Contact SupplierOLL PD 2000
We offer defibrillator, which in used in delivering a therapeutic dose of electrical energy to the affected heart. The defibrillator helps critical mass of the heart muscle, terminates the arrhythmia, and allows normal sinus rhythm to be reestablished by the body's natural pacemaker. The types of defibrillator we offer are:
Zoll PD 2000
The ZOLL PD 2000 Advisory Defibrillator/Pacemaker is the first device designed as a completely integrated system for early defibrillation and advanced cardiac life support in the hospital. The built-in ventricular fibrillation detection system eliminates adapters and a "paddlefree" electrode system is easily applied to speed shockdelivery and external pacing. Standardized controls make it ideal for the hospital planning implementation of early defibrillation to improve outcomes from cardiac arrest. This small and lightweight unit is the most versatile hospital defibrillation system available today. The PD 2000 is equally suited for general floor use by noncritical care BLS trained staff and ACLS code teams for defibrillation, external pacing and transport. New state-of-the-art modular AC power and rapid battery recharging allow the PD 2000 to meet the needs of every hospital area. Its easily exchangeable low cost lead acid battery system provides unequaled crash-cart uptime and improved quality in device maintenance and readiness. No other unit provides a hospital with the inherent flexibility of the ZOLL PD 2000 Advisory Defibrillator/Pacemaker.
Features :
Innovative features :
Large Monitor
Non-fade monitor.
ECG monitor.
Strip recorder.
AC power supply for stationary use.
Specifications:
Pacemaker
Type: VVI demand; asynchronous (fixed rate)
when used without ECG leads.
Pulse Type: Rectilinear, constant current.
Pulse Duration: 40 milliseconds.
Pulse Amplitude: Variable to 140 mA.
Pacing Rate: Variable from 30 to 180 PPM.
Output Protection: Fully defibrillator-protected and isolated.
Pacer On: Message display on monitor.
Defibrillator :
Waveform: Damped sinusoid.
Output Energy
Delivered: Selectable at 2, 3, 5, 7, 10, 20, 30, 50,100, 150, 200, 300, 360 joules.
Charge Time: Less than 10 seconds.
Delivered Energy
Display: CRT monitor displays delivered energy.
Synchronized Mode: Synchronizes defibrillator pulse to patient’s R-wave. “SYNC” message
displayed on monitor. Marker on monitor and on recorder paper identifies R-wave.
Internal Paddles: Output limited to 50 joules when internal paddles are connected. Discharge from paddles.
Charge Controls: Control on apex paddle and front panel.
Paddles: Standard paddles are anterior/anterior adult and pediatric. Adult paddles slide off to expose pediatric paddles.
Defibrillation Electrodes: Specifically designed ZOLL Multi- Function Electrodes used in anterior/anterior or anterior/posterior positions; packaged in pairs.
Integral Defibrillator Tester: Integral circuitry allows complete test of defibrillator charge and discharge without removing paddles from storage wells.
Identical circuitry allows complete test of unit configured with multifunction cable.
Defib On: Message display on monitor.
Monitor and Display
Patient Connection: Via 3-lead ECG cable, paddles, and elec trodes. Selectable by front panel switch.
Input Protection: Fully defibrillator-protected. Special circuit prevents distortion of ECG by pacer pulse.
Bandwidth: .5 – 40 Hz (–3dB) standard.
Display Format: Nonfade, moving trace with freeze capability
Monitor On: Message display on monitor.
Screen Type: High-resolution CRT display.
Screen Size: 5 inches diagonally (108 mm x 85 mm viewing area).
Sweep Speed: 25 mm/sec.
Viewing Time: 4 seconds.
Heart Rate: Digital display on monitor 0 – 300 BPM.
Pacer Output Current: Digital display on monitor 0 –140 mA.
ECG Lead Selection: Display on monitor.
ECG Size: .5, 1, 2 cm/mV display on monitor.
Alarm On/Off Status: Display on monitor. User selectable
High (60 – 280 BPM)
Low (20 – 100 BPM).
ECG Lead Off: Message display on monitor.
Pacer Electrode Off: Message display on monitor.
Defibrillator Paddle Fault: Message display on monitor.
Defibrillator Electrode Fault: Message display on monitor.
Recorder Paper Out: Message display on monitor.
Low Battery Voltage: Message display on monitor.