Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Manual Sliding Door Autoclave Sterilizer, for Laboratory Use, Certification : CE Certified, ISI Certified

Listing ID #6767539

20 Lakh - 30 Lakh / piece
Get Latest Price
  • MOQ 01 Piece
  • Country of OriginIndia
  • TypeAutoclave Sterilizer
  • CertificationCE Certified, ISI Certified, ISO 9001:2008
  • ApplicationLaboratory Use
  • Supply Type Exporter, Supplier
  • Preferred Buyer Location All Countries Except India
View More Details
Send Enquiry

Company Information

  • Member Since 1 Year
  • Nature of Business Manufacturer
  • GST No. 03AAFCG3197G1ZP

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Country of Origin India
  • Type Autoclave Sterilizer
  • Certification CE Certified, ISI Certified, ISO 9001:2008
  • Application Laboratory Use
  • Voltage 220V
  • Capacity 100-200ltr, Up To 3000 Liters
  • Frequency 60Hz
  • Power 2kw
  • Warranty 3yrs
  • Automation Grade Manual
  • Brand Name Alliance Elemech
  • Shape Sliding Door
  • Temperature 121- 134 Deg
  • Material Stainless Steel
  • Brand Genist Technocracy
  • Insulation Wall Triple wall
  • Available Sizes 600 X 600 MM to 1200 MM
  • Model No. GTA-006

Construction Construction Robust and rugged all weld construction which is leak-proof, unlike riveted construction. Chamber and jacket are made of a thick plate of stainless steel of 316. Pass a hollow load (A) test (batch Monitoring System), High Vacuum compressor with recycling facility.   Door The equipment provided with vertical sliding single/double door. The door is fabricated from SS 316 quality material, and sealing is done through a movable silicon gasket pressurized by compressed air. The pressure gauge is provided for a gasket.   Insulation Glass wool Insulation to surface temperature of the sterilizer to be less than 45°C and it has low thermal conductivity and should not release any particles.   Door Gasket Silicon Door gasket, and on commencement of the process, the door gasket is pressed against the rear face of the door by steam/air to ensure the doors remains closed during the process.   Control System with Connectivity Fully automatic microprocessor controlled horizontal steam sterilizer. PLC-based system has 4-5 color touch-sensitive, LCD display interface. With battery back-up & non-volatile memories. Digital input/output controls, analog measuring inputs & ports for PC connectivity. Panel include various pressure and temp. Display for the depiction of actual pressure/temperature in the chamber, jacket, and on the gasket.   Password Protection Monitoring & documentation system and multiple password access levels would be provided to control access/ operation of the machine preventing unauthorized access.   Printer Equipped with built thermal printer.   Door Safety The steam pressure in the boiler is indicated on an individual pressure gauge. Safety Lock for Door Every horizontal rectangular sterilizer is fitted with a SELF-LOCKING SAFETY DOOR, which cannot be opened when the chamber is under pressure.   Alarms Automatic process checking & failure correction. Self-diagnosis and check the autoclave for the different audio/visual alarm situations.   Other Safety Power to shut off heaters should water in the heating section falls below a preset level. The terminals & contacts are housed in a watertight cabinet. Electronic water saving control – condensing the exhaust chamber steam with drain system designed to prevent pollutants from entering water supply & sterilizer. Automatic process checking, and failure correction should be possible by the control system. The range of alarm should include over temperature pressure sensor failure, phase time out, doors not properly closed, power failure (less than 10 sec should be ignored), continuous self-checking of all the safety devices, low water level, water in the chamber, etc. should be possible.   Steam Generator Separate Steam generator of suitable capacity for each sterilizer made of 316 Stainless Steel. Fitted with all safety & control devices. Steam Generator has automatic operation for water level control energizes the water pump and supply valve to ensure proper water level in the boiler drum . Vacuum Electric vacuum system consists of a multistage vacuum pump with a liquid ring that ensures air removal during the pre-vacuum stage.   Temperature and Pressure Sensors Working temperature 121 °C to 134 °C To work on 440VAC, 50 Hz, 3 Phase Condensate free 97-100 % saturated vapor complete with piping, valves, and pressure relief etc., delivery at 50-80 PSIG pressure.   Air Filter A disposable air filter provided by filtering the atmospheric air for entering inside the chamber.   Cycle Designed to operate various programs. Apart from standard pre- programmed cycles, the special cycle should be programmed by an authorized supervisor code only.   Programs Include Wrapped instruments, porous load 134°C / Heat Sensitive material, rubber, plastic, porous load 121 °C (working holding temperature 121°C to 134°C) Bowie & Dick test (7kg), PCD test/ Leak test and equipped with pre-vacuum, gravity and preferably with liquid cycle (121 °C Liquid cycle for liqui construction.


Sizes

Size of Inner Chamber ( WXHXD ) Capcity in Liters Load
450X450X900 mm 180 Liters 18 KYV
450X600X900 mm 240 Liters 18 KYV
600X600X900 mm 320 Liters 18 KYV
600X600X1200 mm 430 Liters 27 KYV
600X900X1500 mm 810 Liters 27 KYV
Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry

Product Images

  • Sliding Door Autoclave Sterilizer
  • Sliding Door Autoclave Sterilizer
  • Sliding Door Autoclave Sterilizer

Company Details close-icon

We the “Genist Technocracy Pvt Ltd” is an organization committed to manufacturing and export of International quality Medical Equipment and Laboratory Equipments in India & abroad since 2004. We are dedicated to serve the Mankind and the Nation by providing World Class Medical Equipment and Laboratory Equipments at affordable prices.
  • Nature of Business Manufacturer / Exporter / Supplier
  • Number of Employees 50 - 100
  • Year of Establishment 2013
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for Sliding Door Autoclave Sterilizer?

Quantity
Seller Contact Details

Find Seller from near by Cities

Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice