    0-50gm Aluminium Chemical Earthing Electrodes, Length : 0-250mm

    • MOQ100 Piece
    • MaterialAluminium
    • Length0-250mm
    • Weight0-50gm
    • Thickness0-3mm
    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 12 Years
    • building Nature of Business Retailer
    • gst icon GST No. 09AABCU4873H1Z0

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • Thickness0-3mm
    • Weight0-50gm
    • MaterialAluminium
    • ApplicationEarthing Purpose
    • Length0-250mm
    • TypeChemical Earthing Electrodes

    We are counted among the well known Manufacturers, Suppliers and Exporters of Chemical Earthing Electrodes. The Electrodes we make available dissipates lightning strikes and discharges. EPABX Systems/RF Antennae, Transformers HT/LT, Panels Distribution/Power factor, CNC m/c, Testing Equipment /System, Uninterrupted Power Supply, Generators, etc. are some of the components required for the proper functioning of our Earthing Electrodes. One can obtain these at market-leading rates from us.
    Statutory Requirements of
    Earthing/Grounding of System/equipment
    As per Indian Earthing Standard IS 3043:1987
    EPABX Systems/RF Antennae Etc

    • Provision should be there for at least one distinct separate dedicated body Earthing in order to provide safety aspects for shock to human life and charge dissipation of spurious voltage generated by the system because of surges.
    • Provision should be there for at least one distinct separate dedicated Neutral Earthing in order to provide localized Neutral to make Neutral strong and provide path to residual voltage of Neutral.
    • The Neutral-Earth voltage should be measured, and it should be low as 2 -3 volts or less as possible. In case of high Neutral-Earth a separate localized Earthing point should be connected to Neutral of the system


    Transformers HT/LT

    • In case Transformers HT/LT : Provision should be there for at least two distinct separate body Earthing in order to provide safety aspects for shock to human life.

     

    The Neutral should be Earthed with at least two distinct separate interconnected Earthing in order to achieve sufficient current dissipation and consistent/low neutral – earth voltage.
    Panels Distribution/Power factor

    • In case of  Panels for Distribution/Power factor : Provision should be there for at least two distinct separate bodies Earthing in order to provide safety aspects for shock to human life.


    CNC m/c

    • In case of medium and high rating CNC m/c : Provision should be there for at least two distinct separate body Earthing in order to provide safety aspects of electronic circuit and for shock to human life. It provides safety of electronic circuit against surges/spikes generated by the induction current.

     

    The Neutral should be Earthed with at least one distinct separate Earthing in order to achieve sufficient current dissipation and consistent/low
    Neutral – Earth voltage.
    Testing Equipment /System

    • Provision should be there for at least one distinct separate dedicated body Earthing in order to provide safety aspects for shock to human life and charge dissipation of spurious voltage generated by the system because of surges.
    • The Neutral-Earth voltage should be measured, and it should be low as 2 -3 volts or less as possible. In case of high Neutral-Earth a separate localized Earthing point should be connected to Neutral of the system.

     

    Uninterrupted Power Supply

    • Provision should be there for at least one distinct separate dedicated body Earthing in order to provide safety aspects for shock to human life and interruption of sinusoidal charge dissipation of spurious voltage generated by the system because of surges.
    • The Neutral-Earth voltage should be measured, and it should be low as 2 -3 volts or less as possible. In case of high Neutral-Earth a separate localized Earthing point should be connected to Neutral of the system.


    Generators

    • In case of medium and high rating generators : Provision should be there for at least two distinct separate body Earthing in order to provide safety aspects for shock to human life.

     

    The Neutral should be Earthed with at least two distinct separate interconnected Earthing in order to achieve sufficient current dissipation and consistent/low neutral – earth voltage

     

    • In case of Extra high rating generators:

    Number of Body/Neutral earthing points should be increased in order to cope up with high spurious voltage generated by the equipment.


    Download


    Download Detail File : Click Here
    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry
    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for Chemical Earthing Electrodes?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice