    • Country of OriginIndia
    • Brand NameVSI
    • Voltage220/240V AC, 50/60 Hz, 800 VA
    • Grating1800 Lines grating (USA)
    • SoftwareUser friendly software
    • Range185-930 nm.
    • FeaturesHighly Stable, Accurate & True Double Beam Optics
    • Variable Bandwidth0.1 to 2 nm.

    VSI Electronics Private Limited is an established manufacturer, supplier and exporter of Atomic Absorption Spectrophotometer Double Beam from India. The Atomic Absorption Spectrophotometer Double Beam offered by the company are high on quality, performance and are made of the finest quality raw materials, making them durable and long lasting.

    Atomic Absorption Spectrophotometer (Double Beam), Ebert type monochromator with 1800 lines/mm halographic grating, 0 to 2nm SBW, 190-900nm Wavelength range. Eight hollow cathode lamp turret assembly with moduled eight independent power supplies. Built-in background corrector in the system using high intensity and high speed Deuterium lamp. Automatic calibration using up to maximum 10 standards and recalibration with a single standard. Direct concentration readout using different modes (K-Factor Liner regression and Quadratic regression). Display of the signal energy in the form of BAR signal and numeric form. ABS., %TRANS & CONC. Display facility. Absorbance range from 0 to 3.0 ABS. Titanium Burner of 100mm Air-acetylene and 50mm N2O – Acetylene Flames. Corrosion resistant nebulizer with Platinum – iridium capillary, Impact bead, Supplied with computer interface software.

     

    SALIENT FEATURES

    • Highly Stable and Accurate
    • True Double Beam Optics
    • 8 Lamp Turret
    • Range 185-930 nm.
    • 1800 Lines grating (USA)
    • Variable Bandwidth 0.1 to 2 nm.
    • User Friendly Software
    • Automatic calibration using up to maximum 10 standards and recalibration with a single standard.
    • Direct concentration readout using different modes (K-Factor Liner regression and Quadratic regression)

     

    We also offer Single Beam Atomic Absorption Spectrophotometer (VSI-2100).

    Note: Appearance & Specifications are subject to change due to continuous development.


    Technical Specifications Of Atomic Absorption Spectrophotometer Double Beam (VSI-2102)

    ParameterComputer Controlled, High Performance, Optically Double Beam Atomic Absorption Spectrophotometer Having Following Specifications:
    Optics MonochromatorReal time Double Beam with Deuterium background CZ design with 330mm focal length, 1800 lines/mm grating and 185-930nm wavelength range, Automatic emission wavelength selection and peaking. Continuously variable slits with 0.2 to 2 nm spectral bandwidth. Automatic wavelength scanning. Selected wide range
    DetectorHigh performance multi-alkali Photo multiplier tube R928
    Motorized Lamp TurretEight Lamp motorized turret with automatic lamp selection and individual lamp peaking automatically warmed up. Compatible with standard & coded hollow cathode lamps
    Background CorrectionDeuterium arc Radiation ULTRA FAST-PULSE 1024 Hz background corrector wavelength correction range 185-425 nm., Corrects to 2.5 total absorbance
    Automatic Flame Control UnitProgrammable gas controller with digital display of flow, full safety interlock including built in pressure regulator on both lines, power failure protection, auto shut down of flame, burner drain, door interlock and electronic flame igniter and real time status sensing, fitted bung and pressure relief bung
    NebulizerFully inert nebulizer
    Spray ChamberPTFE spray chamber and adjustable impact bead aerosol
    BurnerTitanium burners for C2H2 – N2O & C2H2 – AIR
    SensitivityGreater than 0.7 Abs for 5 mg/L Copper Solution with an RSD of less than 0.5% Characteristics concentration of copper 0.030 µg/ml.
    Output PortUSB, Wi-Fi, BLUETOOTH CONNECTIVITY FOR PC/INTERNET
    SoftwareWindows 10 based user friendly software
    Dimension100x55x58 cm. (LxHxB)
    Weight65 Kg Unpacked
    Electrical Requirement220/240V AC, 50/60 Hz, 800 VA
    Hollow Cathode Lamps67 Element High Intensity Single Element available
    Standard AccessoriesSoftware CD, USB Cable, Manual, 4 Cathode Lamps, Acetylene Cylinder (Optional), Regulators (Optional), Moisture Filter (Optional)
    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry

    Product Images

    • Atomic Absorption Spectrophotometer Double Beam
    • Atomic Absorption Spectrophotometer Double Beam
    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for Atomic Absorption Spectrophotometer Double Beam?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice