Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    VAIBHAV COMBO DUST SAMPLER VCDS 320MFC, Rated Voltage : 220V

    ₹ 1.40 Lakh / Set
    Get Latest Price
    • MOQ1 Set(s)
    • Nominal Capacity1.0 Cubic Meter Per Minute
    • Rated Voltage220V
    • Power SourceElectric
    • Automation GradeAutomatic
    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 15 Years
    • building Nature of Business Manufacturer
    • gst icon GST No. 24AIOPS8140F1Z1

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • Nominal Capacity1.0 Cubic Meter Per Minute
    • Rated Voltage220V
    • Power SourceElectric
    • Warranty14 Month
    • Automation GradeAutomatic
    • TypeAir Samplers
    • ApplicationAir Sampling
    • Ambient Temperature SensorOne number Robust, corrosion-free polycarbonate small lightweight housing recommended for use in harsh environmental condition having measuring range from - 40oC to +65 oC, Resolution 0.1 oC,
    • PARTICULATE SAMPLINGat a constant 16.7 LPM (1m3/hour) unaffected by voltage fluctuation and filter chocking control through microprocessor base digital flow controller, provision for measurement of PM2.5 and PM10 flow st
    • Data Logger (Electronic Module & controller)Acceptance Testing : Flow Check, leak Check, Memory,
    • PM2.5 Filter Media46.2mm dia PTFE or equivalent filter media recommended in sampling method in a filter cassette housed in each stream of filter holder assembly fitted in the bottom of WINS impactor below of two stage
    • PM10 SIZE SEPARATIONSingle stage Impactor confirm to USEPA design, sample collected in a separate 46.2 mm diameter PTFE membrane filter fitted at the bottom having impaction inlet for cutoff particle greater than 10micro
    • PM2.5 SIZE SEPARATIONTwo stage Impactor confirm to USEPA design, sample collected in a separate 46.2 mm diameter PTFE membrane filter fitted at the bottom of WINS IMPACTOR having cutoff for particle greater than 2.5micron
    • Data Logger (Electronic Module & controller)Parameter Recording : Internal memory based system record all the parameters display on logger along with Station ID, Filter ID, Sampler start time etc..
    • PM10 Filter Media47mm dia Glass fiber filter / PTFE or equivalent filter media recommended in sampling method in a filter cassette housed in each stream of filter holder assembly fitted below single stage impactor.
    • GASEOUS POLLUTANT SAMPLINGFour inlet & one outlet with needle valves for flow control of each unit through 2.0 LPM acrylic body rotameter with 0.05 LPM graduation
    • PM2.5 & PM10 FILTER HOLDERDesign to hold 47mm dia filter media, separate filter holder for PM2.5 & PM10
    • Power RequirementSingle phase AC 220 volts, 50 Hz, sampler unaffected by +/- 10 % fluctuation in supply voltage.
    • Filter TemperatureTwo number Robust, corrosion-free polycarbonate small lightweight housing recommended for use in harsh environmental condition having measuring range from - 40oC to +65 oC, Resolution 0.1 oC, separate
    • Clock / Timer SystemProgrammable Real Time control system with control of automatic start & stop of instrument having digital display of current date and time, with total sample duration.
    • Data Logger (Electronic Module & controller)Time Totalizer : RTC based record the operating time for each sample in hours and minute. Also record instrument stoppage due to pre set control.
    • Data Logger (Electronic Module & controller)Parameter Display : Flow Rate of PM2.5 & PM10 channel, Volumetric Flow of PM2.5 & PM10 channel, Filter Temperature of PM2.5 & PM10 channel, Barometric Pressure, Filter Pressure of PM2.5 & PM10 channel
    • Data Logger (Electronic Module & controller)Volumetric Flow Rate compensation : Performed automatically by logger using sensor for Ambient Temperature, Barometric Pressure and filter pressures
    • Data Logger (Electronic Module & controller)Flow Totalizer : Automatically volume totalized using sample flow & running time in minute
    • Data Logger (Electronic Module & controller)Software : Data can be save in CSV or Excel format which can easy access in any operating system
    • Data Logger (Electronic Module & controller)Auto Operation : Auto shutoff if flow rate drops by more than 10 % from set value of 1m3/hr
    • Data Logger (Electronic Module & controller)Memory : Field facility available for copy, erase, view(last sample summary), available free space
    • Power InterruptionAutomatically log the instance of power interruption during sampling, on resuming power, the sampling shall automatically resume with the previously accumulated volume and runs for the remaining durat
    • Sample VolumeSeparate Cumulative volume for air to be measure for each particulate stream say for PM2.5 and PM10.

    special features

     microcontroller based data logger display and record air & filter temperature,

    filter pressure, barometric pressure, flow rate, air volume sampled, elapsed

    time

     auto shut off facility if flow rate falls below 16.70 lpm (1m3/hr), due to excess

    filter chocking, temperature variation, filter pressure etc.

     filter holders fitting in the sampler are done such so that these are remain

    suspended in air & thus not affected by heat of motor fitted in lower cabinet

    of the sampler, filter temperature records are available

     suitable for outdoor use with corrosion free lockable housing.

     design to runs continue 28 hours or more at constant flow rate of 1m3/hr

     display values of all parameters are upgraded every 30 seconds

     pm10 & pm2.5 filters are 47mm diameter thus having low operating cost, user

    friendly design, pump assembly is brushless and noiseless having low

    maintenance

     pm10 & pm2.5 impactor is based on usepa published standard design,

     meets the requirement of pollution control board for fine dust sampling

     microprocessor based controller maintain constant air sampling rate of 16.7

    lpm(1m3/hr.) even during filter chocking in high dusting area

     programmable timer to auto start and stop sampling

     data can be exported to pc in excel format using pen drive

     compact , portable, easy to operate & handle

     auto leak check

     arrangement for parallel gaseous sampling

     dual data recording, internal and in easy removable memory stick

     filter holder is design to accept any standard 47 mm diameter filter.

     state of the art indigenous instrument design to operate in harsh tropical

    environment

     programmable recording interval from 1 minute to 24 hours

     industrial grade tough & rouged construction

     system has in-built memory of storing data for more than 1000 samples at 5 minute recording interval for all the

    parameters. User selectable logging interval ranging from 1 minute to 99 minute.

     two part of cabinet and fitment of filter holder in the sampler are such so it remain suspended in air and remain close

    to ambient temperature at all the time even heat of motor fitted in lower cabinet of the sampler.

     oil free, brushless & less noise induction motor driven pump assembly is immune to voltage fluctuation & require zero

    maintenance.

     simultaneous sampling of 9 parameters like pm10, pm2.5, gaseous pollutant & heavy metals

     high 24 bit datalogger resolution

     microcontroller base instrument

     high accuracy & reliability

     paperless recording

     inlet of pm10 & pm2.5 impactor of are omni-directional

     


    Additional Information

    • Payment Terms L/C, D/PT/T
    • Port of DispatchCOMBO DUST SAMPLER WITH MASS FLOW CONTROLLER FOR PM2.5 & PM10
    • Delivery Time2 - 3 Week
    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry

    Product Images

    • VAIBHAV COMBO DUST SAMPLER VCDS 320MFC
    • VAIBHAV COMBO DUST SAMPLER VCDS 320MFC
    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for VAIBHAV COMBO DUST SAMPLER VCDS 320MFC?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice