Company Information
Ask for more detail from the seller
Contact SupplierWe are offering ir type damaged belt detector.
Many a times in normal running, some sharp objects gets locked in the chute plate. This sharp object cuts the belt surface and material start falling down the belt. To detect this damage protocontrol offers infrared type damaged belt detector.
infrared type light beam curtain is fixed below the belt. In the case of belt damage, material pieces or dust starts falling down through the belt slit. When the light beams are obstructed by falling material through conveyor, same is detected and alarm is activated. Special electronic circuit for use in dusty environment is developed by protocontrol.
specification of series dbd i:
sensing unit:
sensing area approx: length 350 mm
sensing gap (belt width): 1.5 mtr.
enclosure for sensing unit: al
control unit
supply: 230 v ac
enclosure: field mounting, ip 65
output: 2 co relay contact, rating 5 amp resistive at 230 v ac