    Item Code: RXSOL-40-4028-025 Supplementary corrosion inhibitor - open or closed cooling systems is an innovative, supplementary corrosion inhibitor developed specifically for use in open or closed....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 9 Years
    • building Nature of Business Manufacturer
    • Year of Establishment 1996

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    Item Code: RXSOL-40-4028-025
    Supplementary corrosion inhibitor - open or closed cooling systems is an innovative, supplementary corrosion inhibitor developed specifically for use in open or closed cooling systems. In particular, RXSOL-40-4028 creates an insoluble polymeric surface complex on copper and its alloys, and also reacts with copper in solution.also works synergistically with other inhibitors to effectively control the corrosion of steel and aluminium in the system.
    1) Corrosion Inhibitor Nitrite based for CLOSED LOOP:
    RXSOL-40-4023 is a high performance nitrite based closed circuit inhibitor.
    Nitrite based Corrosion Inhibitor for Water and Glycol Brine system is a multimetal corrosion inhibitor based on nitrate and othe organic compounds with special yellow metal corrosion inhibitor and antiscaling chemical that helps to prevent scale deposition or also removes adhering loose scale deposits from the heat transfer fluid system.
    The disadvantages of not treating the closed circuit water can be equally troubling for the system operator:- 1. Leakage in PHE and AHU due to corrosion 2. Plugging and clogging of tubes and reduced flow rate 3. REduced heat transfer 4. Need of regular descalling that incurs shutdowns, loss of labor and time 5. Fouling of brine of chiller water
    Chemical tratment removes dissolved oxygen that cause oxidation of metal to metal oxide i.e., Iron Oxygen = Iron Oxide (Rust)
    The chemical also contains a specific inhibitor to protect copper from corrosion and removesprevents any sort of scale formation in the system. Part No.: RXSOL-40-4023-025 .
    2.Corrosion inhibitor Low nitrite molybdate for closed circuits :
    RXSOL-40-4019 is a blend of superior quality low nitritemolybdate based water treatment product developed specifically for closed circuit systems.RXSOL-40-4019 also contains isothiazoline. Part No.: RXSOL-40-4019-025 .


    Additional Information

    • Port of DispatchINDIA, Middle EAST
    • Packaging DetailsPacking 5, 10, 25 , 210 4) Corrosion Inhibitor Nitrite - Phosphonate for CLOSED LOOP :It is a high performance nitrite based closed circuit inhibitor with phosphonate with unique formulation with ferrous & Non ferrous corrosion inhibitors, antiscalants , dispersant and buffer solution of non carbonate. Usefull for use in high or low temperature closed cooling water systems for the prevention of corrosion and scale formation in internal combustion engines, compressors, chiller system and DG sets. Protects all metals including cast iron, mild steels and copper. Recommended ppm levels are easily controlled by standered RXSOL test kit Nitrite / Chloride. Part No.:RXSOL-40-4013-020. 5) scale corrosion inhibitor Open - closed cooling systems: RXSOL-40-RXSOL-40-4022 is a versatile molybdate-organophosphonate blend of scale and corrosion inhibitors for open recirculating cooling water systems. RXSOL-40-4022 is designed for systems with corrosive water (low hardness and/or low alkalinity). RXSOL-40-4022 will provide protection over a wide range of operating parameters. pH booster mecahanism raise pH to provide additional corrosion protection.is a versatile molybdate-organophosphonate blend of scale and corrosion inhibitors for open recirculating cooling water systems. RXSOL-40-4022 is designed for systems with corrosive water (low hardness and/or low alkalinity). RXSOL-40-4022 will provide protection over a wide range of operating parameters.Part No.: RXSOL-40-4022-210. 6) Corrosion Inhibitor Nitrite based for CLOSED LOOP ::Engine Jacket Cooling or heating system, Chiller Water Circuit, Glycol Brine System, Hot Water or steam Circuit, Engine Coolant,Process chilling and heating system etc. Part No.:RXSOL-40-4023-020.
    • Delivery Time1
    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for Corroision Inhibitor For Closed & Open Cooling System?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice