Ac switch

Listing ID #3513864

  • Frequency50 (60) Hz, ±3%
  • Output Contact Rating30 Amp @ 240 V AC (RLY 1 & RLY 2) 5 Amp (for RLY 3)
  • System Supply240 V AC, ±20%, 1 Ph
  • Output Relay Contact1 NO + 1 NO + 1 NO
  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world
View More Details
Send Enquiry

Company Information

  • Member Since 21 Years
  • Nature of Business Retailer
  • Year of Establishment 1964

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Frequency 50 (60) Hz, ±3%
  • Current Setting 8-16 Amp (Variable)
  • Power ON Delay 2 mins., ±0.5 min (Fixed)
  • Output Relay Contact 1 NO + 1 NO + 1 NO
  • Output Contact Rating 30 Amp @ 240 V AC (RLY 1 & RLY 2) 5 Amp (for RLY 3)
  • System Supply 240 V AC, ±20%, 1 Ph

Protocom 1 is useful for two AC installations in small offices businesses, ATM centers, residential houses, for AC units of 1 or 1.5 Tons. In Logic One, only one AC is operated at a time and equal running of each AC is ensured during continuous operation. In Second logic, One or both ACs will run as per Demand. Built-in protection against UV, OV & OL for both AC units.
PROTOCOM - 1
Saves energy by alternatively using only one air conditioner (or both in case of temp rise) and that too only when it is required depending upon logic selected. Two Types of different operational logics can be selected with Protocom-1 through front Keys and display. These LOGICS are as follows.
During Logic # 1 operation :
Only one AC at a time will run for set time cycle in alternate mode. Changeover will take place only if
a) Cycle time is completed;
b) Running AC is tripped due to Overload;
c) Over Temp condition is present for more that 10 minutes.
If the room temperature keeps on rising even with the AC unit is in operation, it will energize OT alarm relay. It will stop running AC, ALARM LED will glow and switchover to another AC unit overriding present timing. Thus it also monitors and maintains the room temp.
During Logic # 2 operation :
One AC will be running as normal running AC for set time cycle. If temp rises above OT set point. second AC is switch on as stand-by running AC. This AC will be running until temp drops below OT-Hysteresis level (LIFO). In case, both AC are running and cycle time completes, none of the AC will be switch off or no change over will take place. However if temp drops below. OT-Hysteresis set point, first started AC will be made off and running AC will be considered as normal running AC (FIFO).


Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for ac switch?

Quantity
Seller Contact Details
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice
ac switch at Best Price in Pune - ID: 3513864 | Minilec India Pvt. Ltd.
Products / Services
  • Products / Services
  • Companies
  • Buy Leads
Post Buy Requirement

Ac switch

Listing ID #3513864

  • Frequency50 (60) Hz, ±3%
  • Output Contact Rating30 Amp @ 240 V AC (RLY 1 & RLY 2) 5 Amp (for RLY 3)
  • Power ON Delay2 mins., ±0.5 min (Fixed)
  • System Supply240 V AC, ±20%, 1 Ph
  • Supply Type Manufacturer, Exporter, Supplier
  • Preferred Buyer Location All over the world
View More Details
Send Enquiry

Company Information

  • Member Since 21 Years
  • Nature of Business Retailer
  • Year of Establishment 1964

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Frequency 50 (60) Hz, ±3%
  • Output Contact Rating 30 Amp @ 240 V AC (RLY 1 & RLY 2) 5 Amp (for RLY 3)
  • System Supply 240 V AC, ±20%, 1 Ph
  • Power ON Delay 2 mins., ±0.5 min (Fixed)
  • Output Relay Contact 1 NO + 1 NO + 1 NO
  • Current Setting 8-16 Amp (Variable)

Protocom 1 is useful for two AC installations in small offices businesses, ATM centers, residential houses, for AC units of 1 or 1.5 Tons. In Logic One, only one AC is operated at a time and equal running of each AC is ensured during continuous operation. In Second logic, One or both ACs will run as per Demand. Built-in protection against UV, OV & OL for both AC units.
PROTOCOM - 1
Saves energy by alternatively using only one air conditioner (or both in case of temp rise) and that too only when it is required depending upon logic selected. Two Types of different operational logics can be selected with Protocom-1 through front Keys and display. These LOGICS are as follows.
During Logic # 1 operation :
Only one AC at a time will run for set time cycle in alternate mode. Changeover will take place only if
a) Cycle time is completed;
b) Running AC is tripped due to Overload;
c) Over Temp condition is present for more that 10 minutes.
If the room temperature keeps on rising even with the AC unit is in operation, it will energize OT alarm relay. It will stop running AC, ALARM LED will glow and switchover to another AC unit overriding present timing. Thus it also monitors and maintains the room temp.
During Logic # 2 operation :
One AC will be running as normal running AC for set time cycle. If temp rises above OT set point. second AC is switch on as stand-by running AC. This AC will be running until temp drops below OT-Hysteresis level (LIFO). In case, both AC are running and cycle time completes, none of the AC will be switch off or no change over will take place. However if temp drops below. OT-Hysteresis set point, first started AC will be made off and running AC will be considered as normal running AC (FIFO).


Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for ac switch?

Quantity
Seller Contact Details
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice