Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Gas Transmitter with Integrated Area Monitor

Listing ID #4356159

  • Features : 
  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world

The Sensor Transmitter Integrated Area Monitor (ST-IAM) utilises a range of sensor technologies to detect most gases. The ST-IAM can be used on a stand-alone basis or integrated into Controls or....
View More Details
Send Enquiry

Company Information

  • Member Since 8 Years
  • Nature of Business Retailer

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

The Sensor Transmitter Integrated Area Monitor (ST-IAM) utilises a range of sensor technologies to detect most gases. The ST-IAM can be used on a stand-alone basis or integrated into Controls or Building Management Systems (BMS).

 

Application :
  Refrigerant gases all refrigerant gases including: Ammonia, Carbon Dioxide, Hydrocarbons, Halocarbons - HFCs, HCFCs, CFCs.
  Combustible gases such as: Methane, LPG, Propane, Butane, and Hydrogen
  Toxic gases such as: Carbon Dioxide and Ammonia in refrigeration, Hydrogen Sulphide in sewage treatment and Carbon Monoxide in underground car parks
  Volatile Organic Compounds such as: Acetone, Benzene, Carbon Tetrachloride, Chloroform, Ethanol, Toluene, Trichloroethylene.


Features :
 
Technical Specification   ST-IAM Standard          
 
Power Supply  

12/24 V a.c, 12/30 V d.c., 400mA maximum

 
Power Monitoring   Green LED
 
Visual Alarm  

Orange LED for low level
Red LED for high level

 
Analogue Outputs   0-5V, 0-10V, 4-20mA
 
Serial Data Interface   RS 485
 
Digital Outputs   2 Relays rated 1 Amp/24 V d.c /120 V
 
Fault state   0-1V, 0-2mA
 
Analogue Outputs   2 Relays rated 1 Amp/24 V d.c /120 V
a.c Selectable: NO/NC auto or manual reset, response delay 0, 1, 5 or 10 min
 
Dimensions and Weight   1 Relay rated 1 Amp/24 V d.c /120 V a.c
Selectable delay: 0,1,5,10min
 
Dimensions and Weight   155 x 185 x 80 mm 850 g
 
Standard Compliance     WEEE RoHS EuP
 
Sensor Information   ElectrochemicalEC   Semiconductor withfilter (multigas) SC   Catalytic (multigas) CAT   InfraredIR
 
TypicalMeasurement   0-1000ppm   10-1000ppm   ppm- LEL%   ppm - %
 

Range
Temperature Range

 

A: -20°C to +40°C
B: -40°C to +40°C

  -40°C to +50°C   -40°C to +50°C    
 

Humidity Range
non condensing

  0 to 95%   0 to 95%   0 to 95%   0 to 95%
 
Typical Sensor Life   3 yrs   5-8 yrs   5 yrs   5 yrs
 
Alarm threshold T50   19 sec   76 sec(filtered)   28 sec   42 sec
 
                        T90   47 sec   215 sec(filtered)   46 sec   95 sec
 
Recovery Time   900 sec   600 sec   600 sec   8 mins
 
Linearity   Linear over calibrated range
 
Calibration   Local regulations may specify the procedure and frequency required. Standards
 
Requirements   generally require at least annual testing or calibration. Refer to Murco for instructions.
Semiconductor sensors are non-selective, but calibrated to a specific gas.







Features :
 
Technical Specification   ST-IAM Standard          
 
Power Supply  

12/24 V a.c, 12/30 V d.c., 400mA maximum

 
Power Monitoring   Green LED
 
Visual Alarm  

Orange LED for low level
Red LED for high level

 
Analogue Outputs   0-5V, 0-10V, 4-20mA
 
Serial Data Interface   RS 485
 
Digital Outputs   2 Relays rated 1 Amp/24 V d.c /120 V
 
Fault state   0-1V, 0-2mA
 
Analogue Outputs   2 Relays rated 1 Amp/24 V d.c /120 V
a.c Selectable: NO/NC auto or manual reset, response delay 0, 1, 5 or 10 min
 
Dimensions and Weight   1 Relay rated 1 Amp/24 V d.c /120 V a.c
Selectable delay: 0,1,5,10min
 
Dimensions and Weight   155 x 185 x 80 mm 850 g
 
Standard Compliance     WEEE RoHS EuP
 
Sensor Information   ElectrochemicalEC   Semiconductor withfilter (multigas) SC   Catalytic (multigas) CAT   InfraredIR
 
TypicalMeasurement   0-1000ppm   10-1000ppm   ppm- LEL%   ppm - %
 

Range
Temperature Range

 

A: -20°C to +40°C
B: -40°C to +40°C

  -40°C to +50°C   -40°C to +50°C    
 

Humidity Range
non condensing

  0 to 95%   0 to 95%   0 to 95%   0 to 95%
 
Typical Sensor Life   3 yrs   5-8 yrs   5 yrs   5 yrs
 
Alarm threshold T50   19 sec   76 sec(filtered)   28 sec   42 sec
 
                        T90   47 sec   215 sec(filtered)   46 sec   95 sec
 
Recovery Time   900 sec   600 sec   600 sec   8 mins
 
Linearity   Linear over calibrated range
 
Calibration   Local regulations may specify the procedure and frequency required. Standards
 
Requirements   generally require at least annual testing or calibration. Refer to Murco for instructions.
Semiconductor sensors are non-selective, but calibrated to a specific gas.







Company Details close-icon

KAHAN CONTROLS, a young and dynamic company founded in 2003. Since then there has been no looking back. Company started business by representing Dixell Italy as a Sole Distributor for India market. Now company is representing more than 8 MNCs exclusively in India market. Company is one of the leader in providing Controls, Automation & Technological products to Refrigeration industry with supplies to all major OEMs, Contractors & End Customers. To strive future growth, company is also focusing for HVAC Building Automation market from past few years and aiming to have sizeable market share of IBMS.
Now, KAHAN CONTROLS operates with head office in Mumbai, South regional office in Chennai and North regional office in Delhi. KAHAN CONTROLS operates in two major verticals i.e. OEM supplies and complete integrated project solutions. Company has shown tremendous growth in a short span of 9 years since incorporation.
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer / Retailer
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Gas Transmitter with Integrated Area Monitor?

Quantity
Seller Contact Details

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice