Company Information
Ask for more detail from the seller
Contact SupplierZones Number: 28 wireless, 2 hardwired (zones 29 & 30).
Hardwired Zone Requirements:2.2 kΩ E.O.L. resistance (max. resistance of wires 220 Ω).
Zone Types: Interior follower, interior, perimeter, perimeter follower, delay 1, delay 2, 24h silent, 24h audible, fire, nonalarm, emergency, gas, flood, temperature and interior /perimeter.
Display: Single line, Backlit 16-character LCD.
Alarm Types: Silent alarm, siren alarm or sounder (internal) alarm, in accordance with zone attributes.
Siren Signals: Continuous (intrusion / 24 hours / panic); triple pulse - pause - triple pulse... (fire).
Siren (bell) Timeout:Programmable
Internal Sounder Output: At least 85 dBA at 10 ft (3 m)
Supervision: Programmable time frame for inactivity alert
Data Retrieval: Status, alarm memory, trouble, event log.
Compliance with U.S. Standards: Meets FCC Part 15 and Part 68 requirements. Ul1637, UL1635, UL1023, UL985, ULC-S545-02, ULC C1023.
Receiver Type: Super-heterodyne, fixed frequency
Receiver Range: 600 ft (180 m) in open space
Antenna Type: Spatial diversity
Coding: PowerCode and/or CodeSecure™
Power Supply: Internal switching power supply 100VAC to 240VAC, 50/60 Hz, 0.5A / 12.5 VDC, 1.6A.
Maximum Output Ripple: 0.05
Current Drain: Approx. 40 mA standby, 1400 mA at full load and in alarm.
Site External Siren Current (EXT): 450* mA max @ 10.5 VDC minimum when powered by AC & DC (battery).
Site Internal Siren Current (INT): 450* mA max. @ 10.5 VDC minimum when powered by AC & DC (battery)
PGM Output Current: 100* mA max.
Wired Detectors (zones 29 & 30)
Total (Sum) Current: 36* mA max.
High Current / Short Circuit Protection: All outputs are protected (automatic reset fuse).
Total Pro Panel output current: 550 mA.