Company Information
Ask for more detail from the seller
Contact SupplierWe are hailing from Vadodara(India) and make sure to reach buyer's specific destination within the promised time frame. After the product is completely inspected, we make sure that it is sternly packed using the finest packaging material. Our team members ensure that the packaging keeps the products safe from external destructive factors. Features Easy to install unit CPCB II Compliant Low operating costs High reliability in extreme operating condition Compact design saves installation space thus construction cost Excellent smooth running characteristic Long service life Low maintenance requirements and legendary durability Worldwide distribution network Low emission ensure environmentally friendly operation.
Features
Genset Model | Engine Model | Generator Output | Engine Output (bHp) | Number Of Cylinder | Aspiration | Governor | Engine Displacement (liters) | Rated Current (Amps) | IN-Built Fuel Tank Capacity (liters) | Acoustic Enclouser Dimensions (L (mm) x W (mm) x H (mm)) | Approx. Weight (Kgs.) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
KVA | KWE | |||||||||||
PKGVPII-250 | TAD754GE | 250 | 200 | 295 | 6 in line | TC | Electronic / Class G3 | 7.15 | 348 | 500 | 4000 x 1600 x 2100 | 3800 |
PKGVPII-320 | TAD1351GE | 320 | 256 | 373 | 6 in line | TC | Electronic / Class G3 | 12.78 | 445 | 990 | 5000 x 1910 x 2470 | 5200 |
PKGVPII-380 | TAD1354GE | 380 | 304 | 445 | 6 in line | TC | Electronic / Class G3 | 12.78 | 529 | 990 | 5400 x 1910 x 2470 | 6100 |
PKGVPII-400 | TAD1355GE | 400 | 320 | 479 | 6 in line | TC | Electronic / Class G3 | 12.78 | 556 | 990 | 5400 x 1910 x 2470 | 6200 |
PKGVPII-500 | TAD1651GE | 500 | 400 | 585 | 6 in line | TC | Electronic / Class G3 | 16.12 | 696 | 990 | 5400 x 1910 x 2470 | 6400 |
PKGVPII-600 | TWD1652GE | 600 | 480 | 687 | 6 in line | TC | Electronic / Class G3 | 16.12 | 835 | 990 | 5600 x 1910 x 3440 | 6650 |
PKGVPII-650 | TWD1653GE | 650 | 520 | 744 | 6 in line | TC | Electronic / Class G3 | 16.12 | 904 | 990 | 5600 x 1910 x 3440 | 6790 |
Genset Model | Engine Model | Generator Output kVA kWe | Engine Output kWm bHp | Number of Cylinders | Aspiration | Governor | Engine Displacement (liters) | Rated Current (amps) | In-Built Fuel Tank Capacity (liters) | Acoustic Enclosure Dimensions L (mm) x W (mm) x H (mm) | Approx. Weight (Kgs.) | ||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|
PKGES-10 | G15-II | 10 | 8 | 16.1 | 21.6 | 2 | NA | Mechanical / A1 | 1.56 | 13.9 | 35 | 1765 x 900 x 1355 | 690 |
PKGES-15 | G15-II | 15 | 12 | 16.1 | 21.6 | 2 | NA | Mechanical / A1 | 1.56 | 20.87 | 35 | 1765 x 900 x 1355 | 700 |
PKGES-20 | G20-II | 20 | 16 | 18.6 | 25 | 3 | NA | Mechanical / A1 | 2.15 | 27.82 | 65 | 2155 x 940 x 1250 | 880 |
PKGES-25 | G25-II | 25 | 20 | 25.1 | 33.6 | 3 | TCI | Mechanical / A1 | 2.15 | 34.78 | 65 | 2400 x 1040 x 1400 | 950 |
PKGES-30 | G30-II | 30 | 24 | 31.3 | 42 | 3 | TCI | Mechanical / A1 | 2.15 | 41.74 | 65 | 2400 x 1040 x 1400 | 950 |
PKGES-35 | G40-II | 35 | 28 | 31.3 | 42 | 3 | TCI | Mechanical / A1 | 2.15 | 48.69 | 65 | 2400 x 1040 x 1400 | 965 |
PKGES-40 | G40-II | 40 | 32 | 39.4 | 52.8 | 4 | TCI | Mechanical / A1 | 2.86 | 55.65 | 90 | 2500 x 1040 x 1400 | 1050 |
PKGES-45 | G40-II | 45 | 36 | 39.4 | 52.8 | 4 | TCI | Mechanical / A1 | 2.86 | 62.61 | 90 | 2500 x 1040 x 1400 | 1050 |
Notes : Standard Gensets are available in Radiator cooling. l Alternators : Self excited with Class H insulation, IP23 protection, 1500 rpm, 50Hz, 3 phase, 0.8 pf, 415 V, Single Phase option available upto 40 kVA. l As a process of continual improvement, above data is subjected to change.
Legend : l NA-Naturally Aspirated l TC-Turbocharged l TCI-Turbocharged with Intercooler. | * The height of Genset is excluding the Silencer. | For any further queries contact Sales Department.
Genset Model | Engine Model | Generator output kVA kWE | Engine Output Bhp | Number of Cylinders | Aspiration | Governor | Engine Displacement (liters) | Rated Current (Amps) | In-Built Fuel Tank Capacity (liters) | Acoustic Enclosure Dimensions L (mm) x W (mm) x H (mm) | Approx. Weight (Kgs.) | |
---|---|---|---|---|---|---|---|---|---|---|---|---|
PKGGC-62.5 | 4G11TAG22 | 62.5 | 50 | 101.3 | 4 | TCI | Mechanical / A1 | 4.5 | 87 | 125 | 2685 x 1080 x 1455 | 1480 |
PKGGC-82.5 | 4G11TAG23 | 82.5 | 66 | 126.6 | 4 | TCI | Mechanical / A1 | 4.5 | 114.3 | 150 | 3100 x 1200 x 1575 | 1525 |
PKGGC-100 | 4G11TAG23 | 100 | 80 | 126.6 | 4 | TCI | Mechanical / A1 | 4.5 | 139.1 | 150 | 3100 x 1200 x 1575 | 1550 |
PKGGC-125 | 4G11TAG24 | 125 | 100 | 155 | 4 | TCI | Mechanical / A1 | 4.61 | 173.9 | 200 | 3400 x 1300 x 1800 | 1640 |
PKGGC-160 | 6G11TAG24 | 160 | 128 | 243.1 | 6 | TCI | Mechanical / A1 | 6.91 | 222.6 | 260 | 3800 x 1400 x 1770 | 2100 |
PKGGC-180 | 6G11TAG24 | 180 | 144 | 243.1 | 6 | TCI | Mechanical / A1 | 6.91 | 250.4 | 320 | 3800 x 1400 x 1770 | 2150 |
PKGGC-200 | 6G11TAG24 | 200 | 160 | 243.1 | 6 | TCI | Mechanical / A1 | 6.91 | 278.2 | 320 | 3800 x 1400 x 1770 | 2200 |
PKGGC-250 | 6G11TAG25 | 250 | 200 | 313 | 6 | TCI | Electronic / A1 | 7.31 | 347.8 | 500 | 4000 x 1700 x 1950 | 2780 |
PKGGC-320 | 12V14TAG23 | 320 | 256 | 604 | 12 | TCI | Electronic / A1 | 16.83 | 445.2 | 650 | 5500 x 1910 x 2340 | 4900 |
PKGGC-400 | 12V14TAG23 | 400 | 320 | 604 | 12 | TCI | Electronic / A1 | 16.83 | 556.5 | 800 | 5500 x 1910 x 2340 | 5130 |
PKGGC-500 | 12V14TAG23 | 500 | 400 | 604 | 12 | TCI | Electronic / A1 | 16.83 | 695.6 | 990 | 5500 x 1910 x 2340 | 5260 |
Notes : Standard Gensets are available in Radiator cooling. l Alternators : Self excited with Class H insulation, IP23 protection, 1500 rpm, 50Hz, 3 phase, 0.8 pf, 415 V, Single Phase option available upto 40 kVA. l As a process of continual improvement, above data is subjected to change.
Legend : l NA-Naturally Aspirated l TC-Turbocharged l TCI-Turbocharged with Intercooler. | * The height of Genset is excluding the Silencer. | For any further queries contact Sales Department.