    F701-C is a general-purpose weighing controller that is compatible with all weighing systems. This is a practical device excellent in cost effectiveness, which is equipped with the final discharge function allowing high-accuracy feeding and discharging weighing control and the weighing sequence function essential to hopper and packing scales. Installable is the interface that can be connected to PLCs or various peripherals such as BCD output, RS-232C and CC-Link.  
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 14 Years
    • building Nature of Business Retailer

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    ANALOG SECTION
    Excitation voltage10V DC ±5%, Output current; within 120mA (Up to 4 loadcells at 350Ω are parallel-connectable)
    Zero adjustment range0 - 2mV/V
    Rough adjustment: Digitally controlled via rough adjustment circuit
    Fine adjustment: Auto adjusting method via digital processing
    Gain adjustment range0.3 - 3.2mV/V
    Rough adjustment: Digitally controlled via rough adjustment circuit
    Fine adjustment: Auto adjusting method via digital processing
    Min. input sensitivity0.3μV / count
    AccuracyNon-linearity: within 0.01% FS 
    Zero drift: within 0.2μV/°C RTI
    Gain drift: within 15 ppm/°C
    Analog filterBessel low-pass filter (-12dB/oct.), Selectable from 2, 4, 6, 8 Hz
    A/D converterSpeed: 200 times/sec
    Resolution: 24 bit (binary)
     
    SETTING SECTION
    Setting items- High limit, Low limit, near zero, SP1, SP2, Compensation, over, under, final
    - Comparison inhibit time, judging time, complete output time, adjust feeding time, auto zero times, judging times. Auto free fall compensation regulation, analog filter, tare weight
    - Weighing function 1, weighing function 2, weighing function 3, sequence mode, function key inhibit, digital filter, motion detect, zero tracking period, zero tracking range
    - Balance weight value, capacity, min. scale division, net over, gross over, DZ regulation value, function selection, gravitation acceleration (area number input), gravitation acceleration (acceleration input)
    - D/A output mode, D/A zero output weight, D/A full scale, RS-485 I/F, ID number, RS-232C I/F, external function selection, setting value LOCK, restriction on the tare subtraction function
    - Input selection, output selection, CC-Link I/F Occupied station & Transmission speed, CC-Link I/F Station No.
    - Average weight, maximum weight, minimum weight, population standard deviation, sample standard deviation, number of data (n), latest accumulation date, Maximum-minimum (R), option substrate
    - Span calibration, equivalent input calibration, password input, zero calibration
     
    INPUT/OUTPUT SECTION
    External output signalTransistor’s open collector output (Emitter = COM terminal); Output is LO when transistor is ON. Near zero, SP1, SP2, SP3, under, over, Low limit, high limit, stable, weight alarm or error, go or complete, run or accumulation error
    External input signal

    ON when shorted to COM terminal by contact (relay, switch) or non contact (TTL-level transistor or open collector output) G/N, digital zero, tare subtraction ON, tare subtraction OFF, hold*, judge*, feed / discharge, start*, stop*, accumulation command*, accumulation clear*

    *Signals for selection. Up to 4 can be selected.

    Interface
    • SIF:
    • 2-wire type serial interface (standard); Interface to link with Unipulse printer or external display
    •  
    • 232:
    • RS-232C communication interface (standard): Write (change) / read weight data, various statuses and setting values by commands from a host computer
    •  
    • BCO:
    • BCD parallel data output interface (Optional): Parallel interface to transmit weight data to various peripherals
    •  
    • 485:
    • RS-485 communication interface (Optional): Allows longer-distance communication than RS-232C. ID numbers are set, and multiple units of F701-C are parallel-connectable.
    •  
    • DAC:
    • D/A converter interface (Optional); Interface to convert weight data to current signal and output it.
    •  
    • CCL:
    • CC-Link interface (Optional); Links directly to PLC.
     
    DISPLAY SECTION
    Display unitNumerical display (7 digits) with a character height of 10.4 mm by fluorescent display tube, Sub-display; character height 4.0 mm
    Display value5 digits, Sign; Minus sign displayed on most significant digit
    UnitSelectable from t, kg, g, N, lb, none
    Status displaySP1, SP2, SP3, NEAR ZERO, HOLD, ZERO ALARM, STAB, TARE, NET, ZERO, BATTERY CONDITIONS
     
    GENERAL SPECIFICATIONS
    Power supply voltage100 - 240V AC (+10% - 15%) (Free power supply 50/60 Hz)
    Power consumptionApprox. 15VA
    Operating conditionsTemperature: Working temperature range -10 - +40°C; Storage temperature range -20 - +85°C
    Humidity: 85% RH or less (non-condensing)
    External dimensions144 (W) x 72 (H) x 160 (D) [mm] (protruding parts not included)
    WeightApprox. 1.0 g
     















    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for Accumulation Value Display Weighing Controller?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice