Technical data savina
ventilation modes – ippv (cmv), ippvassist (cmvassist)
simv, simvasb (simv/ps)
cpap, cpapasb (cpap/ps)
bipap1), (pcv+) (optional), bipap1)asb (pcv+/ps) (optional)
enhancements – niv – non invasive ventilation with optimized alarm system and automatic leakage compensation (optional)
autoflow® – automatic adaptation of the inspiratory flow in volume
orientated ventilation modes (optional).
lpo - low pressure oxygen. Independant oxygen supply,
e.g. With an o2 concentrator (optional)
graphic screen - advanced ventilation monitoring (optional),
nurse call - connection for transmitting alarm signals to a central
patient type adult, pediatric
ventilation frequency 2 to 80 bpm
inspiration time 0.2 to10 s
tidal volume 0.05 to 2.0 l, btps2)
inspiratory flow 0 to180 l/min
inspiratory pressure 0 to 99 mbar 3) (cmh2o)
peep/interm. Peep 0 to 35 mbar (cmh2o)
pressure support/asb 0 to 35 mbar (cmh2o) (relative to peep)
flow acceleration 5 to 200 mbar/s (cmh2o/s)
o2-concentration 21 to100 vol. %
trigger sensitivity 1 to15 l/min
measured value display
airway pressure peak pressure, plateau pressure, mean airway pressure,
measurements peep 0 -100 mbar (cmh2o)
minute volume (mv) total mv, spontaneous mv 0 to 99 l/min, btps
tidal volume vt inspiratory vt, expiratory vt 0 to 3999 ml, btps
breathing frequency total and spontaneous breathing frequency, 0 -150 bpm
inspiratory o2-concentration 21 to100 vol. %
breathing gas temperature 18 to 48 °c (sensor optional)
curve displays airway pressure / time, flow / time
ventilation ratio (i:e) 150:1 to 1:150
alarms
airway pressures high / low
expiratory minute volume high / low
tidal volume high / low
apnea-alarm time 15 to 60 sec
spontaneous breathing frequency high
inspiratory o2-concentration high / low
inspiratory breathing gas temperature high
performance data
maximum flow for pressure assist/spontaneous breathing 180 l/min
valve response time t0…90 ≤ 5 ms
control principle time-cycled, volume-constant, pressure- controlled
safety valve opening pressure 100 mbar (cmh2o)
emergency valve automatically enables spontaneous breathing with filtered ambientair if air o2and o2 supply should fail.
automatic gas switch-over function if supply fails
output for pneumatic medicament nebulizer synchronized with inspiration operating data
main power connection 100 v to 240 v, 50/60 hz ac, 10 to 36 v dc
typical power consumption 100 w
internal battery approx. 60 min (optional extension up to 7 h)
digital machine outputs
digital output and input via an rs 232 c interface,
dräger medibus standard
gas supply
air turbine technology
o2 gas supply 3 bar (39 psi) to 10 % up to 6 bar (87 psi).
dimensions and weights
dimensions w x h x d (without trolley) 380 x 383 x 358 mm (15.0 x 156.1 x 14.1 inches)
weight (basic device) approx. 24 kg (53 lbs.)
diagonal screen size 6.1" tft color screen
bipap – trademark used under licence
btps – body temperature pressure saturated. Measured values relating to the conditions of the patient lung, body temperature 37 °c, steam-saturated gas,
ambient pressure.
3) 1 mbar = 100 pa, autoflow®, trademark by dräge