Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Aqueous Ammonia (Liquor Ammonia)

Listing ID #3797255

  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world

Ammonia in Water, commonly known as Aqua Ammonia renders it safe to handle and helps avoid the hazards that accompany use of Ammonia Gas by greatly reducing its vapour pressure. Also known as....
View More Details
Send Enquiry

Company Information

  • Member Since 14 Years
  • Nature of Business Retailer
  • Year of Establishment 1982

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Ammonia in Water, commonly known as Aqua Ammonia renders it safe to handle and helps avoid the hazards that accompany use of Ammonia Gas by greatly reducing its vapour pressure. Also known as Ammoniacal Liquor, it is an inorganic chemical used as a liquid chemical in various industries like Rubber, Pharmaceuticals among others. Sometimes called Ammonium Hydroxide, the chemical formula is NH4OH with UN No. 2672 and CAS registry is 1336-21-6.

Commonly manufactured with a concentration of about 25% w/w, Ammonia Solution is supplied in varying Packaging capacities ranging from 5 Lt. To 235 Lt. HMHDPE Plastic containers, 6 MT to 15 MT Tankers and 22 MT ISO Tankers.

 

AQUEOUS AMMONIA (LIQUID AMMONIA) - SPECIFICATIONS

 

Description A Clear Colorless Liquid Odor Strongly Pungent & Characteristic
Solubility Mixable with water in all Proportions
Identifications I.P.Identification test for ammonia positive
Residue On Evaporation 0.0068 %
Specific Gravity @ 25 c 0.905 gms
Chloride (AS CL) Less than 0.0005 %
Sulphate (AS SO4) Less than 0.0002 %
Iron (AS Fe) Less than 0.00002 %
Carbonate (AS CO3) Less than 0.002 %
Assay Contents of Ammonia i.e NH3 = 25 % @ 27 C Contents of Water 75 %
Liquor Ammonia conforms to IS : 799 - 1985
 
AQUEOUS AMMONIA (LIQUID AMMONIA) - SAFETY DATA

First Aid For Ammonia Solution (NH4OH)

Emergency Overview

POISON! DANGER! CORROSIVE. MAY BE FATAL IF SWALLOWED OR INHALED. MIST AND VAPOR CAUSE BURNS TO EVERY AREA OF CONTACT.

SAF-T-DATA(tm) Ratings (Provided here for your convenience)

  • Health Rating: 3 - Severe (Poison)
  • Flammability Rating: 0 - None
  • Reactivity Rating: 1 - Slight
  • Contact Rating: 4 - Extreme (Corrosive)
  • Lab Protective Equip: GOGGLES & SHIELD; LAB COAT & APRON; VENT HOOD; PROPER GLOVES
  • Storage Color Code: White Stripe (Store Separately)
 
Potential Health Effects

Inhalation

Vapors and mists cause irritation to the respiratory tract. Higher concentrations can cause burns, pulmonary edema and death. Brief exposure to 5000 ppm can be fatal.

Ingestion

Toxic! May cause corrosion to the esophagus and stomach with perforation and peritonitis. Symptoms may include pain in the mouth, chest, and abdomen, with coughing, vomiting and collapse. Ingestion of as little as 3-4 mL may be fatal.

Skin Contact

Causes irritation and burns to the skin

Eye Contact

Vapors cause irritation. Splashes cause severe pain, eye damage, and permanent blindness

Chronic Exposure

Repeated exposure may cause damage to the tissues of the mucous membranes, upper respiratory tract, eyes and skin.

Aggravation of Pre-existing Conditions

Persons with pre-existing eye disorders or impaired respiratory function may be more susceptible to the effects of this material.

 
First Aid Measures

Inhalation

Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Call a physician immediately.

Ingestion

If swallowed, DO NOT INDUCE VOMITING. Give large quantities of water. Never give anything by mouth to an unconscious person. Get medical attention immediately.

Skin Contact

Immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Call a physician, immediately. Wash clothing before reuse.

Eye Contact

Immediately flush eyes with gentle but large stream of water for at least 15 minutes, lifting lower and upper eyelids occasionally. Call a physician immediately. Immediate action is critical to minimize possibility of blindness.

 
First Aid Measures

Inhalation

Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Call a physician immediately.

Ingestion

If swallowed, DO NOT INDUCE VOMITING. Give large quantities of water. Never give anything by mouth to an unconscious person. Get medical attention immediately.

Skin Contact

Immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Call a physician, immediately. Wash clothing before reuse.

Eye Contact

Immediately flush eyes with gentle but large stream of water for at least 15 minutes, lifting lower and upper eyelids occasionally. Call a physician immediately. Immediate action is critical to minimize possibility of blindness.

 
Fire Fighting Measures

Fire

Autoignition temperature: 651C (1204F) Flammable limits in air % by volume: lel: 16; uel: 25

Explosion

Flammable vapors may accumulate in confined spaces

Fire Extinguishing Media

Use any means suitable for extinguishing surrounding fire. Use water spray to blanket fire, cool fire exposed containers, and to flush non-ignited spills or vapors away from fire

Special Information

In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full facepiece operated in the pressure demand or other positive pressure mode.

 
Accidental Release Measures

Ventilate area of leak or spill. Keep unnecessary and unprotected people away from area of spill. Wear appropriate personal protective equipment as specified in Section 8. Contain and recover liquid when possible. Do not flush caustic residues to the sewer. Residues from spills can be diluted with water, neutralized with dilute acid such as acetic, hydrochloric or sulfuric. Absorb neutralized caustic residue on clay, vermiculite or other inert substance and package in a suitable container for disposal.

US Regulations (CERCLA) require reporting spills and releases to soil, water and air in excess of reportable quantities. The toll free number for the US Coast Guard National Response Center is (800) 424-8802.

 
Handling and Storage

Keep in a tightly closed container, stored in a cool, dry, ventilated area. Protect against physical damage. Separate from incompatibilities. Store below 25C. Protect from direct sunlight. Containers of this material may be hazardous when empty since they retain product residues (vapors, liquid); observe all warnings and precautions listed for the product.

 
Exposure Controls/Personal Protection

Airborne Exposure Limits:

  • OSHA Permissible Exposure Limit (PEL): 50 ppm (NH3)
  • ACGIH Threshold Limit Value (TLV): 25 ppm (NH3) (TWA) 35 ppm (STEL)

Ventilation System

A system of local and/or general exhaust is recommended to keep employee exposures below the Airborne Exposure Limits. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area. Please refer to the ACGIH document, Industrial Ventilation, A Manual of Recommended Practices, most recent edition, for details.

Personal Respirators (NIOSH Approved)

If the exposure limit is exceeded and engineering controls are not feasible, a full facepiece respirator with an ammonia/methylamine cartridge may be worn up to 50 times the exposure limit or the maximum use concentration specified by the appropriate regulatory agency or respirator supplier, whichever is lowest. For emergencies or instances where the exposure levels are not known, use a full-facepiece positive-pressure, air-supplied respirator. WARNING: Air purifying respirators do not protect workers in oxygen-deficient atmospheres.

Skin Protection

Wear impervious protective clothing, including boots, gloves, lab coat, apron or coveralls, as appropriate, to prevent skin contact. Neoprene and nitrile rubber are recommended materials. Polyvinyl alcohol is not recommended.

Eye Protection

Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.

 

 

 

 


Company Details close-icon

Mysore Ammonia, with its origins from Mumbai, started as a family enterprise in 1962. Transforming over the years into a professional organization, it is today in the forefront of Ammonia Business in India and the Indian-Ocean Region with a presence in many other countries.
Mysore Ammonia was the first in India to start a Cylinder Filling Plant for Ammonia in 1979 and in 1984 was the first to start a Liquor Ammonia Manufacturing Plant in India. With a Long-Term outlook focused on Service, Quality and Safety, in the Ammonia Industry, Mysore Ammonia is known for Transparency in their interactions and good HR practices.
Respected for their business values, the Ethos of Mysore Ammonia is focused on Quality and Safety while their large volumes drive down costs. As a result of this potent combination Mysore Ammonia safely deliver a Quality Product at a Competitive Price providing Quality Service to their customers while persistently striving for continuous improvement of these services. They have implemented quality management systems in every function to achieve efficiency and effectiveness.
Only Indian Company sourcing Ammonia from the overseas besides India, and also the only Indian company with Manufacturing Plants and tie-ups for Production of Ammonia overseas, Mysore Ammonia is highly reputed in the industry for their Supply-Chain Management also. They follow their commitment to provide solutions as per customer needs and deliver where the Customers needs the Product; when they need it; and with consistent Quality & Quantity standards.
Customers normally have very low storage capacities though Ammonia is an essential chemical with various uses. Mysore Ammonia with their own Cylinders, Tanks, Trailers and Vehicles, combined with their Supply-Chain Management Systems, are the most reliable suppliers in every location they are presently supplying.
MYSORE AMMONIA has extensive expertise in regulatory matters pertaining to Anhydrous Ammonia and Ammonia Solution. They assist customers in Installation & Commissioning of their Storage tanks, equipment arrangement, Safety Training and in preparation of necessary regulatory documents as well as guide them in their compliance.
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
  • Number of Employees 50 - 100
  • Year of Establishment 1982
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for Aqueous Ammonia (Liquor Ammonia)?

Quantity
Seller Contact Details
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
Aqueous Ammonia (Liquor Ammonia) at Best Price in Mumbai - ID: 3797255
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Aqueous Ammonia (Liquor Ammonia)

Listing ID #3797255

  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world

Ammonia in Water, commonly known as Aqua Ammonia renders it safe to handle and helps avoid the hazards that accompany use of Ammonia Gas by greatly reducing its vapour pressure. Also known as....
View More Details
Send Enquiry

Company Information

  • Member Since 14 Years
  • Nature of Business Retailer
  • Year of Establishment 1982

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

Ammonia in Water, commonly known as Aqua Ammonia renders it safe to handle and helps avoid the hazards that accompany use of Ammonia Gas by greatly reducing its vapour pressure. Also known as Ammoniacal Liquor, it is an inorganic chemical used as a liquid chemical in various industries like Rubber, Pharmaceuticals among others. Sometimes called Ammonium Hydroxide, the chemical formula is NH4OH with UN No. 2672 and CAS registry is 1336-21-6.

Commonly manufactured with a concentration of about 25% w/w, Ammonia Solution is supplied in varying Packaging capacities ranging from 5 Lt. To 235 Lt. HMHDPE Plastic containers, 6 MT to 15 MT Tankers and 22 MT ISO Tankers.

 

AQUEOUS AMMONIA (LIQUID AMMONIA) - SPECIFICATIONS

 

Description A Clear Colorless Liquid Odor Strongly Pungent & Characteristic
Solubility Mixable with water in all Proportions
Identifications I.P.Identification test for ammonia positive
Residue On Evaporation 0.0068 %
Specific Gravity @ 25 c 0.905 gms
Chloride (AS CL) Less than 0.0005 %
Sulphate (AS SO4) Less than 0.0002 %
Iron (AS Fe) Less than 0.00002 %
Carbonate (AS CO3) Less than 0.002 %
Assay Contents of Ammonia i.e NH3 = 25 % @ 27 C Contents of Water 75 %
Liquor Ammonia conforms to IS : 799 - 1985
 
AQUEOUS AMMONIA (LIQUID AMMONIA) - SAFETY DATA

First Aid For Ammonia Solution (NH4OH)

Emergency Overview

POISON! DANGER! CORROSIVE. MAY BE FATAL IF SWALLOWED OR INHALED. MIST AND VAPOR CAUSE BURNS TO EVERY AREA OF CONTACT.

SAF-T-DATA(tm) Ratings (Provided here for your convenience)

  • Health Rating: 3 - Severe (Poison)
  • Flammability Rating: 0 - None
  • Reactivity Rating: 1 - Slight
  • Contact Rating: 4 - Extreme (Corrosive)
  • Lab Protective Equip: GOGGLES & SHIELD; LAB COAT & APRON; VENT HOOD; PROPER GLOVES
  • Storage Color Code: White Stripe (Store Separately)
 
Potential Health Effects

Inhalation

Vapors and mists cause irritation to the respiratory tract. Higher concentrations can cause burns, pulmonary edema and death. Brief exposure to 5000 ppm can be fatal.

Ingestion

Toxic! May cause corrosion to the esophagus and stomach with perforation and peritonitis. Symptoms may include pain in the mouth, chest, and abdomen, with coughing, vomiting and collapse. Ingestion of as little as 3-4 mL may be fatal.

Skin Contact

Causes irritation and burns to the skin

Eye Contact

Vapors cause irritation. Splashes cause severe pain, eye damage, and permanent blindness

Chronic Exposure

Repeated exposure may cause damage to the tissues of the mucous membranes, upper respiratory tract, eyes and skin.

Aggravation of Pre-existing Conditions

Persons with pre-existing eye disorders or impaired respiratory function may be more susceptible to the effects of this material.

 
First Aid Measures

Inhalation

Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Call a physician immediately.

Ingestion

If swallowed, DO NOT INDUCE VOMITING. Give large quantities of water. Never give anything by mouth to an unconscious person. Get medical attention immediately.

Skin Contact

Immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Call a physician, immediately. Wash clothing before reuse.

Eye Contact

Immediately flush eyes with gentle but large stream of water for at least 15 minutes, lifting lower and upper eyelids occasionally. Call a physician immediately. Immediate action is critical to minimize possibility of blindness.

 
First Aid Measures

Inhalation

Remove to fresh air. If not breathing, give artificial respiration. If breathing is difficult, give oxygen. Call a physician immediately.

Ingestion

If swallowed, DO NOT INDUCE VOMITING. Give large quantities of water. Never give anything by mouth to an unconscious person. Get medical attention immediately.

Skin Contact

Immediately flush skin with plenty of water for at least 15 minutes while removing contaminated clothing and shoes. Call a physician, immediately. Wash clothing before reuse.

Eye Contact

Immediately flush eyes with gentle but large stream of water for at least 15 minutes, lifting lower and upper eyelids occasionally. Call a physician immediately. Immediate action is critical to minimize possibility of blindness.

 
Fire Fighting Measures

Fire

Autoignition temperature: 651C (1204F) Flammable limits in air % by volume: lel: 16; uel: 25

Explosion

Flammable vapors may accumulate in confined spaces

Fire Extinguishing Media

Use any means suitable for extinguishing surrounding fire. Use water spray to blanket fire, cool fire exposed containers, and to flush non-ignited spills or vapors away from fire

Special Information

In the event of a fire, wear full protective clothing and NIOSH-approved self-contained breathing apparatus with full facepiece operated in the pressure demand or other positive pressure mode.

 
Accidental Release Measures

Ventilate area of leak or spill. Keep unnecessary and unprotected people away from area of spill. Wear appropriate personal protective equipment as specified in Section 8. Contain and recover liquid when possible. Do not flush caustic residues to the sewer. Residues from spills can be diluted with water, neutralized with dilute acid such as acetic, hydrochloric or sulfuric. Absorb neutralized caustic residue on clay, vermiculite or other inert substance and package in a suitable container for disposal.

US Regulations (CERCLA) require reporting spills and releases to soil, water and air in excess of reportable quantities. The toll free number for the US Coast Guard National Response Center is (800) 424-8802.

 
Handling and Storage

Keep in a tightly closed container, stored in a cool, dry, ventilated area. Protect against physical damage. Separate from incompatibilities. Store below 25C. Protect from direct sunlight. Containers of this material may be hazardous when empty since they retain product residues (vapors, liquid); observe all warnings and precautions listed for the product.

 
Exposure Controls/Personal Protection

Airborne Exposure Limits:

  • OSHA Permissible Exposure Limit (PEL): 50 ppm (NH3)
  • ACGIH Threshold Limit Value (TLV): 25 ppm (NH3) (TWA) 35 ppm (STEL)

Ventilation System

A system of local and/or general exhaust is recommended to keep employee exposures below the Airborne Exposure Limits. Local exhaust ventilation is generally preferred because it can control the emissions of the contaminant at its source, preventing dispersion of it into the general work area. Please refer to the ACGIH document, Industrial Ventilation, A Manual of Recommended Practices, most recent edition, for details.

Personal Respirators (NIOSH Approved)

If the exposure limit is exceeded and engineering controls are not feasible, a full facepiece respirator with an ammonia/methylamine cartridge may be worn up to 50 times the exposure limit or the maximum use concentration specified by the appropriate regulatory agency or respirator supplier, whichever is lowest. For emergencies or instances where the exposure levels are not known, use a full-facepiece positive-pressure, air-supplied respirator. WARNING: Air purifying respirators do not protect workers in oxygen-deficient atmospheres.

Skin Protection

Wear impervious protective clothing, including boots, gloves, lab coat, apron or coveralls, as appropriate, to prevent skin contact. Neoprene and nitrile rubber are recommended materials. Polyvinyl alcohol is not recommended.

Eye Protection

Use chemical safety goggles and/or full face shield where dusting or splashing of solutions is possible. Maintain eye wash fountain and quick-drench facilities in work area.

 

 

 

 


Company Details close-icon

Mysore Ammonia, with its origins from Mumbai, started as a family enterprise in 1962. Transforming over the years into a professional organization, it is today in the forefront of Ammonia Business in India and the Indian-Ocean Region with a presence in many other countries.
Mysore Ammonia was the first in India to start a Cylinder Filling Plant for Ammonia in 1979 and in 1984 was the first to start a Liquor Ammonia Manufacturing Plant in India. With a Long-Term outlook focused on Service, Quality and Safety, in the Ammonia Industry, Mysore Ammonia is known for Transparency in their interactions and good HR practices.
Respected for their business values, the Ethos of Mysore Ammonia is focused on Quality and Safety while their large volumes drive down costs. As a result of this potent combination Mysore Ammonia safely deliver a Quality Product at a Competitive Price providing Quality Service to their customers while persistently striving for continuous improvement of these services. They have implemented quality management systems in every function to achieve efficiency and effectiveness.
Only Indian Company sourcing Ammonia from the overseas besides India, and also the only Indian company with Manufacturing Plants and tie-ups for Production of Ammonia overseas, Mysore Ammonia is highly reputed in the industry for their Supply-Chain Management also. They follow their commitment to provide solutions as per customer needs and deliver where the Customers needs the Product; when they need it; and with consistent Quality & Quantity standards.
Customers normally have very low storage capacities though Ammonia is an essential chemical with various uses. Mysore Ammonia with their own Cylinders, Tanks, Trailers and Vehicles, combined with their Supply-Chain Management Systems, are the most reliable suppliers in every location they are presently supplying.
MYSORE AMMONIA has extensive expertise in regulatory matters pertaining to Anhydrous Ammonia and Ammonia Solution. They assist customers in Installation & Commissioning of their Storage tanks, equipment arrangement, Safety Training and in preparation of necessary regulatory documents as well as guide them in their compliance.
  • Nature of Business Manufacturer / Exporter / Supplier / Retailer
  • Number of Employees 50 - 100
  • Year of Establishment 1982
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for Aqueous Ammonia (Liquor Ammonia)?

Quantity
Seller Contact Details
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice