Respirable Dust Sampler - VRDS 500DxNL, Feature : Durable, Eco Friwndly, Fine Finished, Precise Design

Listing ID #4147146

90,500 / Piece
Get Latest Price
  • FeatureDurable, Eco Friwndly, Fine Finished, Precise Design
  • Warranty14 MONTHS
  • DisplayDigital, ANALOG (OPTIONAL)
  • Flow Rate0.5-1m3, 1-1.5m3
  • Supply Type Exporter, Supplier, Retailer
  • Preferred Buyer Location All over the world
View More Details
Send Enquiry

Company Information

  • Member Since 14 Years
  • Nature of Business Manufacturer
  • GST No. 24AIOPS8140F1Z1

Ask for more detail from the seller

Contact Supplier

Product Details no_img_icon

  • Feature Durable, Eco Friwndly, Fine Finished, Precise Design
  • Warranty 14 MONTHS
  • Display Digital, ANALOG (OPTIONAL)
  • Flow Rate 0.5-1m3, 1-1.5m3
  • Automation Grade Fully Automatic
  • Brand Name VAIBHAV
  • Power AC
  • Type Respirable Dust Sampler, RESPIRABLE DUST SAMPLER
  • Weight 30-40kg
  • Voltage 220V
  • Condition New
  • Time Recorder 0 to 99999.99 hrs. time totalizer records the running time in hours
  • Clock / Timer Programmable Real Time control system with control of automatic start & stop, number of required intervals can be programmed, Timer is used to start and shut off the sampler at preset time
  • Sampling Time 30 hours (maximum)
  • Auto Zero of Volume By pressing single key volume will be auto zero
  • Flow Control.. When dust load increases beyond the capacity of the blower the flow rate will begin to decrease and the system will automatically be shutdown if the flow rate tends to drop below 15% of pre set level
  • Suction Blower.. Dynamically balanced, Brushless, regenerative, belt less almost maintenance free & zero consumable noise less turbine blower with little noise.
  • Filter Media 8inch X 10inch (203mm X 254mm / 20.3cm X 25.4 cm) Glass microfiber filter for common use and EPM 2000 or equivalent for special monitoring / research work
  • Digital Manometer Digital display of manometer flow on 16 character, 2 line LCD display. Flow indication in two digit with 3 decimal places & volume tantalization indication in five digit with 2 decimal place.
  • Power Requirement Single phase AC 220 volts, 50 Hz, sampler unaffected by +/- 10 % fluctuation in supply voltage. For proper operation and safety a good earth connection is mandatory
  • Filter Holder To accommodate any standard filter paper of 20.3cm x 25.4cm (8inchX10inch) in size, particulate bigger than 10 micron collected in separate dust cap under the cyclone
  • IS Reference Match the requirement prescribed in BIS 5182(Part-23) 2006
  • Dimension Approximately 410mm X 300mm X 700mm
  • Particulate Sampling.. RSPM is accumulated on the filter paper (8”X10” size) while coarse dust is collected in a cup placed under the cyclone
  • Suction Blower.. Multi bladed impeller revolves at a very high speed in a specially designed stator cum compression chamber ensuring very fine clearance between them
  • Special Feature Design as per Indian standard BIS 5182(Part 23):2006,digital flow indicator & volume totalizer, waterless manometer eliminate filling of distilled water & maintaining zerolevel in glass manometer tube
  • Construction The body of RDS is robust enough to withstand impacts and vibration in transportation, it is made of heavy aluminum sheet.
  • Flow Control The system will automatically maintain the flow rate constant and compensate for dust load deposited on the filter.
  • Hardware Only SS corrosion free hardware used in sampler
  • Special Feature.. Electronic flow controller, Sampling flow will maintain the pre set level even during filter chocking, ampere and voltage variation, instrument will auto shut if flow vary from set flow & time limit.
  • Suction Blower... The impeller is fitted directly onto a bearing mounted shaft of a superior quality flanged electric motor. 100 % oil free required zero lubrication
  • Night View Provision has been made for light in the sampler for taking reading during dark area and in night hours
  • Particle Size Separate provision for collection of Respirable and non Respirable (less than and greater than 10 micron) size particles
  • Particulate Sampling 10 micron down to 0.1 micron (depending upon type of filter used). A cyclone is used for fractionating the dust into two fractions, D-50 cutoff for the cyclone is at 10 microns.

special features

 confirm to bis 5182 (part 23) : 2006 standard

 sampling flow rate will maintain automatic at pre set level even during filter chocking, ampere & voltage variation with electronic feedback controller

 digital manometer with volume totalizing (waterless manometer, no need of filling and adjusting zero lever with distilled water)

 digital manometer eliminated glass manometer tube brakeage & water evaporation during sampling

 flow will be readout upto to three decimal place.

 provide sample volume in at any stage of sampling on display

 sturdy aluminum construction with ss hardware

 little noise during operations

 maintenance free brushless regenerative heavy duty induction suction assembly

 totally eliminated of electromagnetic interference (emi) to tvs is totally eliminated

 blower immune to voltage fluctuations thus eliminating need of voltage stabilizer

 compact, portable, easy to operate-transport & handle

 arrangement for parallel gaseous sampling

 light provision for working in night & dark area

 design to runs continuously 24 hours or more

 modular design for easy operation

 suitable for outdoor use, corrosion free lockable housing

.


Additional Information

  • Payment Terms L/C, D/PT/T
  • Port of Dispatch AHMEDABAD
  • Delivery Time READY STOCK
Interested in this product? Ask for more details & Latest Price from seller
Send Enquiry

Product Images

  • Respirable Dust Sampler - VRDS 500DxNL
  • Respirable Dust Sampler - VRDS 500DxNL

Company Details close-icon

Manufacturer & Suppliers of Air Monitoring Instrument like Stack Emission Sampler, Respirable Dust (PM 10) Sampler, Fine Dust (PM 2.5) Sampler, Combo (PM 10 & PM 2.5) sampler, Handy Sampler, Personal Sampler, Flue Gas Analyzer, Weather Station, Sound Level Meter, NOx Apparatus, Chemical Kit, Online dust monitoring instrument
Field Training and service support of air monitoring instrument
Calibration of Air Sampling / Monitoring Instrument
Maintenance Contract of Air Monitoring Instrument
Rent / Higher Service of Air Sampling / Monitoring Instrument
  • Nature of Business Manufacturer / Exporter / Service Provider / Supplier / Retailer
  • Number of Employees Below 20
  • Year of Establishment 1994
Tell us your Buy Requirement to Get Instant Response
Tell us what you need?

By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

Looking for Respirable Dust Sampler - VRDS 500DxNL?

Quantity
Seller Contact Details
Waiting for permission
To search by voice, go to your browser settings and allow access to microphone

Allow microphone access to search with voice