Listing ID #81234
Company Information
Ask for more detail from the seller
Contact SupplierWe offer Cylindrical Autoclave which is of high premium quality and can be availed through us only. Our horizontal cylindrical autoclave is incorporated with water level indicator, vacuum breaker, automatic pressure control switch and steam trap. We are also a well known cylindrical autoclave manufacturers in India. Construction The unit has outer chamber, inner Chamber, Boiler, Lid and Jacket - all made of 304 grade stainless Steel. For controlling sterilization cycle, a three way valve or a multiport valve - made of S.S. is provided. It is supplied complete with vacuum breaker, water level indicator, steam trap and automatic pressure control switch. The whole unit is mounted on a robust tubular stand. It is available in the following standard sizes. Operatable on 3 Phase, 440 Volts A.C. Supply. Mode of Heating Electrically heated by special flange type/immersion type heaters bearing ISI mark, to work on 440 volts three phase 50 cycles. Working Pressure The pressure inside the chamber is variable from 5 psi. to 20 psi. But the normal recommended pressure for sterilization process is 1.2 kgf/cm sq.g ( 15 psi - 17 psi ) Working Temperature : 121° C Hydrotest Pressure : 2.5 kgf/cm sq.g ( 35 psi )
Height | X | Dia | Volume (Ltrs.) | Load (KW) |
---|---|---|---|---|
400mm | X | 600mm | 78 | 6 |
500mm | X | 600mm | 135 | 10 |
550mm | X | 750mm | 152 | 9 |
400mm | X | 1100mm | 162 | 12 |
500mm | X | 1200mm | 185 | 12 |
600mm | X | 1200mm | 300 | 18 |
750mm | X | 1200mm | 525 | 18 |
Standard Controls
Multiple Operating Valve : To carry out all functions of sterilization cycle at one point i.e. steam to jacket, steam to chamber, fast/ slow exhaust and vacuum/ drying.
Door : Single door shall be fitted with radical shooting arm, provided with automatic pressure locking device so that the door can not be opened till chamber pressure is fully exhausted.
Quick Vacuum Drying Apparatus : This Allows the filtered and sterilized air to break the chamber vacuum & helps in quick-drying.
Accidental Vacuum Breaker : A safety device so jacket against accidential vacuum in it and to remove residual air from it.
Safety Valve : A safety device against excess pressure in jacket and steam generator.
Dial Type Thermometer : Indicates sterilization temperature.
Plug Screen : A device to prevent chamber, discharge line from lint / sediment.
Chamber Condensate Line : Incorparated with spirax thermosatic steam trap and check valve for perfect condensation from chamber to achieve optimum temparature.
Pressure & Compound Gauge : Indicates jacket and chamber pressure / vacuum resp.
Steam Generator (Boiler) : Shall be attached to underneath the jacket. It shall be fitted with -
|