Contact SupplierProductTitle: CHLORIS LITE
Product Category :Solar Power Products
Product Sub Category :Solar Inverter
Combined with solar power controller and inverter hybrid function.
DSP Controlled Design is used.
Pure sine wave output with inbuilt isolation.
User friendly display gives status of the system.
Intelligent automatic bypass & charging ( On utility mode)
Surge, over voltage, lightening protection.
Overload ,Short circuit, Deep discharge protection
MNRE approval (Under Processing)
MODEL | 500W | 1000W | 2000W | 2500W | 3000W |
Rated power | 500 W | 1000 W | 2000 W | 2500 W | 3000W |
Battery voltage | 12 Vdc | 24/48 Vdc | 48 Vdc | ||
PV INPUT | |||||
Max. input voltage (Voc) | 60 Vdc | 100 Vdc | 150 Vdc | ||
Optimum operating voltage (Vmp) | 16 ~ 48 Vdc | 33 ~ 80 Vdc | 65 ~ 120 Vdc | ||
Max. charging current | 50 A | 50 A | 50 A | 65 A | 65 A |
Recommended PV configuration | 700 W | 1400 W | 2800 W | 3500 W | 3500 W |
AC INPUT | |||||
AC input range (bypass mode) | 0 ~ 132 Vac / 0 ~ 264 Vac (high-end limit) | ||||
Rated input voltage | 100 Vac / 110 Vac / 115 Vac / 120 Vac or 200 Vac / 220 Vac / 230 Vac / 240 Vac ± 25% | ||||
Rated Input frequency | 50 Hz / 60 Hz ± 5 Hz (auto-sense) | ||||
Max. charging current | 20 A | 30 A | |||
INVERTER OUTPUT | |||||
Output voltage | 100 Vac / 110 Vac / 115 Vac /120 Vac ± 2% or 200 Vac / 220 Vac / 230 Vac / 240 Vac ± 2% (settable) | ||||
Rated output power | 500 W | 1000 W | 2000 W | 2500 W | 3000 W |
Power factor | 1 | ||||
Rated output frequency | 50 Hz / 60 Hz ± 1% | ||||
Waveform | Sinusoidal | ||||
Max. efficiency (resistive load) | ≥ 78% | ≥ 82% | ≥ 85% | ≥ 85% | ≥ 85% |
Sleep mode | Settable (< 3% load) access in ≤ 2 min | ||||
Output voltage harmonic | ≤ 3% (linear load) | ||||
BATTERIES | |||||
Charging current | 5 ~ 50 A (settable) | 5 ~ 65 A (settable) | |||
DOD | 9.6 ~ 13.0 Vdc / cell (settable), 10.8 Vdc / cell (default) | ||||
EOD | 9.6 ~ 11.5 Vdc / cell (settable), 10.2 Vdc / cell (default) | ||||
Equalizing charge voltage | 13.6 ~ 15.0 Vdc / cell (settable), 14.1 Vdc / cell (default) | ||||
Floating charge voltage | 13.2 ~ 14.6 Vdc / cell (settable), 13.5 Vdc / cell (default) | ||||
Restroration point of overvoltage | 15.5 Vdc | 31.0 Vdc | 62.0 Vdc |