Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

DG Synchronization Panel

Listing ID #3743875

  • TypeFixed , drawout ,compartmentalized ,dust & vermin proof
  • SHORT CIRCUIT LEVEL35 KA / 50 KA /70KA for 1 sec
  • BUS CHAMBERAir cooled with louvers
  • BUSBARAluminium / Copper, Electrolytic grade
  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world
View More Details
Send Enquiry

Company Information

  • Member Since 6 Years
  • Nature of Business Retailer

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Type Fixed , drawout ,compartmentalized ,dust & vermin proof
  • STANDARD IS 8623
  • RATED VOLTAGE Std. 415 / 440 V, 50 HZ, 3 phase, 4 wire
  • SHORT CIRCUIT LEVEL 35 KA / 50 KA /70KA for 1 sec
  • BUSBAR Aluminium / Copper, Electrolytic grade
  • CABLE ENTRY Top or Bottom
  • ENCLOSURE TYPE Indoor / Outdoor
  • BUSBAR SUPPORT SMC/DMC, Epoxy.
  • RATED CURRENT Upto 6000A main busbar rating
  • CABLE ALLEY Ample space for cabling with supports
  • SYNCHRONIZING Auto changeover & transfer . Auto Synchronizing/parelleling of DG sets Auto loads sharing (KW/KVAR) Load dependent start stop
  • PROTECTION CLASS IP42 / IP 54 – Optional
  • BUS CHAMBER Air cooled with louvers

We are the pioneers in introducing PLC based DG synchronization panels to the Electrical panel industry in northern region .With years of experience and on site troubleshooting/diagnosis capabilities we have designed our DG synchronization panel with great care , consider ing the protection of DG sets and associated switchgear for optimum workability .
It is used to supply DG set power in absence of main power. It comprises of control of DG set as well as switching of breakers. In absence of main source it starts the first DG set & synchronizes with the second DG set automatically along with auto load(KW/KVAR) sharing , the same procedure is followed with balance DG sets as per load demand . The DG sets are switched ON & OFF as per the load requirement . On restoration of Grid Power , DG ACB’s are tripped and Load is transferred to Grid power. DG sets remain in running condition for a specific cooling time as specificed by generator manufacturer and subsequently DG sets are shutdown.



Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry

Company Details close-icon

We, at TRINITRON have a single minded approach to bring excellence to the field of Panel Manufacturing and our years of experience have brought us close to all the customers. We seek to be with them, in their small needs and big leaps, sharing our knowledge and experience. Thereby, giving them the confidence to achieve their goals.
For us the efforts are worth the rewards, is the satisfaction of our MOST VALUED CUSTOMERS.
Found in 1983 as a small company with a big vision.
Maintained a phenomenal growth over the years.
Achieved financial stability gradually and grown based on ethics and knowledge
Consistent record of over 80% of business coming from repeated customers.
Known in the market for delivery records of many successful project deliveries over the years.
Associated with Leading Switchgear / automation product manufacturers across the globe.
A dedicated team of brilliant professionals.
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for DG Synchronization Panel?

Quantity
Seller Contact Details

Find Seller from near by Cities

Browse Related Categories

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice