Products / Services
  • Products / Services
  • Companies
  • Buy Leads
    Post Buy Requirement

    Glass Coil Condenser, For Industrial Use, Voltage : 380V

    • MaterialGlass
    • Weight7-105kgs
    • Voltage380V
    • ApplicationIndustrial Use
    • Supply TypeManufacturer, Exporter, Supplier
    • Preferred Buyer Location All over the world
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 9 Years
    • building Nature of Business Retailer
    • gst icon GST No. 24AATCA4996M2ZQ

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    • MaterialGlass
    • ApplicationIndustrial Use
    • Weight7-105kgs
    • Voltage380V
    • FeaturesDurable
    • Keep the Maximum Coolant Pressure to2.7 Bars.

    Coil Condensers

    Coil Condensers are commonly used for the process of vapor condensation as well as examines the cooling of liquids. Condensers are manufactured by binding many parallel coils together in a glass shell. These coils are built of different diameters using various bore tubes.

     

    Design of Coil Condenser

    The Coil condensers are commonly used to separate or remove heat from refrigeration or an air-conditioning system. Occasionally they are accustomed to the intention of heating the air streams. Coil condensers are among the four essential components in an air-conditioning or the refrigeration cycle. The refrigerant then enters the system as a superheated gas and gets condensed in the coil tubes. The refrigerant then leaves the coil in the form of a liquid.

     

    Methods of Using the Coil Condensers

    Vapors from bottom

    It is effortless to install the Vapor method over a reactor. However, it may result in the condensate to return at its condensing temperature. You must be careful while working with this method that the condensate must not be in excess, and it must not lead to the blocked coils and create back pressure. Usually, the use of a reflux divider is advised to be installed below the condenser that will take the distillate out.

     

    Boilers

    Boilers are usually used for the evaporation process carried out for various liquids by passing the hot steam through the coils. Boilers are manufactured by combining many parallel coils in a glass shell. The coils in the boilers are specially designed to provide you with a much bigger cross-section than Condensers.

     

    Angled Hose Connector Assemblies

    Angled hose connector assemblies are usually made from either metal or plastic and must connect the condensers to the flexible hose. These can be provided with a rubber gasket, a mating flange, and nut bolts.

     

    Immersion

    Immersion-type heat exchangers are generally used to control the exothermic reaction happening in the glass vessels. Immersion-type heat exchangers can be used along with the vessels that have a bigger and wider bottom outlet. Such heat exchangers come with a central hole in the coil battery so that a stirrer can be mounted at the bottom of the heat exchanger.

     

    In most of the applications, the cooling water is usually used in the coils with a maximum pressure of 2.7 bar g; you can also use them along with the hot steam having a maximum pressure of 3.5 bar g. In the latter case, all the coils are entirely immersed in the liquid. Immersion procedure is not advised to use with the products having crystallization tendency.

     

    Product coolers

    Product coolers are generally used to cool various types of liquids that are used for the process of cooling the distillates in the distillation system. Unlike other coil condensers, among the product coolers, the product passes through the coil battery, and the coolant passes through the shell. This transfer process will give the product more time to get cooled.

     

    Preventive measures while using coil condensers

    • Let the vapors pass via shell only.
    • Keep the maximum coolant pressure to 2.7 bars.
    • Coolant flow must be adequate for the process.
    • The use of steam in the coil is prohibited.
    • Coolant must be heated but not to its boiling point.
    • Turn the coolant control valve slowly.
    • Let the coolant drain freely.
    • You can use coils made from brine in a closed circuit.
    • Connect the water main to a flexible hose.
    • Ensure water left in the coil doesn’t freeze.
    • Condensers must be mounted only in a vertical position

     

    Final Thoughts

    Ablaze Export Pvt. Ltd. is one of the leading Coil condensers manufacturers in India. We are into the production of many standard chemical process equipment as well as we also provide customized process equipment. We have years of experience serving customers across India as well as delivering our products across the world.


    Dimension Table

    Heat Transfer Area (HTA)------Jacket Coolant*FCSACAT. REF.
    (m2)DND/DN1LL1L2TypeCap. Ltr.Rate Kg/hSHELL (cm2) 
    0.2401660085100A17504.5AHE1.5/2
    0.35501660090100A1.2513005AHE2/3.5
    0.35801660090100A213005AHE3/3.5
    0.510019600120100A4240030AHE4/5
    0.610019750120100A6240030AHE4/6
    115025600150100B9260052AHE6/10
    2.530025600250125B255700175AHE12/25
    430025900250125B355700175AHE12/40
    440025600265125B606200450AHE16/40
    540025700265125B706200450AHE16/50
    645040750325150B/C1004800820AHE18/60
    845040900325150B/C1106200820AHE18/80
    Interested in this product? Ask for more details & Latest Price from seller
    Send Enquiry

    Product Video

    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for Glass Coil Condenser?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice