Company Information
Ask for more detail from the seller
Contact SupplierModel | Supply Voltage | Frequency Hz | Current A | Speed RPM | Max Air Flow CFM | Max Static Pressure | Capacitor μF | |
Pa | mm of H2O | |||||||
CB 1255 W | Single Phase 110V | 60 | 0.9 | 2600 | 240 | 300 | 30 | 6 |
CB 1255 X | Single Phase 230V | 50 | 0.4 | 2600 | 240 | 285 | 29 | 1.85 |
CB 1255 Y | Three Phase 230V | 60 | 0.5 | 2600 | 240 | 300 | 30 | - |
CB 1255 Y | Three Phase 415V | 50 | 0.2 | 2600 | 240 | 285 | 29 | - |
Wiring Diagram for Single Phase Blower
Ensure that impeller is rotating in counter clockwise direction. Airflow is maximum.
Short Black wires & connect the capacitor as shown. To change the direction, connect the supply wire from White to Red.
Red wires are for running winding & Black wires are for starting winding. To Change the direction, interchange Black wire or Red wire.
To Change the direction, interchange any two wires between U, V & W. For 415 V supply, wires are connected in Star configuration. Short White, Black & Blue wire & then insulate properly