Amps |
1.5 | 22/0.3 | 0.6 | 0.9 | 11 | 5 | 12.1 | 14 |
2.5 | 36/0.3 | 0.7 | 1 | 13 | 6 | 7.4 | 18 |
4 | 56/0.3 | 0.8 | 1 | 15.3 | 6.7 | 4.95 | 26 |
6 | 84.0.3 | 1 | 1.15 | 18.7 | 7.9 | 3.3 | 31 |
10 | 140/0.3 | 1 | 1.4 | 23.7 | 9.9 | 1.91 | 42 |
16 | 226/0.3 | 1 | 1.4 | 28 | 11.4 | 1.21 | 57 |
25 | 354/0.3 | 1.2 | 2 | 35.5 | 14.7 | 0.78 | 72 |
35 | 495/0.3 | 1.2 | 2 | 39.5 | 16.2 | 0.55 | 90 |
50 | 703/0.3 | 1.4 | 2.2 | 45.5 | 18.3 | 0.39 | 115 |
70 | 360/0.5 | 1.4 | 2.2 | 51 | 20 | 0.27 | 143 |