    HIO Keypad Based HMI PLC Flexi Panels

    • Power+ 24V DC ± 10%
    • Radiated emissionas per EN61000-6-4
    • CommunicationTwo communication ports. (User configurable)
    • Surgeas per IEC61000-4-5
    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 16 Years
    • building Nature of Business Retailer

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • Analog Inputs: Voltage Current RTD 0-100 mV, 0-50 mV 0-20 mA, 4-20 mA 3-wire RTD (Alpha1, Alpha2)
    • Immunity to Radiated electromagnetic fieldas per IEC61000-4-3
    • CommunicationTwo communication ports. (User configurable)
    • Storage Temp.-20o to 80o C
    • Immunity to Conducted disturbancesas per IEC61000-4-6
    • Operating Temp.0o to 50o C
    • BezelIP 65 rated keypad
    • Radiated emissionas per EN61000-6-4
    • Immunity to Fast Transientsas per IEC61000-4-4
    • Humidity10% to 90% (Non-condensing)
    • Immunity to ESDas per IEC61000-4-2
    • Surgeas per IEC61000-4-5
    • Power+ 24V DC ± 10%

    Features
    All features of Prizm LCD Operator Interfaces
    Integrated Digital Inputs and Outputs with optional Analog I/O
    Digital Inputs and Outputs rated for 24 V DC
    Analog Inputs for RTD, mV and mA. Analog Output is 4-20 mA
    Inputs connectable to PLC or used for internal program
    Support for Ladder logic and Analog control
    High Speed Counters and Timers 
    Dual Port Support for connecting to a PLC / Printer / SCADA / Drive
    Common Programming software for the entire HIO family.........FREE!!
    IP65 design. CE and UL certified

     

    Basic HIO OperationsThe HIO unit has Prizm (Operator interface) as well as programmable logic features. The user can implement logic, specific to application using standard Ladder programming. The HIO unit has four 32-bit High Speed Counters(Normal and Quadrature Mode), Rate measurement capability (max. up to 25kHz), Timers and Counters, Internal Coils, retentive and non-retentive memory and PID functionality. A PLC logic task can be programmed for continuous scanning, or only when a specific screen is showing. The user can also include a Programmable logic task in power on as well as Global task. The HIO operator interface functions revolve around Screens and Tasks that can be assigned to keys, screens and application. The HIO can also display an Alarm conditions.
    Supported Tasks are listed below:
     

    • Go to Screen 
    • Go to Next Screen 
    • Go to Previous Screen 
    • Write value to Tag 
    • Add a constant value to Tag 
    • Subtract a constant value form Tag 
    • Add Tag B to Tag A 
    • Subtract Tag B to Tag A 
    • Turn Bit On 
    • Turn Bit Off 
    • Toggle Bit  
    • Copy Tag B to Tag A 
    • Swap Tag A and Tag B 
    • Print Data
    • Set RTC
    • Copy Tag to STR
    • Copy Tag to LED
    • Delay
    • Wait
    • Copy Prizm block to Prizm / PLC block
    • Copy Prizm/PLC block to Prizm block
    • Copy RTC to PLC block
    • Execute PLC Logic block 


    Digital I/O
    The HIO Keypad series can have up to 16 digital inputs and 12 digital outputs on the unit. Digital inputs are high impedance 24 V DC and outputs are either relay (NO), open collector or a combination of both. The Digital I/O capability of HIO units can be expanded using external add on I/O Modules.
    Analog I/O
    The HIO controllers can have up to 4 analog inputs and 2 analog outputs. Analog inputs are mA, mV and RTD. Analog outputs are 4-20 mA. The Analog I/O capability of HIO units can be expanded using external add on I/O Modules.
    PID 
    The built-in PID controller can process 12 independent inputs in addition to the Analog inputs of the unit. The input to the PID Controller is a data register, which can hold an analog input or any other value.

    Keys Task
    Keys in HIO can be assigned Tasks for three instances: when the key is pressed , while the key is pressed and when the key is released. Multiple tasks can be assigned to a key. Also different screens can have different key definitions. In addition to above-mentioned tasks, Key’s specific tasks can be defined for keys. These include tasks for data entry, alarm management etc. These definitions allow complete flexibility in cursor control and key operations when changing data.
    Screens
    Up to 65535 screens can be defined in HIO. Screen Tasks can be assigned before showing a screen, while showing a screen and after hiding a screen. Various types of objects such as plain text objects, Data display (coil status, register value, register dependent text), Data entry objects and Alarm objects can be defined on screen. Two screens can be associated to avoid duplication of screens and objects.
    Data entry objects can have limits and math associated. Various types of data formats are available which help the user to edit data easily. Floating Point data entry is supported.
    Alarms
    Alarms can be defined in HIO. Alarms can either be consecutive or discrete. User-friendly alarm object can be defined on the display. Alarms can be real time or historical. Keys can be assigned to acknowledge alarm, view and scroll.
    Dual Port Support
    HIO units (except HIO010) have two communication ports. Both ports can be configured as RS232, CMOS, RS485 / RS422 programming port or to connect a Printer / PLC / SCADA / Drive etc. Drivers can be downloaded in HIO units for Dual Port application
    Configuration Software
    Prizm Setup Software is a compact, Windows® based software to configure the HIO Series Interfaces. Prizm configuration tools and easy approach can help you create your applications quickly and easily. By using Prizm Setup Software features, you can be more effective in presenting your application. Whether you need a small application to monitor data or a bigger application for both monitoring and control, Prizm Setup Software has it all.
    To get started with HIO you need:
    1. HIO unit 
    2. Prizm Setup Software
    3. IBM Cable (Part codes: IBM 0909-1-00 or IBM 0925-1-00)System requirements for Prizm Setup Software are:     Windows Version :       Microsoft Windows® 2000 or above
    Processor :                 266 MHz PENTIUM II or higher
    Mouse :                      Required
    RAM :                         64 MB or more
    Display resolution :      800 x 600 (VGA) or better
    Display colors :           256 colors minimum
    Serial Port :                1 serial port for HIO programming      
    Keyboard :                 Required



    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for HIO Keypad Based HMI PLC Flexi Panels?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice