Our Complete range of products are Solar Power System, Three Phase Online UPS, Power Pack Inverter Battery, Solar Inverters and Three-phase oil-cooled Voltage stabilizer.
Its the main component of the solar power system. These plates contain multiple silicon wafer cells are attached in series and parallel form. It generates DC power which flows to the inverter. It comes with multiple types like poly-crystalline, Mono-crystalline, etc
Solar panel efficiency increased in the last few years due to continuous research and development, Its a great option for carbon-free energy generation in the emerging crisis of global warming.
Due to negligible maintenance and affordable cost, the importance of solar panels is increasing day by day.
This Online UPSis extremelyuseful for offices, labs to run computersalongsideprinters and few lightsjust in caseofan influenceoutage foran extendedtime. The output of this Online UPS is regulated purewavewith low noise using high power IGBT modules.
This Online UPS can run Desktop computers, matrixprinters, laser printers, flex printing machines, and machinesutilized inlaboratories. With LCD displayyoullread input, output voltagealsoas output and battery charging current.
Programming is providedto pickpower battery type, battery charging current, and inverter on warning.
Features :
Type | Three Phase In One Phase Out Online UPS | |
Model | 6 KVA – 25 KVA | |
Input AC | Voltage range | 415 V +/- 5 % |
Type | 3 Phase 4 Wires | |
Frequency | 48 – 52 Hz | |
PF | 0.8 – 0.9 | |
Battery | Voltage | 144 V – 360V |
Charging Current | 4 – 10 Amps | |
Type | SMF / Tubular | |
Boost Cut-off Voltage | 13.8 V for SMF Battery / 14.4 V for Tubular Battery | |
Battery Low ea trip early warning | 10.8 Volts | |
Battery low trip | 10 V | |
Output | Waveform | Pure Sine wave |
THD | 3 % for linear load / 5 % for Non linear load | |
Crest Factor | 1:03 | |
Frequency | 50 Hz +/- 0.5 Hz | |
Voltage | 230 V AC +/- 2% | |
PF | 0.8 lagging | |
Galvanic Isolation | With Isolation Transformer | |
Inverter | Technology | Center Align HF PWM |
Switching Device | IGBT Modules | |
Galvanic Isolation | With Isolation Transformer | |
Charger | Technology | Phase Control |
Switching Device | Thyristor Modules | |
Protections | Input | MCB |
Output | Electronic trip for overload and short circuit | |
Battery reverse polarity | Fuse link / HRC fuse | |
Indications | LCD | Input, Output and Battery Voltage |
Output and Battery Charging Current | ||
LEDs | Mains OK, Inverter On, Overload, Charging On | |
Battery Low, System On | ||
Audio | Batter low trip early warning | |
Overload trip early warning | ||
Mains fail warning | ||
Bypass Switch | Manual | Electromechanical |
The inverter is the second most important component in the solar power system. This converts the DC power generated from the panel to AC Power, which is usable for our house load. There are two types of inverter comes one is off-grid and the second on-grid comes in single-phase, and three-phase types depending on the users specification.
Specifications:
Range : 50 kva 200 Kva
Voltage Rating: Designed for Three-Phase power supply systems.
Input Voltage Range: Typically designed to handle variations in input voltage, e.g., 340V-460V for a 400V system.
Output Voltage: Provides a stable and regulated output voltage within a narrow range, e.g., +/- 1-3% of the rated output voltage.
Capacity (in VA or kVA): Specifies the maximum load it can handle, such as 10 kVA, 20 kVA, 50 kVA, etc.
Topology: Utilizes oil-cooled technology for efficient heat dissipation and voltage regulation.
Cooling Method: Employs oil as a cooling medium to dissipate heat generated during voltage regulation.
Coolant Type: Specifies the type of coolant used, such as mineral oil or synthetic oil.
Display: Often equipped with an LED or digital display to show input and output voltage levels.
Phase Configuration: Designed for balanced or unbalanced load conditions.
Protection Features: Includes features like over-voltage protection, under-voltage protection, short-circuit protection, and overload protection.
Efficiency: Typically designed to be highly efficient, reducing energy consumption.
Response Time: Offers rapid response to voltage fluctuations to ensure minimal disruption to connected equipment.
Operating Temperature: Specifies the range of temperatures in which it can operate effectively, often wider due to efficient cooling.
Oil Level Indicator: Includes an indicator to monitor the oil level to ensure proper cooling.
Exide SMF batteryis one of the most used batteries forUPS Systemsin India.
Generally, the SMF battery is used for a wide range of applications with considered the most preferred battery for the Online UPS system.
Life of SMF battery
If we consider the SMF battery installed in the online UPS system, then the batteries are in use for 24 hours. According to the data collected, this lasts for 3 to 5 years.
Specification
Download or view the following data for Exide battery technical specification
ExideInverter batteryis the most popular and appreciated battery in India in terms of quality and service by customers.Exidebrings innovative products through advanced manufacturing process, continuous research and development.
In simple words, a battery is called an electricity storage device. It is the third most major component in a solar power system. The off-grid solar system is incomplete without a battery.
How big should the battery be in ah? Which one is best? It decides based on the panels watt, quantity, and the size of the inverter with the required backup time.
Batteries also come in various types like lead-acid batteries, lithium batteries, VRL batteries, etc.
It is mainly used for computers and servers. These UPS are largely sold through various channels to customers.
Features :APC UPS system is a device that needs to be installed for the protection of case-sensitive applications and better equipment life. In todays age of modernization, the importance of the UPS System has increased a lot. The user is always looking for the best UPS manufacturer for the protection of their most expensive and important equipment. APC UPS System is one of the most selected UPS by the user. Detailed information about UPS System is given in the following article. If you want to read more about
This UPS is mainly used for hospital equipment, CNC machines, and IT firms.
Features and benefits :Protection :
The UPS system is the most important device to be installed to protect costly equipment from high voltage, Short circuits, and dangerous electrical threats. In India due to fast development every manufacturer, Institute, Industries, and hospital prefer to install an Online UPS system nowadays. We Powertune understands this need of the industry and propose the best UPS Brand to our customers always. Vertiv UPS system is One of the best UPS Systems in India and we are dealers of Hitachi UPS system in the thane, badlapur, Dombivli, Kalyan, Ambernath MIDC, Ambernath, Taloja MIDC, and Mhape MIDC areas.
Quanta SMF batteryis the most widely used battery in the UPS system in India.
Generally, the SMF battery is used for a wide range of applications with considered the most preferred battery for the UPS system.
Life of SMF battery
This battery is used for continuous application as the UPS system always works for 24 hours. based on practical data this battery gives life in between 3 5 years.
Battery specification
Download or view following data for quanta battery technical specification
Features :
industry-leading efficiency:
Liebert APS Specification
Unit Size, Type 10 Bay 16 Bay 12 Bay 16 Bay
No Transformer Transformer Based
Frame Rating, kVA/kW 5/4.5, 10/9,15/13.5 15/4.5, 10/9, 15/13.5, 20/185/ 4.5, 10/9, 15/13.5 15/ 4.5, 10/9,15/13.5,20/18
Input Parameter
Nominal Input Voltage Range 200/208/220/230/240; Single Phase
380/400/415: Three Phase
Input Voltage Range; Vac Input Voltage Range Depends on the 0/13 Loading
Power Factor Single Phase Input 0.99
Three Phase Input 0.95
Input Frequency Hz 50/60 Hz
Input Current Distortion THDi Less than 5%
Input Frequency Range 40/70 Hz Auto Sensing
Output Parameter
Output Voltage Vac 200/208/220/230/240 Vac
Voltage Regulation % ±3
Voltage Stability % ±7
Voltage Recovery Time, ms 560
Voltage Distortion % 5 3 on Linear Load
Single Phase Input 0.99
5 on Non-Linear Load 7 on Non-Linear Load
Output Frequency; Hz 50/60
104% Continuous
105%-130% For 1 Min
Overload Capability % 131%-150% For 10 Sec
151%-200% for 1 Sec
> 201% for 250 msec
Battery Module
Lead Acid Batteries Per String 12
Batteries Cells Per String, Pieces 72
Battery Capacity 36 W@15 Min rate to 1.67 V Per Cell@ 25 Degree Cel
Maximum Charging Current Power Module Internal Charger 1.8 Amps
Charger Module 10 Amps
Nominal Voltage, Vdc 144
General and Environmental Condition
Dimension WxDxH in mm 440x712x920
Operating Temp 0 to 40 Degree Celsius
Storage Temprature Without battery: -4 to 140 (-20 to 60) With battery: 5 to 104 (-15 to 40)
Relative Humidity 0-95% Non-Condensing
Altitude ft (m) 10000 (3000)
Range : 3 kvA 10 kVA
Voltage Rating: Suitable for Single-phase power supply systems.
Input Voltage Range: Typically designed to handle variations in input voltage, e.g., 140V-280V.
Output Voltage: Provides a stable and regulated output voltage within a narrow range, e.g., +/- 1-3% of the rated output voltage.
Capacity (in VA or kVA): Specifies the maximum load it can handle, such as 1 kVA, 2 kVA, 5 kVA, 10 Kva, etc.
Topology: Utilizes servo-controlled technology to regulate and stabilize the output voltage.
Display: Often equipped with an LED or digital display to show input and output voltage levels.
Protection Features: Includes features like over-voltage protection, under-voltage protection, short-circuit protection, and overload protection.
Efficiency: Typically designed to be highly efficient, reducing energy consumption.
Response Time: Offers rapid response to voltage fluctuations to ensure minimal disruption to connected equipment.
Operating Temperature: Specifies the range of temperatures in which it can operate effectively, e.g., 0C to 50C.
Cooling: have built-in cooling fans or passive cooling mechanisms for temperature control.
Luminous is known as the most famous inverter brand. Beautiful design and advanced features are the specialty of this brand. This inverter is sold in every corner of India. So when the topic of inverters comes up, the name of luminous automatically comes to mind. We Powertune are authorized Luminous inverter dealer in Thane, Badlapur, and Panvel
Luminous Power Technologies is known as the most powerful and reliable brand in India. They always try to provide innovative and adventurous products to customers. They have a wide product range in power backup and solar.
60000 channel partners have been developed, with the help of nearly 6000 thousand employees, along with seven manufacturing plants. Through this they have brought improvements in the lives of millions of customers.
. Sine wave Inverter best for a sensitive application like computers, laptop some adopters, medical instruments.
2. DSP processor intelligent working fast response ow power consumption.
3. LED display for the indication, it also shows battery remaining time in HRS
4. Comes with MCB protection for high voltage and short circuit
5. Inbuilt bypass switch can directly bypass load without disconnecting inverter system
6. Low harmonic distortion
7. Multiple batteries selecting switch compatible for various types of batteries.
Microtek High-Frequency Online UPS provides Uninterrupted Pure Power for Critical Applications such as Computer Network, Servers, Cyber Cafes, ATM Machines, CCTV Camera, etc.
Features :
Voltage Range Voltage Range | 110VAC ± 5 % ~ 300 VAC ± 5 % | |
Frequency Range | 40Hz ~ 70 Hz | |
Phase | Single-phase with ground | |
Power Factor | ≥ 0.99 @ full load | |
OUTPUT | ||
Output voltage | 200/208/220/230/240VAC | |
AC Voltage Regulation | ± 1% (Batt. Mode) | |
Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz | |
Current Crest Ratio | 3:1 | |
Harmonic Distortion | ≤ 2 % THD (Linear Load) ; 4 % THD (Non-linear Load) | |
Overload Capability | 105% ~ 110%: UPS shuts down after 10 minutes at battery mode or transfer to bypass when the utility is normal. 110% ~ 130%: UPS shuts down after 1 minute at battery mode or transfer to bypass when the utility is normal. >130%: UPS shuts down after 3 seconds at battery mode or transfer to bypass when the utility is normal. | |
Transfer Time | AC Mode to Batt. Mode | Zero |
Inverter to Bypass | < 4 ms (typical 2.5ms) | |
Waveform (Batt. Mode) | Pure Sinewave | |
EFFICIENCY | ||
Efficiency(AC Mode/Batt.Mode) | 88% / 83% | |
BATTERY | ||
Battery | Type & Numbers | SMF 12V / 9AH x 2 Nos. (IN-BUILT BATTERIES) |
Charge Current (Min.to Max. Range) | 1A | |
PHYSICAL | ||
Physical | Dimension (LxWx H) in mm | 282x145x220 |
Net Weight (Kgs.) | 9.8 Kgs. | |
ENVIRONMENT | ||
Operation Humidity | 20-95 % RH @ 0- 40°C (non-condensing) | |
Noise Level | Less than 50dBA @ 1 Meter (With fan speed control) | |
LED/LCD Indication | LCD Display Indications | |
MANAGEMENT | ||
Smart RS-232 or USB | Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux, Unix and MAC | |
Optional SNMP | Power management from SNMP manager and web browser | |
Warranty | One Year |
Microtek offers a Wide Range of Online UPS from 1KVA to 30 KVA dependent on Worlds Latest Technology to meet the unforgiving Environmental and most exceedingly terrible Power Conditions for Applications from Small Office necessity to Space Critical Missions with a wide assortment of Backup Range from 5 minutes to 10 hours to address the issues of each person.
Nominal Voltage | 208VAC/220VAC/230VAC | |
Frequency | 40 Hz~55Hz @ 50 Hz system | |
Acceptable Voltage Range | 165 ~285 VAC | |
OUTPUT | ||
Nominal Voltage | 208VAC/220VAC/230VAC | |
Voltage Regulation | ± 1 % | |
Frequency Range (Synchronized Range) (Mains Mode) | 45Hz~55Hz | |
Frequency Range (Battery Mode) | 50 Hz ± 0.1 Hz | |
Overload Specs (Mains Mode) | 110%- 120% : 30 MIN 120% – 130% : 5MIN >130% : 1 SEC | |
Overload Specs (Battery Mode) | 110% – 120% : 3 MIN 120% – 130% : 1 MIN > 130% : 1 SEC | |
Current Crest Ratio | 3 : 1 | |
Harmonic Distortion | <= 3 % THD (Linear Load) | |
<= 5% THD (Non-Linear Load) | ||
Transfer Time | AC to DC | Zero |
Inverter to Bypass | Zero (Turn OFF / Common Fault) | |
Bypass to Inverter | < 5ms (Turn ON/ System Recovery) | |
Waveform (Battery Mode) | Pure Sine wave | |
EFFICIENCY | ||
AC Mode | 87.00% | |
Battery Mode | 91% | |
EXTERNAL BATTERY | ||
Recommended Battery Type | DEFAULT: VRLA / SMF BATTERY TUBULAR BATTERY: OK (WITH CHARGER CUT-OFF VOLT ADJUSTABLE FROM LCD DISPLAY) | |
Numbers | 16 | |
Charging Current (Max.) | Default: 8A±10%; Max: 2A, 4A, 8A (Adjustable) | |
Charging Voltage (Default) | Boost Voltage : 224Vdc +-1%, 14.0V/Battery | |
Float Voltage : 217.6Vdc +- 1%, 13.6V/Battery | ||
INDICATORS | ||
LCD | Load Level, Battery Level, AC Mode, Battery Mode, Bypass Mode, and Fault Indicators | |
ALARM | ||
Battery Mode | Sounding every 4 seconds | |
Low Battery | Sounding every second | |
Overload | Sounding twice every second | |
Fault | Continuously sounding | |
PHYSICAL | ||
Dimension, DxWxH(mm) | 562 x 250 x 830 | |
Net Weight (kgs) | 62 | |
ENVIRONMENT | ||
Operating Temperature | 0~50ºC (Battery life cycle will shorten when temperature is above 25ºC) | |
Humidity | 0~95% (Non-Condensing) | |
Noise Level | Less than 50dB @ 1 Meter | |
MANAGEMENT | ||
Modbus RS-232/RS485 | Supports Windows® 2000/2003/XP/Vista/2008/7/8, Linux and MAC | |
Dry Contact | 5 Signals: AC Failure, Low Battery, UPS Alarm, Bypass and UPS Fault | |
Optional SNMP | Power Management from SNMP Manager and Web Browser | |
Warranty | Two Years |
Features :
MAINS INPUT | |
Voltage | 415 V +10% – 15% 3Ph 3W |
Frequency | 50 Hz ±10% |
DC BUS | |
DC Voltage Range | 305V to 482V |
Maximum DC Bus Ripple (without battery) | 2% RMS |
Max DC Bus Ripple (with battery) | 1% RMS |
OUTPUT | |
Nominal AC Voltage | 110/115/120/220/230/240 V |
Load Power Factor – Rated | 0.8 |
Load Power Factor – Range | 0.6 to Unity |
Voltage Regulation | |
Steady State | ±1% |
100% Step Load | ±5% typical |
Recovery Time to 98% | < 20 ms |
Over Load | |
110% | 3600 Seconds |
125% | 600 Seconds |
150% | 60 seconds |
Branch Fuse Clearing Ability | 30% of UPS rated current (fast acting semiconductor protection fuse)10% of UPS rated current (slow acting fuse)) |
Frequency | 50 Hz |
Bypass Synchronization Window | ±1% to 6% (Field Programmable) |
Internal Oscillator | ±0.1% |
Slew Rate | 1 Hz/Sec |
Total Harmonic Distortion | |
Linear Load | <2.5% |
Nonlinear Load (CF 3:1) | <5% |
OPERATING CONDITIONS | |
Ambient Temperature | 500C |
Altitude | 1000 Meter From MSL |
Humidity | 95% Non-Condensing |
Atmosphere | Non Corrosive, Dust Free, Freely Ventilated |
Audible Noise @ 1metre from Panel Front | 55 dBA to 75 dBA (depending on system rating and Configuration) |
ENCLOSURES | |
Construction | CRCA Steel Sheet |
Protection Class | |
Finish (Powder Coated) | RAL 7032 (Other Colours Optional) |
Ventilation | Forced Air (Internal Fans) |
Cable Entry | Bottom (Top Optional) |
Features :
1. Sinewave Inverter best for a sensitive application like computers, laptop some adopters, medical instruments.
2. 3 stage battery charging well for battery low maintenance and extended life.
3. Overload protection with auto reset function
4. Designed for Indian power condition top-selling model with proven performance.
5. Inbuilt bypass switch can directly bypass load without disconnecting inverter system
6. Eco mode work in low and high voltage conditions
7. Multiple batteries selecting switch compatible for various types of batteries.
8. low harmonic distortion creates noiseless operation.
Available in Digital and sinewave mode
UPS Merlyn Premium Series is a Smart UPS that accompanies many Smart highlights, Display status, Fault conditions and Battery Charging Voltage Selection for Longer Backup. It is one of the Largest selling UPS model in India which works from Standard Voltage range from 100 V 300 V and Narrow Voltage range from 180 V 260 V.
Features :
1. Sinewave Inverter best for a sensitive application like computers, laptop some adopters, medical instruments.
2. copper transformer long working life, less failure.
3. DSP processor intelligent working fast response low power consumption.
4. Comes with advanced ASIC technology to adjust charging parameters as per battery condition which increases the life of the battery.
5. LED / LCD both display for working indication.
6. Dual output socket of two types of load
7. Inbuilt bypass switch can directly bypass load without disconnecting inverter system
8. Low harmonic distortion low noise
9. Multiple batteries selecting switch compatible for various types of batteries.
Available in Digital and sinewave mode
The UPS-SW E+ is Super Energy Efficient Series The UPS-E+ Series accompanies the clever element of Battery Water Level Indication, which empowers opportune garnish of water in the Battery and guarantees Longer Battery Life. It is planned to utilize the Latest best-in-class Technology. It accompanies many Smart highlights, Display Status, Fault conditions, and Battery Voltage Selection Switch. The UPS works from a Standard Voltage range from 100 V 300 V and a Narrow Voltage range from 180 V 260 V.
Available in Digital and sinewave mode
UPS 247 Hybrid Series is the Premium UPS range which depends on Hybrid Technology which is a Perfect Combination of Digital and Sinewave Technologies which gives More Backup, More Battery Life, Handles More Load and it has Noiseless Performance.It accompanies an In-assembled Bypass highlight that empowers Bypassing of Power in the event of UPS disappointment.It is planned utilizing the Latest cutting edge Technology. It accompanies many Smart highlights, Display Status, Fault conditions, and Battery Voltage Selection Switch. The UPS works from a Standard Voltage range from 100 V 300 V and a Narrow Voltage range from 180 V 260 V.
Available in Digital and sinewave model
Its smart inverter comes with a display indication, battery failed option, battery charging voltage selection for longer backup. its largest selling UPS model of Microtek.
Features :
1. Squarewave technology
2. this inverter can charge a battery with a high charge even at low voltage condition best for rural area
3. Designed for Indian power condition top-selling model with proven performance.
5. Eco mode work in low and high voltage conditions also with UPS mode
7. Multiple batteries selecting switch compatible for various types of batteries.
Features :
1. Sine wave Inverter best for a sensitive application like computers, laptop some adopters, medical instruments.
2. DSP processor intelligent working fast response ow power consumption.
3. LED display for the indication, it also shows battery remaining time in HRS
4. Comes with MCB protection for high voltage and short circuit
5. Inbuilt bypass switch can directly bypass load without disconnecting inverter system
6. Low harmonic distortion
7. Multiple batteries selecting switch compatible for various types of batteries.
8. Blow alarm in case of short circuit
Features :
1. Sinewave Inverter best for a sensitive application like computers, laptop some adopters, medical instruments.
2. It has wide input voltage range work under 100 V to 290 V means work at even low voltage condition.
3. Charge battery with good charging current even at low voltage condition.
4. Soft touch button for On / Off switch and battery selection mode.
5. Comes with advanced ASIC technology adjust charging parameters as per battery condition which increases the life of the battery.
6. Protection for Overload , short circuit , Battery over charging, high temperature
7. Multiple batteries selecting switch compatible for various types of batteries.
A balanced three-phase inverter is used for applications that have the same current in all three phases. This is the most commonly used inverter for lifts and some lights.
Model | Balance Three Phase Inverters |
Power – KVA | 6 – 30 KVA |
Battery Voltage | 72 – 360 V |
Charging Current | 5 – 10 Amps |
AC Output Main | Above 160 V, same as input |
AC Output Inverter | 451 V + , 3 Phase- 4 wire, 50 Htz |
Display | LCD with LEDs for Mains, Inverter, Overload, Batt-low Charging |
Protections | Input under voltage, Overload, Short Circuit |
Battery Type | SMF, Automotive, Tubular |
Lighting Load | 10% of Capacity |
Field Programming | Battery Type, Charging current & Transfer delay |
This inverter is used for both industrial and residential. Because it can run both single-phase and three-phase equipment. unbalance means that even if one phase is loaded, the other phase will not affect. So this type of inverter is suggested where there is a water motor or lift and extra load
Model | Unbalance Three Phase Inverters |
Power – KVA | 8 – 100 KVA |
Battery Voltage | 144 – 360 V |
Charging Current | 5 – 10 Amps |
AC Output Main | Above 160 V, same as input |
AC Output Inverter | 451 V + , 3 Phase- 4 wire, 50 Htz |
Display | LCD with LEDs for Mains, Inverter, Overload, Batt-low Charging |
Protections | Input under voltage, Overload, Short Circuit |
Battery Type | SMF, Automotive, Tubular |
Lighting Load | 20% of Capacity |
Field Programming | Battery Type, Charging current & Transfer delay |
This Online UPSis extremelyuseful for offices, labs to run computersalongsideprinters and few lightsjust in caseofan influenceoutage foran extendedtime. The output of this Online UPS is regulated purewavewith low noise using high power IGBT modules.
This Online UPS can run Desktop computers, matrixprinters, laser printers, flex printing machines, and machinesutilized inlaboratories. With an LCD displayyoullread input, output voltagealsoas output and battery charging current.
Programming is providedto pickpower battery type, battery charging current, and inverter on warning.
Type | One Phase In One Phase Out Online UPS | |
Model | 3 KVA – 10 KVA | |
Input AC | Voltage range | 190 V – 270 V AC |
Frequency | 48 – 52 Hz | |
PF | 0.7 – 0.8 | |
Battery | Voltage | 72 V – 192V |
Charging Current | 4 – 10 Amps | |
Type | SMF / Tubular | |
Boost Cut-off Voltage | 13.8 V for SMF Battery / 14.4 V for Tubular Battery | |
Battery Low trip early warning | 10.8 Volts | |
Battery low trip | 10 V | |
Output | Waveform | Pure Sine wave |
THD | 3 % for linear load / 5 % for Non linear load | |
Crest Factor | 1:03 | |
Frequency | 50 Hz +/- 0.5 Hz | |
Voltage | 230 V AC +/- 2% | |
PF | 0.8 lagging | |
Galvanic Isolation | With Isolation Transformer | |
Inverter | Technology | Center Align HF PWM |
Switching Device | IGBT Modules | |
Galvanic Isolation | With Isolation Transformer | |
Charger | Technology | Phase Control |
Switching Device | Thyristor Modules | |
Protections | Input | MCB |
Output | Electronic trip for overload and short circuit | |
Battery reverse polarity | Fuse link / HRC fuse | |
Indications | LCD | Input, Output and Battery Voltage |
Output and Battery Charging Current | ||
LEDs | Mains OK, Inverter On, Overload, Charging On | |
Battery Low, System On & off | ||
Audio | Batter low trip early warning | |
Overload trip early warning | ||
Mains fail warning | ||
Bypass Switch | Manual | Electro mechanical |
Humidity |
A static voltage stabilizer, also known as an electronic voltage stabilizer, is an advanced electrical device designed to maintain a consistent and stable output voltage to protect sensitive electronic equipment and appliances from voltage fluctuations.
Unlike traditional servo-controlled stabilizers that use mechanical components, static stabilizers utilize solid-state electronic circuitry to regulate voltage. They offer rapid response times, high precision, and efficiency in maintaining a steady output voltage, making them ideal for applications where precision and speed are critical, such as data centers, medical equipment, and industrial processes.
Static voltage stabilizers are known for their reliability and ability to handle a wide range of input voltage variations, ensuring that connected equipment operates reliably and efficiently.