Contact SupplierSl. No. | Test Prescribed in IS:1659 - 1990 | Minimum Value for Conformity | Observed Value |
1 | Dimensional changes caused by humidity | There shall be no de-lamination in the extreme range of humidity Dimensional change shall not be more than + 1 mm in local planeness | No de-lamination observed. Dimensional change within the specified limit |
2 | Water Resistance | There shall not be any de-lamination after 72 hours boiling. | No de-lamination observed. |
3 | Adhesion of Piles | Minimum pass standard | Excellent |
4 | Modulus of Test | No appreciable sign of separation edge. | Satisfactory |
5 | Modulus of Rupture | 50 N/sq.mm | 67 sq.mm |
6 | Modulus of Elasticity | 5000 N/sq.mm | 6025 N/sq.mm |