Measuring Instruments & Equipment #4705847

Electromagnetic Flow Meter

  • Min. Order (MOQ) 1 piece
  • Type Integral / Remote Mounting
  • Accuracy + 1% (10 % to 90 % of calibrated range in ref. conditions
  • Repeatability + 0.2 % of reading
  • Brand Name Brio Instruments
  • Enclosure Aluminum Die-cast - for Amplifier / Transmitter
  • Dimensions Head Mount: 100 mm (L) x 160 mm (W) x 80 mm (D)
  • Cable Entries nos. for remote / integral Transmitter
  • Cable Glands PG-7 [Standard]
  • Power Supply 110V/ 220 V AC 50 Hz S.P
  • Temperature 0—50 °C (Operating Ambient)
  • Temp. Drift 0.010 %/ °C
  • Humidity 90 % R.H. max. Non-condensing
  • Input Micro-volt signal proportional to flow rate from Flow Tube
  • Outputs 4— 20 mA dc in max. 110 Ohms— Proportional (0 — 100 % flow rate)
  • Flow Rate Unit m?/hr, LPH, LPM & LPS
  • Totalize Unit Lit & m3
  • Min. Media 5 uSiemens / cm (Conductivity)
  • Coil Excitation Pulsed DC
  • Ref. Conditions Power supply nominal + 10% Temperature 27°C + 2°C
  • Ingress Protection IP — 65 Equivalent

We are leading manufacture for Electromagnetic flow meter in process control instrumentation; Maintenance free, low cost, highly stable, reliable & ideal flow meter suitable for wide ranges of pressure & temperature . The measurement being based on 'Faraday's law of electromagnetic induction' is independent of viscosity, density, pressure and temperature of the flowing media & measurement is a true volumetric. Current output of 4 – 20 mA DC is provided which is directly proportional to the instantaneous volumetric flow rate.

Advantages and Disadvantages:

  • A magnetic flow meter provides an unobstructed flow path, with negligible pressure drop due to its pipe The typical accuracy for a magnetic flow meter is + 0.5 % of full scale. This is among the best of the various pipe flow meters.
  • The effect of fluid viscosity on flow through a magnetic flow meter is essentially the same as for flow through the pipe itself.
  • The magnetic flow meter can be used for pipe flow measurement of either clean or dirty liquids, including wastewater, corrosive liquids, or slurries.

Disadvantages of Meter:

  • The magnetic flow meter is used primarily for liquids. It doesn't work well for measurement of gas flow rate.
  • In order to use a magnetic flow meter for measurement of a liquid's flow rate, that liquid must be conductive.

Brochure


Download Detail File : Click Here
View Complete Details

Paddle Wheel Flow Meter

  • Min. Order (MOQ) 1 piece
  • Brand Name Brio Instruments
  • Flow-rate range 0.5m/sec to 5m/sec.
  • Accurancy +/-1% of full scale deflection.
  • Cacle length 5 meters
  • Input Voltage 5 to 12 VDC (Optional 24VDC)
  • Output Voltage Square AVE (Sinking) of 5-12V Open coil o/p amplitude, 15-17.5 Hz/meter/second
  • Protecting Rating IP-65
  • Operating Temp. PP Sensor-upto 60C°C SS Sensor -upto 100°C
  • Operating Pressure PP Sensor-0-10 Kg/cm2 SS Sensor -0 to 20 Kg/cm2 100°C

Model Pw 101 & PW 102- Flow Sensor is a Paddle Wheel insertion type flow sensor in a compact housing. This sensor works onn the Faraday, s law of electromagnetic induction . It generates a frequency & signal proportional to the flow . The sensor gives excellent and reliable results in the flow velocity range of 0.5m/sec to 5 m/sec & for the flow with Reynolds no greater than 5000.

Brochure


Download Detail File : Click Here
View Complete Details

Tds Meter

900 - 1,000 /Piece Get Latest Price
  • Feature Top performance, Durable nature, Low maintenance required, Excellent in work, Nominal prices
  • Brand Name Brio Instruments
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Manufacturer of Measuring Instruments & Equipment from Pune, Maharashtra by Prerna Enterprises
Post Buy Requirement
Prerna Enterprises
Pune, Maharashtra, India
gstGST : 27AICPJ8016B1ZP Verified Add Review

Measuring Instruments & Equipment #4705847

Electromagnetic Flow Meter

  • Min. Order (MOQ) 1 piece
  • Type Integral / Remote Mounting
  • Accuracy + 1% (10 % to 90 % of calibrated range in ref. conditions
  • Repeatability + 0.2 % of reading
  • Brand Name Brio Instruments
  • Enclosure Aluminum Die-cast - for Amplifier / Transmitter
  • Dimensions Head Mount: 100 mm (L) x 160 mm (W) x 80 mm (D)
  • Cable Entries nos. for remote / integral Transmitter
  • Cable Glands PG-7 [Standard]
  • Power Supply 110V/ 220 V AC 50 Hz S.P
  • Temperature 0—50 °C (Operating Ambient)
  • Temp. Drift 0.010 %/ °C
  • Humidity 90 % R.H. max. Non-condensing
  • Input Micro-volt signal proportional to flow rate from Flow Tube
  • Outputs 4— 20 mA dc in max. 110 Ohms— Proportional (0 — 100 % flow rate)
  • Flow Rate Unit m?/hr, LPH, LPM & LPS
  • Totalize Unit Lit & m3
  • Min. Media 5 uSiemens / cm (Conductivity)
  • Coil Excitation Pulsed DC
  • Ref. Conditions Power supply nominal + 10% Temperature 27°C + 2°C
  • Ingress Protection IP — 65 Equivalent

We are leading manufacture for Electromagnetic flow meter in process control instrumentation; Maintenance free, low cost, highly stable, reliable & ideal flow meter suitable for wide ranges of pressure & temperature . The measurement being based on 'Faraday's law of electromagnetic induction' is independent of viscosity, density, pressure and temperature of the flowing media & measurement is a true volumetric. Current output of 4 – 20 mA DC is provided which is directly proportional to the instantaneous volumetric flow rate.

Advantages and Disadvantages:

  • A magnetic flow meter provides an unobstructed flow path, with negligible pressure drop due to its pipe The typical accuracy for a magnetic flow meter is + 0.5 % of full scale. This is among the best of the various pipe flow meters.
  • The effect of fluid viscosity on flow through a magnetic flow meter is essentially the same as for flow through the pipe itself.
  • The magnetic flow meter can be used for pipe flow measurement of either clean or dirty liquids, including wastewater, corrosive liquids, or slurries.

Disadvantages of Meter:

  • The magnetic flow meter is used primarily for liquids. It doesn't work well for measurement of gas flow rate.
  • In order to use a magnetic flow meter for measurement of a liquid's flow rate, that liquid must be conductive.

Brochure


Download Detail File : Click Here
View Complete Details

Paddle Wheel Flow Meter

  • Min. Order (MOQ) 1 piece
  • Brand Name Brio Instruments
  • Flow-rate range 0.5m/sec to 5m/sec.
  • Accurancy +/-1% of full scale deflection.
  • Cacle length 5 meters
  • Input Voltage 5 to 12 VDC (Optional 24VDC)
  • Output Voltage Square AVE (Sinking) of 5-12V Open coil o/p amplitude, 15-17.5 Hz/meter/second
  • Protecting Rating IP-65
  • Operating Temp. PP Sensor-upto 60C°C SS Sensor -upto 100°C
  • Operating Pressure PP Sensor-0-10 Kg/cm2 SS Sensor -0 to 20 Kg/cm2 100°C

Model Pw 101 & PW 102- Flow Sensor is a Paddle Wheel insertion type flow sensor in a compact housing. This sensor works onn the Faraday, s law of electromagnetic induction . It generates a frequency & signal proportional to the flow . The sensor gives excellent and reliable results in the flow velocity range of 0.5m/sec to 5 m/sec & for the flow with Reynolds no greater than 5000.

Brochure


Download Detail File : Click Here
View Complete Details

Tds Meter

900 - 1,000 /Piece Get Latest Price
  • Feature Top performance, Durable nature, Low maintenance required, Excellent in work, Nominal prices
  • Brand Name Brio Instruments
View Complete Details