Our Products
Technical Specifications
Capacity | From 3 KVA to 1000 KVA 3Phase+N+E |
---|---|
Type of connection | Star Type Suitable for Unbalance Loads. |
Input voltage | 310 V to 480 V Line to Line (FR), 345 V to 480 V Line to Line (SR) &, 360 V to 460 V Line to Line (SSR)., Other ranges can be Quoted on request. |
Output voltage | 380 V/415 V Line to Line 220 V/240 V Line to Neutral Other Output optional |
Rate of correction | +1- 10 Volts L / N 35 Volts/Sec / 70 Volts/Sec (optional) |
Response time | Less Than 10 milliseconds |
Efficiency | > 97% |
Duty | Continuous |
Cooling | Naturally Air cooled upto 75 KVA 3 Phase and from 75 KVA onwards Oil Cooled. |
Protection features | Over/Under voltage & single phasing Protection., Trip Levels : +/- 10-12 Volts, Trip Reset : Manual, Trip Status : Individual LEDs for High and Low. |
Short circuit and overload protection | Is provided by an MCB at input. |
Single phasing prevention | Provided by means of Contactor. |
Surge suppressor | MOV are used |
Specifications
Capacity | 1 KVA TO 50 KVA |
---|---|
Input | Voltage : 170 - 270 V AC, 1 Phase Wide Rang : 90 - 350 V AC (optional) Frequency : 50Hz |
Output | Voltage : 230 + 1% V AC, 1 Phase Frequency : 50Hz Correction Speed : 35 Volts / Second Better than 95% Waveform Distortion : Nil Power Factor : Suitable for all power factor loads |
Protection | Fuse in AC incoming & AC outgoing Input under / over voltage Trip MCB for higher capacity |
Specifications
Capacity | 1 KVA TO 50 KVA |
---|---|
Input | Voltage : 170 - 270 V AC, 1 Phase Wide Rang : 90 - 350 V AC (optional) Frequency : 50Hz |
Output | Voltage : 230 + 1% V AC, 1 Phase Frequency : 50Hz Correction Speed : 35 Volts / Second Better than 95% Waveform Distortion : Nil Power Factor : Suitable for all power factor loads |
Protection | Fuse in AC incoming & AC outgoing Input under / over voltage Trip MCB for higher capacity |
Technical Specifications
Capacity | From 3 KVA upto 500 KVA 3Phase+N+E |
---|---|
Type Of Connection | Star type suitable for unbalance Loads. |
Input Voltage | 300 V to 480 V Line to Line & 345 V to 480 V Line to Line Other ranges can be Quotes on request. |
Output Voltage | 380 V/ 415 V Line to Line 220 V/240 V Line to Neutral Other Output optional |
Output Voltage Adj | +/- 10 Volts L / N |
Supply Frequency | As Input Frequency (50 Hz) |
Output Regulation | +/- 1% Nominal output from no load to full load & from Min. to Max. line variation. |
Rate Of Correction | 35 Volts/Sec. |
Response Time | Less than 10 milliseconds |
Servo Motor | High Torque AC syn motor controlled by a truly solid state electronic controller. |
Output Waveform | Same as Input. |
Effect Of P.f. | System not affected by load Power Factor. |
Facility For Manual Operation | Provided by means of an Auto-Manual selector switch and Raise /Lower push button switch inside the stabilizer. |
Over Load Capacity | Can withstand motor starting overload upto 200% |
Efficiency | Better than 96 % |
Duty | Continuous. |
Type Of Cabinet | Free Standing Unit. |
Cooling | Naturally Air cooled upto 75 KVA 3 phase and from 75 KVA onwards Oil Cooled. |
Effect Of Spikes | No Spikes or surges introduced by unit. |
Monitoring Voltmeter | Digital Voltmeter with keypad type selector switch to read Line to Line as well as Line to Neutral Voltage of Input and Output. |
On/off Switch | A Pair of keypad switches connected to Air brake Contractor will be provided for Stabilizer On/Off Operation. |
Protection Features | Over voltage / Under voltage and single phasing Protection. Trip Levels : +/- 10-12 Volts Trip Reset : Manual Trip Status : Individual LEDs for High and Low |
Short Circuit And Overload Protection | Is provided by an MCB at input |
Surge Suppressor | MOV are used. |
Single Phasing Prevention | Provided by means of contractor. |