Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    CT PT Analyzer

    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world

    Leveraging upon our superior quality examination facility, we are able to offer our clients the best in class CT PT Analyzers. We are referred as the significant entity involved in the supplying of....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 12 Years
    • building Nature of Business Retailer

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details

    Product Details no_img_icon

    Leveraging upon our superior quality examination facility, we are able to offer our clients the best in class CT PT Analyzers. We are referred as the significant entity involved in the supplying of the CT PT Analyzer in India. Innovative designing, trouble-free performance and long life span of these CT PT Analyzers have helped them bag a lot of appreciation. Place your order to fetch discounted deals.
    A compact 15kg unit with complete measurement function, it can test all types of current/potential transformer for :

    • Excitation curve and parameters test
    • Turns ratio test
    • Ratio and phase error test
    • Polarity mark check
    • Coil resistance measurement
    • Secondary loop burden measurement
    • Transient CT Parameters test
    • CT nameplate guess
    • Saturation hysteresis loop curve measurement

    Tests for voltage transformer:
    • Turns ratio test and phase angle error test
    • Polarity test
    • Secondary burden test
    • Coil resistance test

    Applications for CT/PT analyzer:
    • CT nameplate check
    • CT parameters check in work burden
    • CT transient parameters analysis
    • PT routine test

    Test standards : IFC 6CO44-1, IFC60044-6, GB 1208, GB16847, C57.13
    Turns ratio measurement :
    • Range: 1~350006
    • 1~2000 error<0.05%
    • 2000~5000 error <0.1%
    • 5000v35000 error<0.2%
    • Maximum knee voltage measurement :45kV


    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for CT PT Analyzer?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice