Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    Hot Set Test Apparatus (SS Scale Model)

    • Packing : One Wooden Box
    • Chamber Construction:  Double Walled, Inner Chamber made of Stainless Steel, Outer Chamber MS / GI
    • Samples:  2 Samples can be tested at one time
    • Model: SSI 521 HSSS (Hot Set Test Apparatus with Stainless Steel Scales)
    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 16 Years
    • building Nature of Business Retailer
    • Year of Establishment 1985

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • Weight:  2 Sets of Hanger and Weights are provided
    • Delivery : 3 to 4 weeks
    • Temperature Range:  Ambient to 250oC. Test Temperature 200oC, LC 0.1oC
    • Chamber:  300 x 200 x 500 (LBH in mm)
    • Chamber Construction:  Double Walled, Inner Chamber made of Stainless Steel, Outer Chamber MS / GI
    • Temperature Control: Using PID Digital Temperature Controller, +/- 2
    • Elongation Measurement:  2 Dial Gauges are provided to measure the sample Elongation
    •   
    • Packing : One Wooden Box
    • Samples:  2 Samples can be tested at one time
    • Model: SSI 521 HSSS (Hot Set Test Apparatus with Stainless Steel Scales)

    Model Number: SSI 521 HSSS

    Standard Number: IS; 7098 (Pt.1, 2 & 3)IS: 10810 (Pt. 30)

     

    Laboratory Hot Set Test Apparatus is designed to determine the elongation & permanent set of insulation of armored and unarmored single, twin, three , four and multi-core cross linked Polyethylene (XLPE) insulated & PVC sheathed cables for electric supply and control purposes under specified conditions of load temperature and air flow.

     

    Instrument Principle

    Laboratory Hot Set Test Apparatus is designed to determine the elongation & permanent set of insulation of armored and unarmored single, twin, three , four and multi-core cross linked Polyethylene (XLPE) insulated & PVC sheathed cables for electric supply and control purposes under specified conditions of load temperature and air flow, as specified in IS: 7098.

    Standard

    The instrument conforms IS 7098 (Pt.1, 2 & 3), IS: 10810 (Pt.30)

    Instrument

         A double walled cabinet with inside chamber of stainless steel

        Inner dimensions of the chamber are 30 cm x 50 cm  20 cm (W x H x D).

        Full view glass Door to observe the specimen under test.

         Temp. Range 250 ± 2oC. at sensor point. 

        The oven is designed to give 8 to 20 air changes per hour.  

        An air flow meter (Rota meter) is fitted to control and monitor the airflow rate. Range 0- 10 LPM, LC-0.5 LPM

        Grips are provided at the top of the oven to hang specimen/s.

        Suitable weights up to 1 kg are provided with provision to attach the weights to one end of the test pieces.

        Two Stainless Steel Scales are provided for elongation measurement

        A blade is provided in the oven to cut the sample to remove the tensile force without opening the door.

    The sample is hanged using the grips inside the Hot Set Oven along with the weights for 15 mins. The sample starts to elongate due to heat. The elongation of the sample is measured using Dial Gauges. The sample is then cut to evaluate the permanent set. 

    Difference between Hot Air Oven and Hot Set Oven

    The test requirement is 8 to 20 air changes per hour, measured on a Flow Meter. According to IS standard, if the Oven does not have a regulated air supply, the oven is then termed as a Hot Air Oven and not a Hot Air Oven (as offered by some manufactures) and cannot be used for this kind of test

    Also if normal oven is used for the test, the operator will have to open the front door to hang the samples, resulting in loss of temperature. As the test is only 15 mins, it will not be possible to regain the temperature. In our Hot Set oven, we use an especially designed Top Hanger which can be hanged from the top of the Hot Set Oven, without opening the front door. To achieve minimum loss of temperature, we provide two hanger assemblies. One is used as dummy that is used for achieving the desired temperature. In the meanwhile operator can assemble the sample, weights etc on the other hanger, which can be then put in the oven, just be replacing the dummy into the oven. This way the loss in temperature is not more than few degrees.

     

    • Air source to provide 8-20 air changes per hour, a compressor compressed air line of 4 to 10 liters min. is required. If this facility is not already available, a suitable air compressor may be purchased from us.
    • Sample Conditioning: The test specimens are required to be kept at a temperature of 27 ± 2 deg C for a period of 16 hours, immediately before the test. If the conditioning chamber is not available with you, the same can be purchased from us.


    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for Hot Set Test Apparatus (SS Scale Model)?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice