UPS #924672

Our Complete range of products are Off Line UPS, Offline Power UPS and Online Power UPS.

Off Line UPS

  • Capacity 500 VA to 4 KVA
Voltage : 170 - 270V Single Phase, Frequency : 50Hz +- 1%, Rectifier : Automatic float cum boost charger, CVCC type, Voltage : 230 V + 3% with AVR, Voltage : 230 V + 3% with AVR, Wave from : Sine Wave (with AVR), Inverter Step approximate sine wave, 15 min. -10 Hrs. with External Battery
View Complete Details

Offline Power UPS

The company is ranked amidst the prominent Offline Power UPS Manufacturers, Exporters, and Suppliers from Nashik, India. The Offline Power UPS is made by using the finest components and materials in compliance with the set industry standards. Our Offline Power UPS is offered at very competitive prices. Applications
  • Medical Electronic Equipment
  • Telecommunication Equipment
  • Computer
  • Network Systems
  • Security & Emergency System
  • Process Control Equipment
Salient Features
  • RFI / EMI spike & Output of Inverter
  • Inverter Efficiency SMPS
  • Guaranteed uptime 95% minimum
  • User friendly UPS System
  • Advanced PWM / MOSFET / IGBT Technology
  • Prompt and Efficient service
  • Modular system and compact size
  • Caters to Genets / Electricity supply

Specifications

Capacity 500 VA to 4 KVA
Input Voltage : 170 - 270V Single Phase
Frequency : 50Hz +/- 1%
Rectifier : Automatic float cum boost charger, CVCC type.
Out Put Voltage : 230 V + 3% with AVR
Frequency : 50Hz + 2%
Wave from : Sine Wave (with AVR)
Inverter Step approximate sine wave
Back up Time Options 15 min. -10 Hrs. with External Battery
Recharge Time 6 to 8 hours for 90% charge
Indications Mains ON-(Glowing) i.e. UPS on mains
UPS ON ( Blinking)
- Every 5 sec with Buzzer - UPS on battery backup
- Every 5 sec with Buzzer - 75% of backup power utilized initiate save & quit operations
Fault (Glowing) - System trip due to Over Load / Battery Low / Short / No Load Cut Off
Control Method MOSFET based constant Voltage Current Limit
Transfer Time <4 Milliseconds
Environmental Temperature : 0 to 40oC
Humidity : Ambient 30 to 90%
Protections Built in AVR gives regulated output against fluctuation
Fuse for over load & short circuit protection
Noise & spikes gets eliminated by EMI / RFI filter
Battery Low, Over & Under Voltage Protection.
Indications Mains : On, Over voltage, Under Voltage, Failure
Battery : Charging, Low
Inverter : On, Output high, Output low, Output over load trip
Meters Voltmeter to read input & output
Controls Mains : MCB
Load : MCB ( Optional )
Inverter : DPDT
Static Bypass : ( Optional ) Adequately rated solid state switch which will transfer load from UPS to Mains within 10 Mesc. (synchronized ) 20 Msec. (unsynchronized) to avoid any damage to loads.

















View Complete Details

Online Power UPS

We are specialized in the manufacturing, exporting, and supplying of Online Power UPS in all over the world. The Online Power UPS is designed to give unlimited power supply even in longer power cuts. The Online Power UPS is used in various applications and is provided by us at competitive prices. Applications
  • Telecommunication Equipment
  • Medical Electronic Equipment
  • Computer
  • Security & Emergency System
  • Network Systems
  • Process Control Equipments
Salient Features
  • RFI / EMI spike & Output of Inverter
  • Inverter Efficiency SMPS
  • Guaranteed uptime 95% minimum
  • Advanced PWM / MOSFET / IGBT Technology
  • Caters to Genets / Electricity supply
  • User friendly UPS System
  • Modular system and compact size

Specifications

Capacity 500 VA to 50 KVA
Input Requirement Voltage : 230 V Single Phase + 19% - 15% or 415 V Three Phase +/- 15%
Frequency : 50Hz +/- 6%
Rectifier : Automatic float cum boost charger, CVCC type.
Out Put performance Voltage : 230 V Single Phase + 1% or 400 V Three +/- 1%
Frequency : 50Hz +/- 0.5Hz
Wave from : Sine Wave
Distortion THD less than 5% with no single harmonic greater than % on linear load,
Power Factor : 0.8 lagging to unity.
Inverter Side Inverter Efficiency :
On full load better than 85%
Control method : Sinusoidal PWM control
Circuit Method : True on Line PWM UPS Zero Transfer Time
Normal DC Voltage 48 V DC / 60 V DC / 120 V DC
144 V DC / 240 V DC / 300 V DC
Creast Factor : Better then 2.5
Transient Response For step load change from 25 to 100% output voltage will remain within 10% and recovers to 2% within 60 msecs.
Environmental Cooling : Forced air cooled.
Temperature : 0-50oC Ambient
Humidity : 95% RH non condensing
Acoustic Noise : Less than 60db at 2mts. from the cubicle.
Protections Input - Mains over voltage / under voltage
Output Output over voltage
Output under voltage
Output over current
Battery Battery over voltage
Battery low
Battery over current
Alarms Mains failure
Battery reverse polarity (Optional)
Battery low
Indications Mains : On, Over voltage, Under Voltage, Failure
Battery : Charging, Low
Inverter : On, Output high, Output low, Output over load trip
Meters Voltmeter to read input & output
Controls Mains : MCB
Load : MCB ( Optional )
Inverter : DPDT
Static Bypass : ( Optional ) Adequately rated solid state switch which will transfer load from UPS to Mains within 10 Mesc. (synchronized ) 20 Msec. (unsynchronized) to avoid any damage to loads.























View Complete Details