Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Flame Photometer

Listing ID #4284114

  • Suction Jet of Samples<6ml/min
  • Response Time<8 sec
  • Weight18 Kg
  • Dimension380 x 770 x 570 mm
  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world
Send Enquiry

Company Information

  • Member Since 6 Years
  • Nature of Business Retailer

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Dual channel, LCD display
  • Pre-selection of flame sizes
  • A flameout protection device
  • K and Na testing at the same time

Applications:

  • Flame Photometer is used for analyzing & measuring the content & concentration of K, Na elements
  • Testing cement, glass, ceramics, refractory materials and other construction materials
  • Testing fertilizers and soil
  • Testing products of mining, petroleum, metallurgy, and chemicals
  • Testing pharmaceutical, beverages and other food
    MSW testing
  • Various laboratory tests for scientific research, health, education and other fields

Technical Specifications:

SFP-40: With air-compressor.Measurement Range: K: 0-15, 0-40 μg/ml; Na: 0-40, 0-80 μg/ml

SFP-60: With air-compressor. Measurement Range: K: 0-15, 0-40, 0-60 μg/ml; Na: 0-40, 0-80, 0-120 μg/ml

SFP-100: With air-compressor, micro-printer or PC software. Measurement Range: K: 0-15, 0-40, 0-60, 0-100 μg/ml; Na: 0-40, 0-80, 0-120, 0-160 μg/ml

Linearity Range K: detection limit ≤ 0.004 mmol/lt.; Na: detection limit ≤ 0.008 mmol/lt.
Linearity Error K: ≤ 0.005 mmol/lt. (0.0100-0.0800) mmol/lt.; Na: ≤ 0.03 mmol/lt. (0.0500-0.400) mmol/lt.
Repeatability: Conduct 7 consecutive independent tests for one standard solution, the relative standard
deviation: ≤ 3%.
Stability: Continuous sampling of standard solution, the biggest change in the relative volume in 15 sec: ≤ 3%; Test once every minute, and test 6 times in total, the biggest change in the relative volume: ≤ 15%.



Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Flame Photometer?

Quantity
Seller Contact Details

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Flame Photometer at Best Price in Noida - ID: 4284114 | Feeniks Technologies
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Flame Photometer

Listing ID #4284114

  • Response Time<8 sec
  • Weight18 Kg
  • Dimension380 x 770 x 570 mm
  • Suction Jet of Samples<6ml/min
  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world
Send Enquiry

Company Information

  • Member Since 6 Years
  • Nature of Business Retailer

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Dual channel, LCD display
  • Pre-selection of flame sizes
  • A flameout protection device
  • K and Na testing at the same time

Applications:

  • Flame Photometer is used for analyzing & measuring the content & concentration of K, Na elements
  • Testing cement, glass, ceramics, refractory materials and other construction materials
  • Testing fertilizers and soil
  • Testing products of mining, petroleum, metallurgy, and chemicals
  • Testing pharmaceutical, beverages and other food
    MSW testing
  • Various laboratory tests for scientific research, health, education and other fields

Technical Specifications:

SFP-40: With air-compressor.Measurement Range: K: 0-15, 0-40 μg/ml; Na: 0-40, 0-80 μg/ml

SFP-60: With air-compressor. Measurement Range: K: 0-15, 0-40, 0-60 μg/ml; Na: 0-40, 0-80, 0-120 μg/ml

SFP-100: With air-compressor, micro-printer or PC software. Measurement Range: K: 0-15, 0-40, 0-60, 0-100 μg/ml; Na: 0-40, 0-80, 0-120, 0-160 μg/ml

Linearity Range K: detection limit ≤ 0.004 mmol/lt.; Na: detection limit ≤ 0.008 mmol/lt.
Linearity Error K: ≤ 0.005 mmol/lt. (0.0100-0.0800) mmol/lt.; Na: ≤ 0.03 mmol/lt. (0.0500-0.400) mmol/lt.
Repeatability: Conduct 7 consecutive independent tests for one standard solution, the relative standard
deviation: ≤ 3%.
Stability: Continuous sampling of standard solution, the biggest change in the relative volume in 15 sec: ≤ 3%; Test once every minute, and test 6 times in total, the biggest change in the relative volume: ≤ 15%.



Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for Flame Photometer?

Quantity
Seller Contact Details

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice