Key points of Flush-Door
Flush Doors are dimensionally stable, durable, totally resistant to termites and borers and are 100% boiling water proof.
Hardwood core veneers of full width, dimensions and thickness.Completely made from perfectly seasoned and chemically treated prime quality Hardwood timber.
Manufactured under strict quality control thereby meeting high level of perfection in specified tests like glue adhesion, knife, flexure, edge loading, impact resistance, screw withdrawal holding.
Hot pressed with extra thick 'A' Quality face veneers.
Our well-maintained and capacious warehouse helps us in managing systematically arrangement of goods and meeting massive requirements of the clients at a time. We have hired experienced quality auditors who stringently check the raw materials against varied quality parameters before procurement. Thus, we ensure quality products at buyer's end. We present attractive Plywood Flush Doors with innovative designs. Our Plywood Flush Doors add to the decor of any commercial place or residential place. These Plywood Flush Doors come in different dimensions as per the requirements and specifications provided by clients.
Usage
Flush doors are used for bed room, drawing room, bath room etc.
Value for money
High resistance to borer and termite
Weather resistant
High Density strong doors
Size
Thickness- 30mm, 32mm and 35mm
Technical Specifications
Prescribed Test
Values for Conformity
Observed Value
End Emmersion Test
No delamination
No delamination
Glue Adhesion test
No delamination
No delamination
Knife test
Minimum pass standard
Pass
Impact Indentation
No cracking, tearing or
delamination.
Depth of indentation
0.13mm
<0.2mm
Slamming
No visible damage
after 50 drops
No damage
Buckling (deflection in mm)
After 5 mts of 40 Kg
loading 15 mts
after load removal
No deterioration
Initial deflection not greater
than 50mm.
Residual deformation after
15 minutes of unloading
not greater than 5mm.
No deterioration
34mm
2.91mm
3.16
Edge loading
(deflection in mm)
After 15 mts of 100 Kg
loading 3 mts after load
removal
Lateral buckling
Deflection at max load not
greater than 5mm.
Residual deflection
after removal of load not
greater than 0.5mm
Not more than 2mm.
during loading
No residual
buckling after load removal
4.2mm
0.48mm
No lateral buckling
No residual buckling
Screw withdrawal strength
No damage
Not less than 10004
Surface condition: No visible
damage by determination or
extra chhiping off
1800N
No visible damage