Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    Energy Measurement Module

    • Voltage drop during Power ON0.4 V or less
    • +/-3.45V  ( i.e. 1.5 % of rated voltage 230 V )Current
    • Communication Port :2 wire RS485
    • DIN rail mountingSize
    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 16 Years
    • building Nature of Business Retailer

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • +/- 2 % of Full Scale  ( 230V * 5A * CT ratio )Measurable Frequency range
    • 10% to 90% (Non condensing)Mounting
    • -20° to 80° CHumidity
    • 4 mALogic ‘0’ Voltage 
    •  Number of inputs
    •  Operating
    • 12 to 28 VDC 
    • Level 3 as per IEC1000-4-6Emissions
    • 24 VDC (Max : 28 VDC)Input Impedance
    • Level 3 as per IEC1000-4-4Immunity to Radiated RF
    • 5.6 kWRated Input Current
    • Communication Port :2 wire RS485
    • 100 W x 70 H x 35 D mmImmunity to ESD
    • Maximum Load current500 mA
    • +/-3.45V  ( i.e. 1.5 % of rated voltage 230 V )Current
    • Voltage drop during Power ON0.4 V or less
    • 0 to 5 VDCLogic ‘1’ Voltage
    • Number of Outputs4 (NPN Transistor)
    • +/- 2 % of Full Scale 5A * CT ratio.  Active Power
    • Level 3 as per IEC1000-4-3Immunity to Conducted RF
    • Power :+10 to +30 VDC
    • Number of Inputs3 phase alternating current and voltage input
    • Level 3 as per IEC1000-4-2Immunity to Transients
    • 0° to 60° CStorage
    • 4Rated Input Voltage
    • DIN rail mountingSize
    • 40Hz to 70Hz 
    •  Single Phase Voltage

     Features

    Low cost compact 3 phase Energy measurement module

    3 phase voltage input up to 300 Vrms (Line-Neutral) and current input up to 5 A can be measured

    Measures Voltage, Current, Frequency, Active Power, Reactive Power, True Power, Average Power and Power Factor

    Facility for 4 bi-directional digital inputs and 4 digital NPN outputs (open collector)

    High Speed Modbus RTU (Slave) communication

    2 wire RS-485 Communication port (isolated) on pluggable terminal block

    User definable Address, Baud rate and Parity through convenient DIP Switches

    LED indication for each Input and Output, COM port and Power ON

    No configuration software required

    Function
    FIOD-EN-0404-C measures 3 phase Energy and adds digital capability to a PLC / SCADA system.The module has 3 phase isolated Voltage and Current inputs . It also has 4 digital inputs and 4 digital outputs that can be read and controlled by the Modbus master. The digital inputs and outputs are isolated from the host device. The module has one RS485 (2 wire) communication port to connect to the host device. Communication settings like baud rate, parity and station ID can be set by DIP switches.

    Communication with Host
    The module supports Modbus RTU (Slave) Protocol. It communicates with the Host through 2 wire RS 485 Network. In case of communication failure with Host, the user can configure watchdog time-out and failure mode for the outputs.



    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for Energy Measurement Module?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice