    • Regulation of the heating blockPID regulator
    • Power Supply230 V AC, 50 Hz.
    • Temperature RangeRoom temperature to 600 Deg C
    • Accuracy+/- 0.5 Deg C
    • Power consumption1000 Watts
    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 11 Years
    • building Nature of Business Retailer

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • Regulation of the heating blockPID regulator
    • Power Supply230 V AC, 50 Hz.
    • Temperature RangeRoom temperature to 600 Deg C
    • Accuracy+/- 0.5 Deg C
    • Power consumption1000 Watts

     

    Product Description
    The Test instrument Temperature Calibration Bath consist of two single enclosures. Front size 150 X 150 mm & 280 mm depth. They are connected with each other & equipped with a portable handle. The left enclosure contains a block with bore diameter of 18.5 mm & 110 mm depth which can reached from the top, face the reception of the test piece. In this block the heating cartridge & temperature sensor for the determination of the block temperature are installed / accesses from the bottom.

     

    The right enclosure contains:

    • PID controller for control of the block temperature in which we can see the set value & present temperature of the block.
    • Power switches & power on indicator
    • Fan ON / OFF switch for cooling the block.

    Operating Instructions:

    The test instrument  is a portable unit for service / calibrating / testing purpose as well as for operating & laboratory tasks.

    • After switching on the mains power switch the PID controller shows the temperature of the block. (PV). Below that green color LED shows the set value of the block (SV). To adjust the set point, press key (2) then a dot LED blinks near the first digit, then using up key (3) & down key (4) set the 0 – 9 digit again push the (2) key to move  the dot LED to the second digit using up & down key. After setting the set point value press the set (1) key for setting the temperatures. For auto tuning press (2) key for 2 seconds the ‘At’ from OFF to ON. Then press (1) key to active the auto tuning process, During auto tuning, the instrument executes on contr. After 2 cycles of ON – OFF action, the instrument will obtain the values of PID parameters. If you want to escape from auto tuning status, press& hold key (2) for about 2 seconds until ‘At’ parameters appear again. Change ‘At’ from ‘ON’ to ‘OFF’, press (1)  key to confirm, then the auto tuning process will be cancelled.
    • The PV shows continuously the temperature of the heating block. If the adjusted set temperature in the heating block is reached, the heating energy radiated from the block is dispensed by short switching on pulses of the heating cartridge, so the temperature inside the block is kept constant.
    • Cooling down the heating lock can be done quickly by switching ON the fan which produces higher amount of cooling air.

    Adapter Pockets:

    It has to be made sure that the heat transmission resistance between the heating block & the test piece (thermometer, temperature sensor, temperature switch) is as low as possible. Therefore it is necessary  to use exactly adapted pockets.

     

    Technical Specifications:


    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for Calibration Bath?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice