Contact SupplierProduct Features
With Delta's cutting-edge technology, the commercial series Solar Inverters are with efficiencies as high as 98.3%. These inverters are compact in size with durable quality to ensure smooth PV system operation. IP65 enclosure provides higher level of protection and enhances its durability in a harsh outdoor environment.
Notes
Input (DC) | RPI-M10A |
---|---|
Recommended Max. DC Power | 12.5 kWp |
Max. Input Voltage | 1000 V |
DC Voltage Range | 200 - 1000 V |
Start-up Voltage | >250 V |
Start-up Power | 40W |
MPPT Voltage Range | 200 - 1000 V |
MPP Voltage Range, Full Power | 415 - 800 V |
Nominal DC Voltage | 600 V |
Max. Input Current per MPPT | 15 A / 10 A |
Total Input Current | 25 A |
Maximum Short Circuit Current | 19.5A / 13A |
No. of Independent MPP Trackers | 2 |
Unbalanced Input (%) | 60 / 40 |
Input Connection Type | 3 pair MC4 |
DC Disconnection Switch | Yes (Inbuilt) |
Output (AC) | |
Rated Output Power | 10 kVA |
Maximum Output Power | 10.5 kVA |
Rated Output Current | 14.5 A |
Max. Output Current | 16 A |
Inrush Current | 31A / 100μs |
Nominal AC Voltage | 3 Ph, 400 V |
AC Voltage Range | 400 V ± 20 % (320~480) |
Nominal Frequency | 50 Hz |
Frequency Range | 45 Hz - 55 Hz |
Power Factor at Rated Power | Unity |
Reactive Power (Adjustable) | 0.8 Lagging ~ 0.8 Leading |
Harmonics | <3% at Rated Power |
DC Injection | <0.5% at Rated Output Current |
No. of Conductors (user settable) | 4/5 Wire (L1, L2, L3, N, PE) |
Efficiency | |
Maximum Efficiency | 98.30% |
Euro Efficiency | 98% |
Protection | |
Input-side Disconnection Device | Yes |
Ground fault monitoring / Grid monitoring | Yes |
DC reverse polarity protection | Yes |
DC Over Voltage / Current Limitation Protection | Yes |
DC Short Circuit Protection Yes, PV Fuse - 1000V, 15A AC Short Circuit Protection | Yes |
AC Over Voltage / Current Limitation Protection | Yes |
DC / AC Side Surge Protection – Inbuilt | Yes, MOV |
Safety/Standards | |
Anti-islanding Protection / Grid Regulation | VDE-AR-N 4105:2011 ; DIN VDE V 0124-100:2012; DIN VDE V 0126-1-1; IEC 61727; IEC 62116 |
EMC | DIN VDE V 0124-100:2012; DIN VDE V |
Safety | 0126-1-1; IEC 61727; IEC 62116 |
Efficiency | IEC 61683:1999 |
Environmental Testing | IEC 60068-2 (1,2,14,30) |
Ingress Protection | IEC 60529 |
Communication | |
Communication Interface | MODBUS RTU over RS 485 Physical Layer |
Display | 20 x 4 LCD |
Built-in Energy Data Logger | Yes |
Emergency Power Off (EPO) | Yes, External Switch to be Connected |
Warranty | |
Standard Warranty | 5 Years |