Listing ID #2014647
Company Information
Ask for more detail from the seller
Contact SupplierResistivity (geo-electrical) surveying is one of the most versatile and successful geophysical prospecting methods for mineral prospecting, ground resistance measurements, geological and geo-technical mapping, bedrock studies, certain civil engineering applications and also for ground water prospecting.
The Aquameter's intelligent microprocessor technology employs ingenious methods for extracting subsurface information. It is a popular instrument, because of its single button operation, deep penetration, accurate and reliable results, even in adverse field conditions. The instrument has a facility to measure self potential (SP) which is useful in mineral prospecting and environmental studies.
Aquameter CRM - 20 : Low power version (4W) suitable for high resistivity soil.
Aquameter CRM 500 : High power version (40 W) suitable for saline & marshy terrain.
Aquameter CRM AT : It is in it's final stages of development. Essentially it is a more advanced version of CRM 500.
Key Features
Applications of Earth Resistivity Meter
A complete information of the instrument, it's field operation and guidelines about interpretation of the data are provided. A full guarantee for a period of 1 year against any manufacturing defects is given on all products.
Selectable Constant Current | 0.2, 0.5, 1, 2, 5, 10, 20 mA |
---|---|
Voltage max | 150 V ( 300 Vpp) |
Power | 4 W |
Input impedance | 10 M Ohms |
Input range | 0 - 100 V |
Precision | +/- 0.001 V |
Noise rejection: | 95 db at 50 - 60 Hz. |
DV/I ranges | 1 Ohm, 100 Ohm, 10k Ohm, 1 M Ohm |
DV/I precision | +/- 0.001 ( 1 Ohm range, 20 mA ) |
Cycle time: | 4 Seconds |
Accuracy | 2% + precision |
Diagnostic display system | 9 Codes |
Temperature range (operating) | 0 - 50 degrees C |
Power source | 12 V rechargeable battery pack |
Measuring capacity | 3000 - 4000 single cycle readings |
Weight | 10.5 kg |
Dimensions | L 350 mm x W 150 mm x H 365 mm |
Selectable Constant Current | 5, 10, 20, 50, 100, 250, 500 mA |
---|---|
Voltage max | 500 V ( 1000 Vpp) |
Power: | 40 W |
Input impedance | 10 M Ohms |
Input range | 0 - 200 V |
Precision: | +/- 0.05 mV |
Noise rejection | 95 db at 50 - 60 Hz. |
DV/I ranges | m Ohm, Ohm, k Ohm |
DV/I precision | +/- 0.02 m Ohm at 500 mA |
Cycle time | 6 Seconds |
Accuracy | 2% + precision |
Diagnostic display system | 9 Codes |
Temperature range (operating) | 0 - 50 degrees C |
Power source | 12 V rechargeable battery pack |
Measuring capacity | 200 readings at 500 mA |
Weight | 12.5 kg |
Dimensions | L 400 mm x W 225 mm x H 330 mm |