    2-position Remote Solenoid Valve

    • Supply TypeManufacturer, Exporter, Supplier, Retailer
    • Preferred Buyer Location All over the world

    Application: Single or double-acting cylinders. Actuation: 9593, 9524 and 9554 are solenoid operated. Operation with single-acting cylinder: Either oil port “A” or “B” must be plugged on....
    View More Details
    Send Enquiry

    Company Information

    • calendar Member Since 14 Years
    • building Nature of Business Retailer
    • Year of Establishment 2003

    Ask for more detail from the seller

    Contact Supplier
    Report incorrect details
    • Product Details

    • Company Details

    no_img_icon

    Application: Single or double-acting cylinders. 
    Actuation: 9593, 9524 and 9554 are solenoid operated. 
    Operation with single-acting cylinder: Either oil port “A” or “B” must be plugged on valve. With port “B” plugged, solenoid is energized to position “A,” oil port “A” becomes pressurized. When solenoid is energized to position “B,” oil port “A” becomes the return port. 
    Operation with multiple single-acting cylinders: A pressure line from one bank can be connected to oil port “A” and the other to oil port “B” on the valve. Sequence: When energized to position “A,” oil port “A” becomes pressurized and clamps the fixture connected to oil port “A”; oil port “B” becomes a “return” port for cylinder connected to oil port “B,” and retracts it. The opposite happens when solenoid “B” is energized. 
    Operation with double-acting cylinder: Port “A” is connected to “advance” port of cylinder, oil port “B” connects to cylinder “return” port. Solenoid is energized to position “A,” oil port “A” becomes pressurized to extend cylinder piston. The opposite happens when solenoid “B” is energized. Valve does not hold in “retract” position. 
    NOTE: When using more than one valve on a pump, the tank port may require a check valve (9580) to permit inadvertent, momentary extension of a retracted cylinder. 
    NOTE: If pump is equipped with an internal outlet check, a “hold” position can be maintained with the pump shut off. 
    NOTE: Valves are shipped without control switch. 
    For valves 9524, 9554 and 9593, use Remote Hand Control (No. 304718). 
    For valve 9595, use Remote Hand Control (No. 209593). 
    NOTE: Valves have 1/4" NPTF ports. 3/8" to "1/4" adapters are included. 
    NOTE: Maximum tank line pressure for remote mounted valves is 500 psi. 
    NOTE: Valves are shipped without control switch. Use Remote Hand Control (No. 202777). 
    CAUTION: To prevent sudden, uncontrolled descent of a load as it is being lowered, use a Load Lowering Valve (No. 9596) or Counter Balance Valve (No. 9720) in conjunction with the directional valve used in your application.



    Order No.Cylinder 
    Application *
    OperationValve TypeVoltAdvance / ReturnAdvance / Hold ReturnPosi-Check® FeatureWeight (lbs.)
    9524S.A. & D.A.Solenoid3/4-way, 2 Pos.230NoYesNo15.4
    9554S.A. & D.A.Solenoid3/4-way, 2 Pos.24NoYesNo15.4
    9593S.A. & D.A.Solenoid3/4-way, 2 Pos.115NoYesNo15.4
    * “S.A.” represents single-acting cylinders, “D.A.” represents double-acting cylinders

    Share your requirements for a quick response!
    Tell us what you need?

    By clicking Get Quotes Now, I accept the T&C and Privacy Policy.

    Looking for 2-position Remote Solenoid Valve?

    Quantity
    Seller Contact Details
    Waiting for permission
    To search by voice, go to your browser settings and allow access to microphone

    Allow microphone access to search with voice