Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Lasany Atomic Absorption Spectrophotometer

Listing ID #6922181

  • MOQ 1 Piece
  • Wavelength Range190-900
  • Wavelength Accuracy±0.2
  • Brand NameLasany
  • Instrument TypeSingle Beam Reflection Achromatic Optics System
  • Supply Type Exporter, Supplier
  • Preferred Buyer Location All over the world
View More Details
Send Enquiry

Company Information

Somwar Peth, Pune, Maharashtra
08048778268
  • Member Since 8 Years
  • Nature of Business Trader
  • GST No. 27AABFJ1118P1ZA

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Wavelength Range 190-900
  • Wavelength Accuracy ±0.2
  • Brand Name Lasany
  • Instrument Type Single Beam Reflection Achromatic Optics System
  • Monochromator Aberration Corrected Czerny-Turner
  • Model LI-5310

SALIENT FEATURES

  • Advance technology for intelligent stray light measure and correction
  • Original Optical Noise Reduction & Automatic measurement and stray light dynamic detected without any reference materials and incremental cost. It improves instrument’s optical performance, optical  precision, linear range and background correction effectively
  • Develop internal lamp control technology. It makes normal hallow cathode lamps self-absorption background correction possible without and influence to instrument's stability. Meanwhile it will prolong working life of the lamps. Normal hallow cathode lamps are highly economical than special lamps
  • Original ''Hg lamp-regent'' gradient measurement. we established an exact mathematical model to estimate “single beam linear and balance "specification. This technology provided a fast and
  • economic method for instrument self testing system. It also established a brand new method to improve instrument's detection Performance.
  • Numerous technological innovation and renewal such as design aesthetics, element lamp multi dimensional automatic adjustment system, gas path electronics functional and modular design, No-adjustment D-lamp holder and so on.

 

OPTIONS:

  • Graphite Furnace
  • Auto-Sampler for Graphite Furnace
  • Hydride Generator
  • Wide range of Hollow-Cathode Lamps(Single/Multi Element)


Specifications

Optical System Instrument Type Single Beam Reflection Achromatic Optics System
Monochromator Aberration Corrected Czerny-Turner
Dispersion elements Grating system 1200 line/mm characterization area 40mm2
Scintillation wavelength 250nm
Bandwidth 0.1,0.2,0.4,1nm(4 step auto switching)
WL Range 190-900
WL Accuracy ±0.2
WL Repeatability ±0.1 nm max
Resolution Min 3 lines (279.5 & 279.8 peak and Valley )
HCL housing Standard 4 lamp turret .
( 1 for measurement , 3 in warm-up mode ) Option :- 6 Lamp / 8 Lamp Turret .
Gas control Automatic control & optimization (flow/pressure)
Safety measures Gas Leak check, prevention of gas release when flame dies out,
prevention of flashback through pressure monitoring.
Photometric properties Measurement Aberration-corrected Czerny-Turner mounting
Photometric Range 0-125%, -0.1-3.00A
Static Baseline Drift (Cu) +-0.003A/30min
Dynamic Baseline Drift (Cu) +-0.006A/30min
Background Correction High speed self-reversal (BGC-SR) method: High
speed D2 lamp method (BGC-D2)
Atomization System    
Flame Characteristic Concentration (Cu) 0.025 μg/ml max
Detection limit (Cu) 0.004 μg/ml max
Precision RDS =0.5%
Burner Air cooled Titanium
Nebulizer High-efficient Nebulizer
Spray chamber Anticorrosion material
Safety measures Flame fuel gas, power assisted gas abnormal pressure protection
Data Process Test Manner Flame , flame emission .
Concentration standard curve, standard addition, interpolation
Times of repetitive Measurement 1-30 times, Average Value of A&C
Report Print parameters, date result
Other Dimension & Weight
(Flame)
700×420×550 mm; 103 kg(approx.)
Power (Main unit with(Flame) AC 220 V ±10%, 50 Hz without sharp fluctuations.
Working Temperature range 10~300C
Working Humidity range 40%~85%





Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry

Company Details close-icon

We are supplying the scientific and pahram equipment since 1989 in pune and surroung region of pune ,ahamadnagar, aurangabad, hydrabad and we also exported to usa and oman
we are supplying the various range of scieitic instrument and pharam equipment laboratory glassware plasticware
labortory chemicals .we supply to variosu industries following item
oven
incuberator
autoclave
laminar flow
bod incureator
stirrer
magnetic stirrer
centriuge
balance
microscope.
Pharma equipment
Tablet dissolution tester
Friability apparatus
Disintegration machine
Leak test apparatus
Peristaltic pump
Microscope
Analytical balance
Precision balance
Table top balance
Hot air oven
BOD INCUBATOR
MEMMERT TYPE OVEN
TRAY DRYER
HOT PLATE
WATER BATH
SEROLOGICAL WATER BATH
WATERBATH WITH 6 AND 12 HOLE
CONSTANT TEMPERATURE WATERBATH
INCUBATOR
HEATIMG MENTAL
RECTANGULAR WATER BATH
VACCUM OVEN
MUFFWL FURNACE
PH METER
CONDUCTIVITY METER
DO METER
SPECTROPHOTOMETER
UV SPECTROMETER
IR BALANCE
REFRECTOMETER
POLARIMETER
ABLE FLASH POINT
VISCOSITY BATH
  • Nature of Business Manufacturer / Exporter / Service Provider / Supplier / Retailer / Trader
  • Number of Employees Below 20
  • Year of Establishment 1989
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Atomic Absorption Spectrophotometer?

Quantity
Seller Contact Details

Find similar products

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Lasany Atomic Absorption Spectrophotometer at Best Price in Pune - ID: 6922181
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Lasany Atomic Absorption Spectrophotometer

Listing ID #6922181

  • MOQ 1 Piece
  • Wavelength Range190-900
  • Wavelength Accuracy±0.2
  • Brand NameLasany
  • MonochromatorAberration Corrected Czerny-Turner
  • Supply Type Exporter, Supplier
  • Preferred Buyer Location All over the world
View More Details
Send Enquiry

Company Information

Somwar Peth, Pune, Maharashtra
08048778268
  • Member Since 8 Years
  • Nature of Business Trader
  • GST No. 27AABFJ1118P1ZA

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Wavelength Range 190-900
  • Wavelength Accuracy ±0.2
  • Brand Name Lasany
  • Monochromator Aberration Corrected Czerny-Turner
  • Model LI-5310
  • Instrument Type Single Beam Reflection Achromatic Optics System

SALIENT FEATURES

  • Advance technology for intelligent stray light measure and correction
  • Original Optical Noise Reduction & Automatic measurement and stray light dynamic detected without any reference materials and incremental cost. It improves instrument’s optical performance, optical  precision, linear range and background correction effectively
  • Develop internal lamp control technology. It makes normal hallow cathode lamps self-absorption background correction possible without and influence to instrument's stability. Meanwhile it will prolong working life of the lamps. Normal hallow cathode lamps are highly economical than special lamps
  • Original ''Hg lamp-regent'' gradient measurement. we established an exact mathematical model to estimate “single beam linear and balance "specification. This technology provided a fast and
  • economic method for instrument self testing system. It also established a brand new method to improve instrument's detection Performance.
  • Numerous technological innovation and renewal such as design aesthetics, element lamp multi dimensional automatic adjustment system, gas path electronics functional and modular design, No-adjustment D-lamp holder and so on.

 

OPTIONS:

  • Graphite Furnace
  • Auto-Sampler for Graphite Furnace
  • Hydride Generator
  • Wide range of Hollow-Cathode Lamps(Single/Multi Element)


Specifications

Optical System Instrument Type Single Beam Reflection Achromatic Optics System
Monochromator Aberration Corrected Czerny-Turner
Dispersion elements Grating system 1200 line/mm characterization area 40mm2
Scintillation wavelength 250nm
Bandwidth 0.1,0.2,0.4,1nm(4 step auto switching)
WL Range 190-900
WL Accuracy ±0.2
WL Repeatability ±0.1 nm max
Resolution Min 3 lines (279.5 & 279.8 peak and Valley )
HCL housing Standard 4 lamp turret .
( 1 for measurement , 3 in warm-up mode ) Option :- 6 Lamp / 8 Lamp Turret .
Gas control Automatic control & optimization (flow/pressure)
Safety measures Gas Leak check, prevention of gas release when flame dies out,
prevention of flashback through pressure monitoring.
Photometric properties Measurement Aberration-corrected Czerny-Turner mounting
Photometric Range 0-125%, -0.1-3.00A
Static Baseline Drift (Cu) +-0.003A/30min
Dynamic Baseline Drift (Cu) +-0.006A/30min
Background Correction High speed self-reversal (BGC-SR) method: High
speed D2 lamp method (BGC-D2)
Atomization System    
Flame Characteristic Concentration (Cu) 0.025 μg/ml max
Detection limit (Cu) 0.004 μg/ml max
Precision RDS =0.5%
Burner Air cooled Titanium
Nebulizer High-efficient Nebulizer
Spray chamber Anticorrosion material
Safety measures Flame fuel gas, power assisted gas abnormal pressure protection
Data Process Test Manner Flame , flame emission .
Concentration standard curve, standard addition, interpolation
Times of repetitive Measurement 1-30 times, Average Value of A&C
Report Print parameters, date result
Other Dimension & Weight
(Flame)
700×420×550 mm; 103 kg(approx.)
Power (Main unit with(Flame) AC 220 V ±10%, 50 Hz without sharp fluctuations.
Working Temperature range 10~300C
Working Humidity range 40%~85%





Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry

Company Details close-icon

We are supplying the scientific and pahram equipment since 1989 in pune and surroung region of pune ,ahamadnagar, aurangabad, hydrabad and we also exported to usa and oman
we are supplying the various range of scieitic instrument and pharam equipment laboratory glassware plasticware
labortory chemicals .we supply to variosu industries following item
oven
incuberator
autoclave
laminar flow
bod incureator
stirrer
magnetic stirrer
centriuge
balance
microscope.
Pharma equipment
Tablet dissolution tester
Friability apparatus
Disintegration machine
Leak test apparatus
Peristaltic pump
Microscope
Analytical balance
Precision balance
Table top balance
Hot air oven
BOD INCUBATOR
MEMMERT TYPE OVEN
TRAY DRYER
HOT PLATE
WATER BATH
SEROLOGICAL WATER BATH
WATERBATH WITH 6 AND 12 HOLE
CONSTANT TEMPERATURE WATERBATH
INCUBATOR
HEATIMG MENTAL
RECTANGULAR WATER BATH
VACCUM OVEN
MUFFWL FURNACE
PH METER
CONDUCTIVITY METER
DO METER
SPECTROPHOTOMETER
UV SPECTROMETER
IR BALANCE
REFRECTOMETER
POLARIMETER
ABLE FLASH POINT
VISCOSITY BATH
  • Nature of Business Manufacturer / Exporter / Service Provider / Supplier / Retailer / Trader
  • Number of Employees Below 20
  • Year of Establishment 1989
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

Looking for Atomic Absorption Spectrophotometer?

Quantity
Seller Contact Details

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice