    Drager Savina Ventilator

    • MOQ1 Piece(s)
    • Brand NameDrager
    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world

    We are ofering drager savina ventilator. Technical data savina ventilation modes – ippv (cmv), ippvassist (cmvassist) simv, simvasb (simv/ps) cpap, cpapasb (cpap/ps) bipap1), (pcv+)....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 19 Years
    • building Nature of Business Retailer
    • Year of Establishment 1995

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    We are ofering drager savina ventilator.
    Technical data savina
    ventilation modes – ippv (cmv), ippvassist (cmvassist)
    simv, simvasb (simv/ps)
    cpap, cpapasb (cpap/ps)
    bipap1), (pcv+) (optional), bipap1)asb (pcv+/ps) (optional)
    enhancements – niv – non invasive ventilation with optimized alarm system and automatic leakage compensation (optional)
    autoflow® – automatic adaptation of the inspiratory flow in volume
    orientated ventilation modes (optional).
    lpo - low pressure oxygen. Independant oxygen supply,
    e.g. With an o2 concentrator (optional)
    graphic screen - advanced ventilation monitoring (optional),
    nurse call - connection for transmitting alarm signals to a central
    patient type adult, pediatric
    ventilation frequency 2 to 80 bpm
    inspiration time 0.2 to10 s
    tidal volume 0.05 to 2.0 l, btps2)
    inspiratory flow 0 to180 l/min
    inspiratory pressure 0 to 99 mbar 3) (cmh2o)
    peep/interm. Peep 0 to 35 mbar (cmh2o)
    pressure support/asb 0 to 35 mbar (cmh2o) (relative to peep)
    flow acceleration 5 to 200 mbar/s (cmh2o/s)
    o2-concentration 21 to100 vol. %
    trigger sensitivity 1 to15 l/min
    measured value display
    airway pressure peak pressure, plateau pressure, mean airway pressure,
    measurements peep 0 -100 mbar (cmh2o)
    minute volume (mv) total mv, spontaneous mv 0 to 99 l/min, btps
    tidal volume vt inspiratory vt, expiratory vt 0 to 3999 ml, btps
    breathing frequency total and spontaneous breathing frequency, 0 -150 bpm
    inspiratory o2-concentration 21 to100 vol. %
    breathing gas temperature 18 to 48 °c (sensor optional)
    curve displays airway pressure / time, flow / time
    ventilation ratio (i:e) 150:1 to 1:150
    alarms
    airway pressures high / low
    expiratory minute volume high / low
    tidal volume high / low
    apnea-alarm time 15 to 60 sec
    spontaneous breathing frequency high
    inspiratory o2-concentration high / low
    inspiratory breathing gas temperature high
    performance data
    maximum flow for pressure assist/spontaneous breathing 180 l/min
    valve response time t0…90 ≤ 5 ms
    control principle time-cycled, volume-constant, pressure- controlled
    safety valve opening pressure 100 mbar (cmh2o)
    emergency valve automatically enables spontaneous breathing with filtered ambientair if air o2and o2 supply should fail.
    automatic gas switch-over function if supply fails
    output for pneumatic medicament nebulizer synchronized with inspiration operating data
    main power connection 100 v to 240 v, 50/60 hz ac, 10 to 36 v dc
    typical power consumption 100 w
    internal battery approx. 60 min (optional extension up to 7 h)
    digital machine outputs
    digital output and input via an rs 232 c interface,
    dräger medibus standard
    gas supply
    air turbine technology
    o2 gas supply 3 bar (39 psi) to 10 % up to 6 bar (87 psi).
    dimensions and weights
    dimensions w x h x d (without trolley) 380 x 383 x 358 mm (15.0 x 156.1 x 14.1 inches)
    weight (basic device) approx. 24 kg (53 lbs.)
    diagonal screen size 6.1" tft color screen
    bipap – trademark used under licence
    btps – body temperature pressure saturated. Measured values relating to the conditions of the patient lung, body temperature 37 °c, steam-saturated gas,
    ambient pressure.
    3) 1 mbar = 100 pa, autoflow®, trademark by dräge


    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for Drager Savina Ventilator?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice