Listing ID #208344
Company Information
Ask for more detail from the seller
Contact SupplierWe manufacture clinical flame photo meters which are popular due to their excellent quality; utilization of fine quality raw material and top notch technology keep on fueling their craze. Our experts and engineers and supervisors have enough knowledge of the market to prepare properly updated and standard products. High durability, long existence, innumerable designs, standard market rates keep on increasing their demands.
Specification:
model s-932
range na: 0-200 meql ca: 0-2 meql k : 0-100 meql li: 0-10 meql
sensitivity sodium (na) : 5 ppm, potassium (k) : 5 ppm, calcium (ca) : 10 ppm (optional), lithium (li) : 10 ppm (optional)
readout dual 2 ½ digit bright red led display
accuracy + 2% upto 100 meql + 5% above 100 meql
ignition system with external lighter
dimensions 355w x 245h x 230dmm (approx. )
weight 7. 5 kg. (approx. )
measurement system measures one element at a time
repeatability ± 2 counts
detector silicon photodiode
filters narrow band interference glass filters
nebulizer black bakelite, axial flow type
flame system lpg and dry oil free air
warm up time 10 minutes
power 230 v± 10? ,50hz
compressor unit:
air supply by oil free mini compressor unit with pressure regulator
combustion gas lpg controlled by precision regulator
power 230v± 10? ,50hz
dimension 275w x192h x 240d mm
weight 6. 5kg. (approx)
accessories *instrument with na & k filters *sample holders *instruction manual * *air and gas tubing along with end clamps *chimney *capability tubes *cleaning wires.
Model | S-932 |
---|---|
Range | Na: 0-200 meq/l Ca: 0-2 meq/l K : 0-100 meq/l Li: 0-10 meq/l |
Sensitivity | Sodium (Na) : 5 ppm Potassium (K) : 5 ppm Calcium (Ca) : 10 ppm (Optional) Lithium (Li) : 10 ppm (Optional) |
Readout | Dual 2½ digit bright red LED display |
Accuracy | + 2% upto 100 meq/l + 5% above 100 meq/l |
Ignition System | With external lighter |
Dimensions | 355W X 245H X 230Dmm (Approx.) |
Weight | 7.5 Kg. (Approx.) |
Measurement System | Measures one element at a time |
Repetability | ± 2 Counts |
Detector | Silicon Photodiode |
Filters | Narrow band interference glass filters |
Nebulizer | Black bakelite, axial flow type |
Flame System | LPG and dry oil free air |
Warm Up Time | 10 minutes |
Power | 230 V± 10?,50HZ |
Air Supply | By oil free mini compressor unit with pressure regulator |
---|---|
Combustion | GAS LPG controlled by precision regulator |
Power | 230V± 10?,50Hz |
Dimension | 275W X192H X 240D mm |
Weight | 6.5kg. (Approx) |
Accessories | *instrument with Na & K Filters *Sample Holders *Instruction Manual * *Air and Gas Tubing along with End Clamps *Chimney *Capability Tubes *Cleaning Wires. |