Listing ID #6042792
Company Information
Ask for more detail from the seller
Contact Supplier
Scan Modes
A Scan
Application
Hospital
Brand
Matronix
IOL Formula
Hoffer Q, SRK 2, SRK T
Accuracy
-+0.1 mm
Dimension
200*168*165(mm,L*W*H)
power
45 VA
Examination modes
Normal,Aphakic,pseudophakic and dense cataract Measurement mode immersion and contact,auto and
Gain Adjustbale
0-120 db
IOL formulas
SRK-II,SRK-T,BINKHORST,HOLLADAY,HOFFER-Q,HAIGIS
Light
Red-Light A-Scan probe 10MHz
Measurement range
0.23-1.20 mm
Measurements
ACD,Lens,Vitreous and AXL
Measurements Range
15-35 mm (vel 1640 m/s)
Power requirement
AC 100-240V 50-60 Hz Rate power - 45 VA
Probe Frequency
10 MHz
Probe frequency Pachy Meter
20 Mhz
Resolution
0.01 mm
Show actual value and deviation at the same timeSensitive, convenient, accurate and fast measurementThe Probe service life is long, better cost performance Point and surface point measurementCabinet and delicate foot switch, convenient operationCalculate the calibration value of intraocular pressure (after achieving accurate intraocularpressure)Ultrasonic velocity and offset is adjustable compare measuring results with other equipmenteasily.5.7’ color LCD touch screen, and user information can be easily input, more convenient andquick.A-Scan Bio meter measurement integration of AL measurement and IOL calculation . reading average and standard deviation improve reading accuracy and liability 4 automatic measuring mode: normal. Cataract ,aphakic and special.
IOL Calculation:-
SRK-II, SRK-T, BINKHORST, HOLLADAY, HOFFER-Q, HAIGIS, any of two groups can control display. Calculate IOL,DEM,DAM, REEF, etc. And long term save 100 groups of measurement results of A scan.Specifications AddedEdit
Accuracy:
-+0.1 mm
Application:
Hospital
Brand:
Matronix
Dimension:
200*168*165(mm,L*W*H)
Examination modes:
Normal, Aphakic, pseudophakic and dense cataract Measurement mode immersion and contact , auto and
Gain Adjustable:
0-120 dB
Gain Adjustbale:
0-120 db
IOL formulas:
SRK-II,SRK-T,BINKHORST,HOLLADAY,HOFFER-Q,HAIGIS
Light:
Red-Light A-Scan probe 10MHz
Measurement range:
0.23-1.20 mm
Measurements:
ACD,Lens,Vitreous and AXL
Measurements Range:
15-35 mm (vel 1640 m/s)
Power requirement:
AC 100-240V 50-60 Hz Rate power - 45 VA
Probe Frequency:
10 MHz
Probe frequency Pachy Meter:
20 Mhz
Resolution:
0.01 mm
power:
45 VA
Accuracy: | -+0.1 mm | Application: | Hospital |
---|---|---|---|
Brand: | Matronix | Dimension: | 200*168*165(mm,L*W*H) |
Examination modes: | Normal, Aphakic, pseudophakic and dense cataract Measurement mode immersion and contact , auto and | Gain Adjustable: | 0-120 dB |
Gain Adjustbale: | 0-120 db | IOL formulas: | SRK-II,SRK-T,BINKHORST,HOLLADAY,HOFFER-Q,HAIGIS |
Light: | Red-Light A-Scan probe 10MHz | Measurement range: | 0.23-1.20 mm |
Measurements: | ACD,Lens,Vitreous and AXL | Measurements Range: | 15-35 mm (vel 1640 m/s) |
Power requirement: | AC 100-240V 50-60 Hz Rate power - 45 VA |