Electric Fully Automatic SCADA Automation Panels, for Constructional, Voltage : 110V

Listing ID #2486002

  • Automatic GradeFully Automatic
  • Power1-3kw
  • Driven TypeElectric
  • Warranty1year
  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world
View More Details
Send Enquiry

Company Information

  • Member Since 11 Years
  • Nature of Business Retailer
  • GST No. 05AMGPK0095D1ZF

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Automatic Grade Fully Automatic
  • Power 1-3kw
  • Driven Type Electric
  • Warranty 1year
  • Application Constructional
  • Voltage 110V

We are pleased to present the enclosed proposal for your consideration. We have included all the necessary equipment to give you a well-engineered and reliable “fully automatic pump automation control panels with SCADA” The System we have offered includes the best quality materials available in the International market, to give you the best quality, design and performance. Our technical expertise is always at your disposal to assist you in operating and maintaining systems for years to come.  
Description :
 Supply of  fully automatic pump automation control panels of different capacities having intelligent unit having ‘ Field  Programmable Logic Controllers  based, SCADA with HMI, digital display of all parameters  ie. Operated Pump Motor Start, Run, Control, Protect against faults automatically operated Control & Management System ’ for Supervisory control and Data Acquisition System at pumping water supply schemes as per specifications & suitable for integration in the existing system.
Capacity : 25 HP, 40 HP, 50 HP, 90HP, 75 HP & 100 HP.
Panel Features :
Panel to activate, operate, control & monitor on line the pumps & other related labeled at each of the ‘Local Stations’ from the ‘Central Control Station’. The satiations shall be accessed ,sequentially or at random, through GSM CUM GPRS MODEM the central control station by dialing on the computer at the central through an attached modem, Field Programmable Logic Controllers & connection established with the GSM CUM GPRS modem & FIELD Field Programmable Logic Controllers at the local station. Once a connection has between the central control & the local station immediately the local station its hardware & software system shall communicate the status of various monitored to the central control & displayed at the monitor screen there.
The software of the automation & dialing system shall be so designed that it is time to establish connection between the central & any of the local station normally shall not exceed 30 seconds after dialing . in case it is to be more the specify it in their offers while submitting technical details of the system offered.
Operational Features :
It shall be possible to activate, operate, control & monitor on line the pumps & other related equipments installed at each of the local stations from the central control station. Broadly the local stations shall be accessed, sequentially or at random through GSM CUM GPRS modem from the central control station by dialing on the computer at the central control station through an attached modem Field Programmable Logic Controllers  & connection established with the GSM CUM GPRS modem & Field Programmable Logic Controllers at the local station. once a connection has been established between the central control & the local stations immediately the local station through its hardware & software system shall communicate the status of various parameters to be monitored to the central control & displayed at the monitor screen there.
The hardware & software of the automation & dialing system shall be so designed that it takes minimum time to establish connection between the central & any of the local stations, which normally shall not exceed 30 seconds after dialing. Its have following features :

  • Main unit (PLC) scanning speed 100 KHz.
  • 16 digital I/n & O/p.
  • 6 Analog input (12 bits adc).
  • 2 Analog output (12 bits).
  • 2 Nos. communication port (one RS232, RS485).
  • 1500 data register (D0 to D1500).
  • 255 No. timers .
  • 255 No. counter.
  • 1800 Digital Bits (M0 to M1800).
  • 100 No. type of instruction supportable & Easy to use.
  • Digital extension 32 I/P & 32 O/P.
  • Analog Extension 16/16 I/P, O/P.
  • Total analog input 38 Nos.
  • Total Analog output 34 Nos.


Note : Delta make HMI & SCADA easy to Interface. 
Pump Motor Protection Feature :

  • The panel shall provide following protections to the pump motor & shall trip the pump motor on occurrence of the fault.
    • Over Loading of MotorShort Circuit in the System Beyond the Panel Incoming
    • Earth Fault in the System Beyond the Panel Incoming
    • Under Voltage in the System
    • Over Voltage in the System
    • Phase Failure
    • Reverse Running of Motor
    • Dry Running of Pump
    • Unbalance of Voltage
    • Unbalance of Current Drawn By the Motor


Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry

Company Details close-icon

We are deals in supply & errection of lt side electrical equipments:
- vrp (precision pwm automatic voltage regulator with automatic bypass).
- servo voltage stabilisers oil / air cooled.
- distribution / power transformers upto 66 kv class.
-lt distribution panel.
-apfc.
-on line / off line ups.
-ac drives.
-automation in oil, gas, water & power sector.
-dozing pumps.
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
  • Number of Employees Below 20
  • Year of Establishment 2011
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for SCADA Automation Panels?

Quantity
Seller Contact Details

Find Seller from near by Cities

Browse Related Categories

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice