Contact SupplierWe put forward Digital Clamp Meter DT-630, which are manufactured in compliance with the industry standards. These are procured from the reliable vendors and manufacturers based in various parts of India. Our screws are manufactured in compliance at the vendors’ facility using graded alloys. Further, our clients can avail these quality products at market leading prices.
Â
Â
Specification:
Function | Range | Accuracy | Resolution | Remarks | ||||
ACV | 400mV | 1.2% of rdg | 0.1mV | Overload protection: 1000V DC/750Vrms ACImpedance: 10MΩ,More than 100MΩ on 400mV scale | ||||
4V | 0.8% of rdg | 1mV | ||||||
40V | 10mV | |||||||
400V | 100mV | |||||||
1000V | 1.5% of rdg | 1V | ||||||
DCV | Range | Accuracy | Resolution | Frequency | Average sensing, calibrated to rms of sine waveOverload protection: 1000V DC/750Vrms AC
Impedance: 10MΩ. |
|||
400mV | ±2.5% of rdg | 0.1mV | 50~100Hz | |||||
4V | 1.2% of rdg | 1mV | ||||||
40V | 10mV | |||||||
400V | 100mV | |||||||
750V | 2.5% of rdg | 1V | ||||||
ACA | Range | Accuracy | Resolution | Overload protection: 1000Arms within 60 seconds | ||||
4000mA | 3.5% of rdg | 1mA | ||||||
30A | 3.0% of rdg | 10m A | ||||||
DCA | Range | Accuracy | Resolution | Frequency | Average sensing, calibrated to rms of sine waveOverload protection: 1000Arms within 60 seconds | |||
4000mA | 3.5% of rdg | 1mA | 50~60Hz | |||||
30A | 3.0% of rdg | 10m A | ||||||
Resistance | Range | Accuracy | Resolution | Overload protection: 250V DC/250Vrms AC | ||||
400Ω | 1.8% of rdg | 0.1Ω | ||||||
4kΩ | 1.2% of rdg | 1Ω | ||||||
40kΩ | 10Ω | |||||||
400kΩ | 100Ω | |||||||
4MΩ | 1kΩ | |||||||
40MΩ | 2.0% of rdg | 10kΩ | ||||||
Capacitance | Range | Accuracy | Resolution | Overload protection: 250V DC/250Vrms AC | ||||
40nF | 3.5% of rdg | 10PF | ||||||
400nF | 2.5% of rdg | 100PF | ||||||
4μF | 1nF | |||||||
40μF | 10nF | |||||||
100μF | 3.5% of rdg | 100nF | ||||||
Frequency | Range | Accuracy | Resolution | Sensitivity | Overload protection: 250V DC/250Vrms ACDuty cycle: 0.1%~99.9% | |||
10Hz | 0.5% of rdg | 0.01Hz | Range of input voltage:1.5V~10V, If input voltage over range, need adjust | |||||
100Hz | 0.1Hz | |||||||
1000Hz | 1Hz | |||||||
10kHz | 10Hz | |||||||
Temperature(NiCr-NiSi sensor) | Range | Accuracy | Resolution | Overload protection: 250V DC/250Vrms AC | ||||
℃ | -20~150℃ | 3℃+2 | <400℃ | 1℃ | ||||
150~300℃ | 3.0% of rdg | <400℃ | 1℃ | |||||
300~1000℃ | 3.5% of rdg | ≥400℃ | 1℃ | |||||
Diode and Audible continuity test | Range | Description | Test condition | Overload protection: 250V DC/250Vrms AC | ||||
Display read approx.Forward voltage of diode. | Forward DC currentapprox. 0.4mA
Reversed DC voltage approx. 1.5V |
|||||||
Built-in buzzer soundsif resistance is less
than 70Ω |