Company Information
Ask for more detail from the seller
Contact SupplierSl. No. | Test Prescribed in IS:2202 (Part-I), 1999 | Minimum Value for Conformity | Observed Value |
1 | Dimension & squareness test as per IS:4020 (Part-2), 1998 | Height & width shall be measured within an accuracy of 1.0 mm | Within specified limitt |
2 | General flatness test as per IS:4020 (Part-3), 1998 | Squareness shall be measured to an accuraty of 1.0 mm | Within specified limit |
3 | Local planeness test as per IS:4020 (Part-4), 1998 | Planeness will be measured to an accuracy of 0.1 mm | Within specified limit |
4 | Impact indentation test as per IS:4020 (Part-5), 1998 | Indentation will be measured to an accuracy of 0.1 mm | Within specified limit |
5 | Flexure test as per IS:4020 (Part-6), 1998 | The deflections will be measured to an accuracy of 0.1 mm | Within specified limit |
6 | Edge loading test as per IS:4020 (Part-7), 1998 | The deflections shall be measured to an accuraty of 0.1 mm | Within specified limit |
7 | Shock resistance test as per IS:4020 (Part-8), 1998 | 4 to 5 shock/min | Within specified limit |
8 | Buckling test as per IS:4020 (Part-9) 1998 | Deformation is measured to an accuracy of 1 mm, 5min. after application of the load and 15 min after unloading | Within specified limit |
9 | Slamming test as per IS:4020 (Part-10) 1998 | 50 times on the nail at the rate of 4-5 drops/min | Found O.K. |
10 | Misuse test as per IS:4020 (Part-11) 1998 | It should pass after applying 200 N force to the handle at right angle to the plane of the frame. | Satisfacory |
11 | Varying humidity test as per IS:4020 (Part-12), 1998 | Deviation shall be measured to an accuraty of 1.0 mm | Within specified limit |
12 | End immersion test as per IS:4020 (Part-13), 1998 | These shall be no de-lamination | No de-lamination found |
13 | Knife test as per IS:4020 (Part-14), 1998 | Minimum pass standard | Excellent |
14 | Glue adhesion test as per IS:4020 (Part-15) 1998 | There shall be no de-lamination | No de-lamination found |
15 | Screw withdraw test as per: IS 4020 (Part-16), 1998 | Applied load shall be 2.0 mm per min for complete withdrawal of the screw withing specified limit | Within specified limit |