Post Buy Requirement

Our Products

  1. Relays 5 Products available
  2. Measuring Instruments & Equipment 5 Products available
  3. Battery Chargers 5 Products available
  4. Voltage Stabilizer 4 Products available
  5. Sensors 3 Products available
  6. Mosquito And Insect Repellent

    2 Products available
  7. Level Transmitters

    2 Products available
  8. Electrical & Electronic Goods Repair

    1 Products available
  9. Level Controllers

    1 Products available
  10. Others Products 23 Products available

Other Products / Services

Our Complete range of products are Ac Ampere, Intelligent Queue Management System, boost chargers, Automatic Source Changeover with Current Limiter and Solid State Call Indicator.

Ac Ampere

We are offering ac ampere. bmpm-i3pr2 features: ampere:r, y, bauto scroll hold4 digit displaydigital true rmsct ratio programmable specification: latest microcontroller based designspace saving compact designhigh speed 10 bit adcmoving average algorithmcrisp, bright, flicker-free led displaypre-calibrated metersrobust terminalssolid-state circuitry aux optionsa. 240vac(+-20%)b. 85-265 acdcaccuracyclass 0.2display3 4 digits0.56" height reddimensions96x48cutout 92x4496x96cutout 92x92mountingpanel door

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Control Transformers

We are offering control transformers. Control transformer is a transformer which supplies power to control and / or auxiliary equipment not intended for direct connection to the main source. Control transformers arespecifically used to provide control supply voltage for the control circuits of ac motor starters, i.e. Starter coils, timers, indicating lamps electronics protection relays etc. Control transformers for contractor applications have to energize the coil and maintain a contact for definite period of time. The initial energizing of the coil takes 5 to 40 mil. Seconds and requires 3 to 10 times the normal current. While calculating the va rating of the control transformer, this factor should be taken in to account. They are available for single phase and three phase inputs and are in the range from 15 va to 30 kva. constructioncontrol transformers are two winding transformers with both windings made of copper. Power house transformers are made of using high quality materials. Electrolytic grade super enameled wire with best insulations are used. Core material are crgo ei or strip cores. Experienced hands with best machines for windingensures best results with minimum size. Appropriate class of insulation materials are used. Transformers are impregnated in insulating varnish for long lasting performance. Input and out are terminated on bakelite board with proper size of terminals. information required while ordering:a) input supply-voltage, frequency and number of phases i.e. Single orthree phases. In case of three phase system type ofconnection- star / delta / vector group. b) out put voltage and current in of each secondary winding( ifmultiple out put windings are required). C) class of insulations:d) service conditions if other than standard service conditions. application specific transformers:we make transformers as per specific requirements and some ofstandard applications are* auto transformers for auto transformer starter, * high voltage transformers, * high current transformers for load testing, * potential transformers for metering andinstrumentation, *short circuit-proof transformers, *pulse transformers for power electronics

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Ups

We are offering ups. Economical reliable power sourcefor your pc power from the electricity supply company received for running of our domestic/commercial appliances is not always clean & stable. Read more it is polluted with so many unwanted elements. Rf interference, spikes, surges, fluctuating volts, etc. Are most dangerous for sophisticated equipment specially when systems are microprocessor based. According to a recent study, 48.5% of all instances of data loss are caused by power events. Power house offers line interactive ups series pus to provide complete power protection to your pcs. built in avr:power house series pus ups checks the mains power conditions and keeps output within safe range of 200 v to 240 v. Incase of low voltage up to 170 v, it increases and brings it up to normal safe value. In case of high voltage up to 270 v, it reduces and brings it down to safe value. In case of voltage above the avr range, it stops drawing from mains and switches on the inverter instantly. full time spike and surge protection:the spike buster consists of metal oxide varistor (mov), and high frequency filter. It has built in wide range rfi filter which insures complete cleaning and regulation of power. pwm controlled inverter:power house series pus ups has pulse width modulation technology for inverter to ensure regulated output during inverter operation. sleep mode:if the ups is switched on without load, the system checks it and switch off the oscillation and saves the battery from draining out. cold / slow start:starting load of the cpu and monitor is quite high. Normal ups can supply back-up only when the load is in on condition during mains. With this special circuitry out put voltage is built gradually thus facilitating the starting of pcs even during power off. over load /short circuit protection:the system is protected against over load and short circuit. sealed maintenance free (smf)batteries:power house series pus ups is backed by internationally accepted batteries. regulated charging:constant voltage, regulated current charger ensures extended life of battery. low battery cut-out:ensures longer battery life. low transfer time:fast sensing technology switches to battery operation in case of unhealthy main output. audio and visual indications:ac mains on, inverter on, fault conditions are indicated by leds. Inverter and fault conditions are also brought to the users notice by audio alarm. select the ideal modelmodelno. outputva typicalload batteryvoltppi-50 500 3f, 4t 1 x 12v. ppi-80 800 5f, 6t 2 x 12v. ppi-100 1000 7f, 6t 2 x 12v.

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Nurse Call Monitoring System

We are offering nurse call monitoring system. Bps offers digital call indicator and monitoring systems for hospitals and nursing homes. The system is designed updated and adopted to changing requirements of hospitals by our in house team having 15 years of experience. These are installed in many leading hospitals for years and are working with full satisfaction of each hospital. Very simple to install and maintain. system over view:each bed is provided with call station board consisting of bed pushconfirmation light and re-set push. The patient can make call formthe push switch. On receipt of call at the digital display board, confirmation light on the call station will be on. This ensures thatthere is no problem in wiring. The call received at display board canonly be re-set by the attending nurse from the re-set push providedat the bed side of patient (call station board). On attending the call, the confirmation light and the bed number at the monitor will beswitched off. If any call remains pending over a set period the particular number will be hi-lighted by flushing the digit & buzzer installed at the floor in-chargematron will be activated.this will help in avoiding any negligence in services. the system will comprise ofa) call station board, b) door indicator, c) digital display board, d) data logger carde) ups system call station boardis consisting of bed push confirmation light and re-set push. It is designed for standard modular box. door indicator:is consisting of cluster of leds mounted in specially designed cabinet. It has tangle round red acrylic cover. It may be installed out side the room. It starts flushing if any call in the room is pending. This helps the nurses moving by to attend immediately even before going to the nurses station. digital display board:the digital display board is call monitor console which is installed at the nurse center. All call received from any bed will be displayed by the respective bed number by 3 digit display. Select the display board as per total no of beds, toilets etc to be covered by one nurse station. It has soft buzzer which alerts the attendment on receipt of any new calls. call station boardis consisting of bed push confirmationlight and re-set push. It is designedfor standard modular box. data logger card:this is a add-on card to connect the display bard with any standard computer. With this add on card all events can be recorded. Call received from each bed is stamped with time of call and on attendance also it is stamped with time. Data thusgenerated helps the hospital management in taking appropriate decisions. The card is supported with specially developed softwar which is installed in the computer. ups system. The system has its own specially designed ups. It is consisting of a smf type 12 v 7 ah battery, automatic battery charger and allied accessories. unique advantages are: low voltage operation:the incoming mains is converted to 12 v.d.c. In the power supply section and patient is not put to danger even due to accidental snatching of wires. digital display of bed nos:with 2-3 digit bright led displays, bed number can be easily noticed from a distance. non attendance timer:each call received activates a built in timer and after a specified time, it activates a buzzer. battery backup:to facilitate making call even during power cut, the system is provided with a battery backup. re-set at patients bed:to re-set, the nurse or attendant has to press a button installed near the patient. This ensures attendance. cost effective solution:this system is very cost effective for installation and maintenance computer connectivity :with add-on card, the system can record each event and helps management in taking appropriate and logical decision. ordering information bps d20 d30 digital nurses call monitoring system. item description model no. quatity requried call station boardwith 3 " x 3" ms box, acralic cover, confirmation light, re-set push &bed push with 2 meter flexible wire bncm-pb1 each bed = 1 setwith 3 " x 3" ms box, modular cover, confirmation light, re-set push &bed push with 2 meter flexible wire bncm-pb2 (pb1 or pb2) door indicatorwith 8 nos red leds, red acrylic coversuitable for connecting up to 8 bedsin one room bncm-du-1 optional for each roomwith 3 colour leds, flash study offfunctions, acknowledge push, acraliccover suitable for connecting up to 4beds in one room bncm-du-2 digital display board with 2digit displaywith one no 2 digit display card, acralic cover, in ms box of 275 x 125 x 50 mm bncm-d2ca up to 6 bedswith two no. 2 digit display card, acralic cover, in ms box of 275 x 225 x 50 mm bncm-d2cb up to 12 bedswith three no.2 digit display card, acralic cover, in ms box of 300 x 325 x 50 mm bncm-d2cc up to 18 bedswith four no. 2 digit display card, acralic cover, in ms box of 300 x 460 x 50 mm bncm-d2cd up to 24 bedswith five no.2 digit display card, acralic cover, in ms box of 350 x 550 x 50 mm bncm-d2ce up to 30 bedswith six no.2 digit display card, acralic cover, in ms box of 350 x 6000 x 50 mm bncm-d2cf up to 36 bedsdigital display board with 3digitdisplay with oneno. 3 digit display card, acralic cover, in ms box of 300 x 125 x 50 mm bncm-d3ca up to 5 bedswith two no.3 digit display card, acralic cover, in ms box of 300 x 225 x 50 mm bncm-d3cb up to10 bedswith three no.3 digit display card, acralic cover, in ms box of 300 x 350 x 50 mm bncm-d3cc up to 15 bedswith four no.3 digit display card, acralic cover, in ms box of 300 x 450 x 50 mm bncm-d3cd up to 20 bedswith fiveno.3 digit display card, acralic cover, in ms box of 300 x 550 x 50 mm bncm-d3ce up to 25 bedswith six no. 3 digit display card, acralic cover, in ms box of 600 x 475 x 50 mm bncm-d3cf up to 30 bedsdata logger card computer interferance card with softwar fitted in enclosure bncm-dlc -1 up to 36 beds.ups sytem power supply with automatic battery charger, smf 12 v. 7 ah battery bncmups1 up to 36 beds=1 setwires frombed tocallstation 2 pair telephone wire as per distance from bedsto call station

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Intelligent Queue Management System

We are offering intelligent queue management system. Organized waiting area enhanced customer experience micro-controller based system effective solution for hospital opds stand alone embedded system helps in organizing waiting area reduced manpower requirement cost effective introduction iqms from bps is effective queuing solution for hospitals opds. It helps in handling large number of patients to be attended by a number of doctors in an opd. iqms is stand alone system. It does not required any computer. It have its own cup, memory chips and hardware. its communication system is based on muti-tape bus wiring - new technology for secure communication and reduced wires. All control and display units are designed in house for utmost reliability. the system in totality is designed keeping in mind its demand for reliability. read more functional description opds in the hospital have number of reception counter & number of chambers for doctors. Each chamber may be offered to different doctor at different time slots. patient willing to consult any doctor can book his her appointment at any reception counter. Attendant at reception counter inserts particular doctors chamber number & slot no. And commands for taken printout. each reception counter is wired to a master controller which stores all information and allots token no on every new booking. Master controller also up-dates each chamber of latest booking thus keeping doctors informed of waiting patients. doctors chamber have display cum key unit. For call in next patent, he presses one key and the next token no. Is displayed out-sed the chamber or at common waiting area having central display unit. components - functions and selection depending on no of chambers and daily flow of patient, no of reception counteris to be decided. Each counter will have one reception counter terminal and one printer. reception counter terminals (rct) are table mounting type. They have heavy duty key board with 12 keys (10 keys for numbers and two function keys), lcd display with 16 char. 2 line display, parallel port output suitable for dot-matrix thermal printer. terminal bq-rct3 is suitable for printing 3" width paper. Bq-rct2 is for printing 2" width paper. Printer with thermal printing or dot-matrix printing can be connected with these terminals. bq-rct2p is built in printer of 2" width thermal paper. format of the token can be customized incorporating the name address, telephone number and other details of the hospital, chamber no. And slot no. Of the doctor, date of booking, sl. No. Of booking, etc. advantage to hospitals reduced man power requirement& thus save on operating cost. effective time management for doctorsas instant display of issue of current token ensures smooth sequential flow of patient & thus transparent queuing easy ticket printing, flexible systemto customize as requitement creates a good environment & enhancesthe goodwill of the hospital. opdqsoftqueue management system softwarefor organized opd experience bps offers new software based queue management system- opdqsoft. It is a service toolkit for managing and continuously improving service delivery forlargenumber of patients at hospital opds. the automated system tracks each customer's movement from initial point of entry to the final point of service delivery; giving managers have the ability to identify key events such service time and wait time exceptions, peak traffic, queue lengths, best performing staff members and many more statistics. in addition, the opdqsoft reporting system and mis reports provide top management with a real time view of service performance as it happens from any business location. doctors chamber key board with lcd display each chamber will have terminal unit with key board & 16 char. 2 line lcd display. It is connected with the master controller. It displays last no. Of token issued, current slot no, & current token no. On issuing of any new token, for the chamber and slot no, the displayis up-dated. The key board has a master button for calling in the next number. there are three type of units available. Bqdwm is wall mountable with membranes switches. Bqdtm is table mountable with heavy duty keys. Bqdtm-1 has only one heavy push button forcalling in the next patient. this helps the doctor in managing his time effectively and ensuring all the booked patients areconsulted. central display unit if the waiting area for the patients are common to all chambers, central display units are to queue1be installed. This is connected with master controller and displays token no. Against eachchamber no. Bqmdb-4 displays information for 4 chambers, bqmdb-6 is for 6 chambers. Token no. With 3 digits are display. Bqmdbs-4 & 6 are display board with display of tokenno. And slot no. If there are more number of chambers, multiple of such boards can be cascaded. master controller master controller is the central processing unit. It receives request from all the reception counter. It generate token number for each chamber. It also instructs the printer of reception counter for printing the token with all the details. It also up dates doctor chamber display board on issue of any new number. the unit has power supply unit built in and it powers all the terminals and doctors chambers. For power supply, it is to be connected with mains socket. The unit is wall mounting type, small in size. token display board at doctors chambers token display board is provide out side the chamber or on the wall in the waiting room space. when the doctor intend to call in the next patient, the called number is displayed at this board. There are 3 digits of 7 segment bright led. bqlds2 has two side display- 3 digits for token no. And 1 digit for slat no. Bqlds1 has single side display- 3 digits for token no. And 1 digit for slat no. Bqld1 has one side display- 3 digits for token no. item description model no quantity required. Receiption counter terminal key board table mounting type heavy duty key board, with 12 keys 16 char. 2 line lcd display, parallel port output suitable for dot-matrix thermal printer of 3" width paper bq-rct3 each counter = 1 with printer bq-rcpd3 or bq-rctd3table mounting type heavy duty key board, with 12 keys16 char.2 line lcddisplay, parallel port output suitable for dot-matrixthermal printer of 2" width paper bq-rct2 each counter = 1 with printer bq-rcpd2 or bq-rcpt2table mounting type heavy duty key board, with12 keys16 char. 2 line lcddisplay, built in thermal printer for 2" width paper bq-rct2p each counter = 1printer dot-matrix printer for 3" width paper with serial port input, bq-rcpd3 with bq-rct3dot-matrix printer for 2" width paper with serial port input bq-rcpd2 with bq-rct2thermal printer for 3" width paper with serial port input bq-rcpt3 with bq-rct3thermal printer for 2" width paper with serial port input bq-rcpt2 with bq-rct2doctor's chamber in chamber display & key board wall mounting display board with 16 char. 2 line lcd display &12 no. Of membrane switches for calling in patient bq-dwm each chamber = 1table mountable display board with 16 char. 2 line lcd display &12 no. Of heavy duty switches for calling in patient bq-dtm each chamber = 1table mountable display board with 16 char. 2 line lcd display &1 no. Of heavy duty push for calling in patient bq-dtm-1 each chamber = 1waiting area token no. Display double side two inch height seven segment led display-3 digit token no. 1digit slot no. bq-lds2 each chamber = 1single side two inch height seven segment led display-3 digit token no. 1digit slot no. bq-lds1 each chamber = 1single side two inch height seven segment led display-3 digit token no. 1digit slot no. bq-ld1 each chamber = 1master controller micro-controller based central processing unit sutable for up to 6 reception counter & up to 32 doctors chambers bqmp2w4c each station = 1central display unit common waiting area (optional) wall mounting type central token no. Display unit for up to 4 chambers with 3 digit token no.display bq-mdb-4 up to 4 chamber = 1wall mounting type central token no. Display unit for up to 6 chambers with 3 digit token no.display bq-mdb-6 up to 6 chamber = 1wall mounting type central token no. Display unit for up to 4 chambers with 3 digit token no.& 1 digit slot no. Display bq-mdbs-4 up to 4 chamber = 1wall mounting type central token no. Display unit for up to 6 chambers with 3 digit token no.& 1 digit slot no. Display bq-mdbs-6 up to 6 chamber = 1junction box for connecting between reception counter master controller doctors chamber key board and token display board bqmst4-2 no. Of doctor's chambers + 1cables & accessories cat 6 wire of 1 2 meter with both side terminalscat 6 wire for connecting to each chamber with master controller as per site installation

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Electronic Hooter

Electronic hooter power house offers i.c. Based solid state electronics hooters suitable for control panel / control desk and other alarm annunciation boards with many unique features. read more solid state:hooters are ic based with professional gradecomponents and hence more reliable than theelectro mechanical hooters which are subject tofrequent coil burnout. low power consumption: power consumption is less then 25% ofconventional electro mechanical hooters. wide input supply voltage: power house electronic hooters are available for different input supply voltage e.g. 12 v. Dc to 220 v. Ac multiple sound (4 in one): series peh4 has provisions for 4 incoming signals(12 v or 24 v). Positive signals from different faultlocation may be fed to the hooter. Each faultcondition will trigger a different sound. Withaddition of this facility, the attendant can visualizecause of fault from a distance and may approach with particular tools/ spares for particular fault removal. Thus saving of time. continuous rating: power house solid state hooters are tested for continuous operation. easy flush mounting: mounting is suitable for standard meter cuttingsize. (92x92 mm) select the ideal hooter modelno. soundvariety selectionpeh-1peh-2peh-3peh-4 single sounddouble soundfour soundfour sound switch/terminalswitch/terminalswitch/terminalautomatic* standard supply voltage 12v dc, 24 v dc, 30v dc, 220v ac.

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Boost Chargers

We are offering boost chargers. Function: power house fcbc are designed to supply continuous power to the dc load and simultaneously charge the batteries connected. Input supply form 415 v. Ac 3 phase or 220 v. Ac 1 ph. Is converted to regulate dc. The charger has two independent systems. Normally the dc power is supplied to he load by the float charger. Read more it also supplies trickle current to the battery to keep it healthy. If the charging current under float mode exceeds a set level, boost charger is switched on. It supplies quick charging current to the battery. On battery reaching the set value, the boost charger is switched off. Application: float/ boost chargers are must in power substations, generating stations, telephone exchanges etc. For control / monitoring systems, tripping circuits and supplying dc power source. specifications: aux: : 415v. Ac ( 3 phase) / 240 v (1 phase) +/- 20 %/ +/- 10%, 50 hz. +/- 3 hz. Out put : 30 v, 48 v, 110 v and 220 v. Dc supply battery type : lead acid / smfindications and instruments: indications for 3 phase mains supply: float / boost section: ac volt meter with selector switch : dc volt meter with selector switch and battery volt: dc amps meter for load: dc amps meter for charging. Protection : mcb for mains incoming supply: mcb for out put load: over load cut out by electronics circuit: over voltage cut-out by electronics circuit: single phasing, under voltage for mainshousing and enclosure:: heavy duty sheet steel enclosurefinished with powder coated paint. Mounting : floor mountingoperation : auto/manualcontrol : cc/ cv close looprectifier : full wave half controlled bridgeoptional : fuse protection for each rectifier element: fuse failure relay: dc earth fault relay: alarm annunciation: dual float charger option: any other as per requirement. ordering inffbormation:mains supply voltageload voltage and currentbattery type, voltage and currentany optional equipments required

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Automatic Source Changeover With Current Limiter

Automatic source changeover with current limiter- a perfect solution for power sharing automatic load changeover relay (plcr) - is a high precession system for efficient distribution of generator power in multi-storied apartments, commercial complexes etc. series plcr-ds are designed to connect mains supply to load till mains is present. on mains failure and receiving generator power, it connects the load to dg supply. During dg operation, load drawn is monitored. If the load exceeds the allotted limit, it disrupts the supply and rechecks in intervals. On reducing the load and keeping it within the limit, load is connected to dg supply. for different applications, we have specific models. They are with load limiter, without load limiter, transfer of load from one phase to other phase and many additional functions. automation at no extra cost. generator power to all lighting points. no separate wiring is required. assured availability of allotted currentspace savingtamper proof & maintenance free. safeguards generatorfully solid stateled indication wide range of single & three phase mode.

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Solid State Call Indicator

We are offering solid state call indicator. Power house solid state call indicators for offices, chambers, hotels, houses etc. Where one or more attendant is supposed to attend number of executives customer, occupant etc. the system is designed to replace conventional electro-mechanical buzzers- switch indicator assembly. In these systems, whenever the call is made, a magnet coil pulls an arm which in turn activisms a switch assembly switching the indicator on. The magnet coil is designed for 1-2 sec. Operation. But if some one keeps the bell push pressed for a little long time, or the bell push remains shorted for a while, the coil gets burned out resulting in chances of fires. the power house solid state call indication system does not have any coil switches or relays. The signal received is sensed by a electronics circuitry. It activates a led to indicate the call station number. Constant or repeated call signals does not effect its internal working in any way. The call can be re-set by push in the indicator board. It has a soft tone buzzer which sounds for a pre-set time on receipt of each signal. Elegant in look these indicators match the sophistication and decor of the place. with no moving parts, magnet coil, these are maintenance free device and totally safe from fire hazards. installation and wiring is very simple. These can just replace the conventional call indicators without any major changes in wiring. special models with sealed maintenance free, batteries and with built in cccv chargers are available. Non-attendance timer digital display, single reset, remote reset, battery backup are also available. selection chartmodelno. no. Ofways approx size(mm)bezel cut out depth cina01cina04cina06cina08cina12 146812 96x96152x102230x102230x102242x152 80x80135x80135x80210x80210x150 5050505050

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Dc Multi Function

We are offering dc multi function. bpmd-2tsd voltage: v1, v2( 0-200 v dc) ampere(0-50a ext. Shunt) auto scroll hold 4 digit display digital true rms dc volt v1 dc volt v2 dc current(50a75mv shunt) features: latest microcontroller based designspace saving compact designhigh speed 10 bit adcmoving average algorithmcrisp, bright, flicker-free led displaypre-calibrated metersrobust terminalssolid-state circuitry specification:aux optionsa. 240vac (+-20%)b. 85-265 acdcaccuracyclass 0.2display3 4 digits0.56" height reddimensions96x48cutout 92x4496x96cutout 92x92mountingpanel door

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Ac Multi Function

We are offering ac multi function. bpmd-2tsa voltage: v1, v2(0-500 v ac) frequency(auto ranging) auto scroll hold 4 digit display digital true rms . Ac volt v1ac volt v2frequency features: latest microcontroller based designspace saving compact designhigh speed 10 bit adcmoving average algorithmcrisp, bright, flicker-free led displaypre-calibrated metersrobust terminalssolid-state circuitry specification:aux optionsa. 240vac (+-20%)b. 85-265 acdcaccuracyclass 0.2display3 4 digits0.56" height reddimensions96x48cutout 92x4496x96cutout 92x92mountingpanel door

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Dc Volt

We are offering Dc Volt. BDPM-VD2 3 Digit DC Voltmeter Features: Crisp, Bright, Flicker-free LED DisplayPre-calibrated metersLatest LSI IC technologyAuto Polarity and Auto ZeroCompact DesignRobust TerminalsSolid-state circuitryInternational Styling Specification: Aux OptionsA. 240VAC(+-20%)B. 85-265 ACDCAccuracyClass 0.5Display3 4 Digits0.56" Height REDDimensions96x48Cutout 92x4496x96Cutout 92x92MountingPanel Door

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Dc Amps

We are offering dc ampere meter. bdpm-ad2 3 digit dc ampere meter features: crisp, bright, flicker-free led displaypre-calibrated meterslatest lsi ic technologyauto polarity and auto zerocompact designrobust terminalssolid-state circuitryinternational styling specification: aux optionsa. 240vac(+-20%)b. 85-265 acdcaccuracyclass 0.5display3 4 digits0.56" height reddimensions96x48cutout 92x4496x96cutout 92x92mountingpanel door

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

SMPS

We are offering smps. Features:universal input range (85 265 vac, 50 hz)undervoltage and overvoltage protectionover load and short circuit protection low working temperature. input surge current limiting. ultra compact power supply. industrial grade components. low ripple & noise. soft start. high efficiency. on board emi/rmi filterover temp shutdownreliable and cost efficient. screw/ jack type connectersadjustable output voltage +/- 10% (sel. Models) specification:ac input : 85 264 v ac (47-63 hz) / dcdc output : please ref. Output specificationripple/noise : less than 1% pk-pk (bw 20 mhz)over voltage : set at 125% (+/-5%) of output voltagewithstand voltage : i/p-o/p : 3kv. Line regulation : +/- 1% on full loadload regulation : on main of +/- 1%working temperature : 1060 deg.c. Efficiency : >75% typical @ full rated loadsafety standard : to comply with ul 1950, iec 950fusing : through mor/ glass fuse. Protection : overload, over voltage & shortcircuit protected. select the right supply voltage(volt) amperes(amp.) 5 1/2/3/5/1012 1/2/3/5/1024 1/2/3/548 1/2 multiple output models available on requestcustom made supplies made for your requirementspecial models available for battery chargingoptional paralleling facility with n+1 diode select the right supply:

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Microprocessor Based Solid State Alarm Annunciator

We offer microprocessor based solid statealarm annunciator. Function:annunciator is helpful to understand instantly from one place, the abnormal conditions of different process parameters i.e.temp. Pressure, tripping of any monitor relays. The system design is based on cmos technology providinghighest degree of reliability, ruggedness, flexibility, economyand aesthetics. it has built in push switches for test, accept, reset andsmall pizzo buzzer.test push is for instant versification of entiresystem.this triggers signal of all fault conditions resulting inflashing of all windows and actuation of hooter.external pushswitches and hooter can be connected through back connection. application:audio visual alarm for * process industry, * electrical panels, * d.g. Set panels, * chemical plants, * power plant. Etc, advanced microcontroller designoptically isolated inputsaux. 85-265 v acdc also available *long life super brightleds for each windows*low power consumption*compact size*standard din cut out*built in push switches*provision for externalpush switches*interlocking potentialfree relaymodel no. pand2-4 pand2-6 pand2-8 pand1-12 pand1-16 pand2-24number of channels 4 6 8 12 16 24 fault input potential free no contact can also be designed for voltage (potential) inputwindow size(h x w) 28 x 57mm 17 x 55mm 17 x 55mm 40 x 40mm 40 x 40mm 40 x 40mmlamps 4 nos. Of super bright red led slegends photo negative changeable from frontflash rate 40 flash per minpush switches test , accept, re-set push on front panel externalremote pushes can be connected from back terminalrelay out put rl1for hooter (potential free) 5 amp, rl 2 for interlocking (potential free) 5 ampaux supply 85 v 110 v 220 v 265 v ac, 12 v, 24 v, 48 v dc (pre-specified)operating temperature up to 50 degree c. (ambient)housing abs moulded sheet steel enclosuremounting standard din size panel enclosure panel cut out(h x w) 185 x 92mm 185 x 92mm 185 x 92mm 170 x 220mm 255 x 345mm 345 x 255mmoverall size(h x w x d) 190 x 94 x 150mm 190 x 94 x 150mm 190 x 94 x 150mm 183 x 235 x 180mm 280 x 370 x 70mm 370 x 280 x 70mminbuildpush button yes yes no no yes yesinbuildhooter no no no no yes no

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Emergency Light

We are offering emergency light. Function: emergency lights are designed to provide lights onpower interruption. These lights have built in * battery (smf type), * battery charger * change over circuitry and* inverter. Till the mains is on, the charger stores the energy in the battery. In the event of power failure, the stored energy is used to light up the tubes. application:to avoid accident and unwanted situations, these are must for! industries, ! hotels, ! railways stations, ! air ports theaters and! all public places. specifications: parameters edt-051 edt-054 eld-2 eld-3input volt 170v.-270 v. frequency 50hzbattery volt 6 12 6 12ah 4 7 10 7type smfnos. 1 2 1 2illumination tube / lamp 20 w. 40w 36w 20wnos. 1 1 1 2chargertype automatic cc/cv current max. 1 amp operation automatic on mains failure back-up time 2 hours ( approx.)protections mains glass fuse battery over chargingindications-led mainscharginghousing sheet steel powder coatedmounting wall mounting

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Water Level Controller,water Level Controller

We are offering water level controller. wl21p a low cost, reliable, ic based water level controllers. It keep constant watch on the water level and switch on or off the pump motors subject to availability of water at the reservoir and requirement level set at the upper tank. working principle: series pwl21p is designed to operate with electrode type to sense the water level. Stainless steel sensors with connector box are installed both at over head tank and reservoir. no dry run of motor and no over flow of water: sensors installed in the reservoir senses the availability of water in it. The sensors at the overhead tank is preset with a level at which the pump is to operate and switch off on reaching upper level. The pump is switched on only if the water is available at the reservoir. The system ensures no over flow from the overhead tank and no motor burn out due to dry running . auto/manual/off selection: the controller has auto/ manual/ off selection switch on the front panel. Under manual mode pump can be switch on manually, if the switch is in center- off position, motor remains off. This option may be required in emergencies and for cleaning up the electrodes or water tanks. protections: the controllers has built in protections for a) over/ under voltage protectionthe controller protects the motor from running at low/ high voltage thus saves the motor burnout. b) over load protection:electronics based over load circuit switches off the motor if load drawn exceeds the pre-set value and thus protects the pump motor from damages. indications:the controller is provided with following led indications: a) undervoltage b) overvoltage c) overload d) pumpon e) lowtank f) fulltank g) mainson housing:the controllers are housed in sheet steel enclosures finished with power coating paints. They are suitable for wall mounting. direct operation:up to 2 h.p. 1 ph. Phaseon demand, higher rating can be supplied.

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Fly Killer

We are offering fly killer. Flying insects killerthe battle with insects: flying insects are dangerous to mankind as they cause discomfort at working place become medium for spreading dangerous deseases, suck human blood and inject deadly germs in the body. Food beverages, sweets and eating items are poisioned and become unfit for human being. Safe & economical: pesticides and chemicalsare sprayed to control them but these methods have very temporary effects and also causes many new problems by polluting the atmosphere. It has been ecologically proved that ultra violet radiations has magnetic attraction to various flying insects like flies, mosquitoes, home flies, moths, etc. anu flykill is based on these discoveries and employs one/two special variety of ultra violet tube lights to attract these flying insects. A high voltage electrically charged guard is placed near by, which kills them instantly. Tray at the bottom is used to collect them. By these arrangements, flying insects do not drop here and there like in case of chemical sprays. Running cost of anu flykill is very negligible as no consumables are required except electricity. features different models for varying needs:- modelno. mounting tube areacoveredsq. Ft. No. lengthin inches wattspertubeakc21208akc21815akc22420 table/cornerwall/cellingwall/celling 222 121824 81520 300-500800-12001500-1800

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Auto Light Controller

We are offering auto light controller. function detects availability of natural lights and switches on/ off lights automatically. Optional built in off delay timer is also available. applicationauto light operation for external lighting. specification: aux. Supply : 240 v. Ac. selection chart model no. load in va sensor off delay timer switching dev. housingpalc 03 300 in built no relay surfacepalc10 1000 remote no relay surfacepalc25 2500 remote no relay surfacepalc10t 1000 remote yes relay surfacepalc25t 2500 remote yes relay surfacepalc5r 750 remote no relay railpalc5tr 750 remote yes relay railpalc5f 750 remote no relay flashpalc5tf 750 remote yes relay flashpalc10ss 1000 remote no solid state surfacepalc25ss 2500 remote no solid state surfaceplf10ss 1000 no sensor no solid state surfaceplf25ss 2500 no sensor no solid state surfaceplfr10 1000 no sensor no relay surfaceplfr25 2500 no sensor no relay surface sensors : ldrtimer : optional built inindication led : aux. Supply, : out put onmounting : panel / wall/ out door/enclosure : abs molded/ sheet steelout put : 3 a to 25 a. auto/ manual : toggle switch

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Magnetic Float Sensor

We are offering magnetic float sensor. Function:magnetic float switches / level sensor sare used to detect thesenor shave seale dreed switches in a stem with a permanentmagnet installed in the float.as float rises or falls, switch isactivated/deactivated. power house float sensor uses unique magnetic push at the floating magnet to respond fast to anychange of liquid level. features:unique magnetic liftsuitable for water/oil or fuel sensingeasy installationcan be installed directly on pipe specifications:level measurement type :point level switching capacity :10 w/vaswitching current :0.5 amp.max. Switching voltage :25 v dc max. Material :engineeringplastic cable :2coretemperature :-25 to 75c

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Micro Controller Based Nurse Call Monitoring System

We are offering micro controller based nurse call monitoring system. How to monitor and fix-up responsibility. to ensure the practice is followed, the system must be reliable and must have built in mechanism to point out delay in action. nurses call monitoring system series 640 informs the nursing staff the sequence of call received thus minimizing any over due call. The call register maintains sequence in which call from different bed are received. the first call pending is displayed with big 2 7 segment display. 4 other calls are displayed in the sequence of receipt. If more then 5 calls are pending, the same can be scrolled down. Any call attended is automatically erased and display is replaced with the next call pending. if any call is pending beyond set time, the number starts blinking. It also activates a buzzer to draw attention of the nursing staff. If call remains pending even beyond 2nd limit, rate of blinking is intensified to bring notice of problem. micro-controller based systemserial display of calls received-1st call displayed with 2" height leddisplay, next 4 calls in sequence on sidecolumn, further pending calls- onscrolling 3 digit 7 segment displays. soft tone buzzer- alerts receipt of new call elegant look compact and flexible- table- wall mountable. built in non attendance timer- pending calls flash- long pending calls flash at higher rates modular bed side console- easy installation in std. Modular cabinet status indicators and buttons- ready, call & wait led indicationon board, with call & reset switch elegant patient remote low voltage operation- the system works on 12 v. D.c hence patient is not put to danger even due toaccidental snatching of wires. reset at patient bed- re-set button installed near the patient. compact and flexible- the system requires very low space andis flexible to accommodates up to 64 beds. next generation system fromindustry leader leaders in nurses call monitoring system in india bps team is presenting the latest technical innovation in the line. The system is designed by our in house team to suit indian conditions. system over view series 640 consists of mainly the following sub-systems: a) call station boardb) patient remote hand setc) door indicatord) toilet pull corde) master controller hubf) nurses monitor console call station board each bed is provided with call station board. This is housed in standard console. It has push switches to call and re-set the call. led indications for ready(green), call(red), and wait(yellow) are provided. Ready led indicates that the system is ok and call can be made. If there is any problem with wiring, it will not glow. This is built in system to give instant check of any system or wiring fault. led marked call lights up when the call is made. Once the call is made and it is registered with the controller hub, led marked wait glows indicating call has reached nurse station. patient remote hand setfrom call station, remote patient hand set is provided so that the patient can make call form his bed. Remote hand set has push to make call. Led indication for ready, call and wait are provided. door indicatordoor indicator is installed out side the room to indicate call pending in the room. This facilitates nursing staff to attend on way to nurse station. One door indicator can announce pending call forup to 8 beds in the same room. Door indicators are available with many features like color leds, hold switch etc. toilet pull cord:toilet pull cord with indicator & rope. Standard length of rope is 1.5m. This pull cord is installed in side the toilet. Patient can use the pull cord in toilet. master controller hub:controller hub is central unit installed near nurse monitor console. It is consisting of one micro-processor central controller card, one connector card for up to 16 beds smps. Wires from all beds are terminated on connector pcb. It receives information fromeach bed and signals the console to display the information. nurses monitor consolethe call monitor console will be installed at the nurse center. Call received from any bed will be displayed by the respective bed number by 3 digit 7 segment led display. It can be mounted on wall or table stand. The first call pending is displayed with big 2 7 segment display. Other 4 calls are displayed in the sequence of receipt. If more then 5 calls are pending, the same can be scrolled down. Any call attended is automatically erased and display is replaced with the next call pending. connections:two pair telephone cable will be required to connect each bed to display board. Telephone type socket is punched to wires from each bed. Mains supply of 230 v ac is required at controller hub. low voltage operation:the incoming mains is converted to 12 v. D.c. In the power supply section and patient is not put to danger even due to accidental snatching of wires. re-set at patients bed:to re-set, the nurse or attendant has to press a button installed near the patient. This ensures attendance. compact and flexible:the system requires very low space and is flexible to add on as the number of beds increases. Marking on he indication board can be custom designed for easy location and is editable. our expertisenurses call monitoring systems and queue management systems by team bps is installed in all the leading hospitals in eastern india. With over 15 years of feed back from actual working condition in hospitals, continuous improvement in design, innovation of technology we are presenting series 640-the most advanced nurses call monitoring system. The system is designed with utmost reliability, dependability, safety, and flexibility in mind. ordering informationitem description model no. quantity reburiedcall station board with membrane push switches for call and re-set buttons& leds for ready, call and wait, connector for console connectionand connector for patient remote hand set bncm-pb640a each bed = 1 setpatientremote handset with flexible wire of 2 meters, telephone type jack connector, switch for call and indication for ready, call & wait bncm-pb640r each bed = 1 setdoor indicator with 8 nos red leds, red acrylic cover for connecting up to 8 bedsin one room bncm-du-1 optionalwith 3 colour leds, flash study off functions, acknowledge push, acrylic cover suitable for connecting up to 4 beds in one room bncm-du-2 for each roomtoilet pullcord toilet pull cord with indicatorrope length standard 1.5 m bncm-tpc1 for each toiletmaster controllerhub type-1 with one micro-processor central controller card, one connector cardfor up to 16 beds, power supplies (smps) housed in hinged cabinet bncm-mch640a up to 16 bedsmaster controllerhub type-2 with one micro-processor central controller card, two connector cardfor up to 32 beds power supplies (smps) housed in hinged cabinet bncm-mch640b up to 32 bedsmaster controllerhub type-3 with one micro-processor central controller card, three connector cardfor up to 48 beds power supplies (smps) housed in hinged cabinet bncm-mch640c up to 48 bedsmaster controllerhub type-4 with one micro-processor central controller card, four connector cardfor up to 64 beds power supplies (smps) housed in hinged cabinet bncm-mch640d up to 64 bedsnurse monitorconsole with one 2" height & 4 nos 34" height led displaysuitable for wall mounting and with table stand bncm-nch640a up to 64 bedsdata logger card computer interference card with softwarefitted in enclosure bncm-dlc-2 optionalup to 64 bedswires from bedto call station 2 pair telephone wire as per distance from beds tocall station

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Ac Volt

We are offering ac volt. bmpm-v3pr2 features: voltage:r, y, bauto scroll hold4 digit displaydigital true rms specification: latest microcontroller based designspace saving compact designhigh speed 10 bit adcmoving average algorithmcrisp, bright, flicker-free led displaypre-calibrated metersrobust terminalssolid-state circuitry aux optionsa. 240vac(+-20%)b. 85-265 acdcaccuracyclass 0.2display3 4 digits0.56" height reddimensions96x48cutout 92x4496x96cutout 92x92mountingpanel door

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Dc Drive

We are offering dc drive. 1/4 - 2.0 hp @ 230 vac 1-ph., 50 hz: 180v armature 1/8 - 1.0 hp @ 115 vac 1-ph., 50 hz: 90v armaturefor the operation of permanent magnet dc motors only. function:series pdcd dc drives are new generation of dc drives for 1/8 - 2 hp motors and for use on line supply voltages from 230 or 115 v ac. series pdcd dc drives are designed using the latest cmos technology which helps to reduce maintenance, increase product reliability and enables extremely rapid commissioning. features:easy to handle, install easy to design into machine equipmentfused ac input connectionscontrol speed from:- 10k ohm potentiometer included with drive (front panel)- external 10k ohm potentiometer- external input (0-10 v dc)- external input (4-20ma dc)speed regulation- 1% speed regulation armature voltage feedbackflush mounted operator devices:- power on/power off switch- power on indicator- speed potentiometeron-board leds for diagnostics:- power-on indication- fault indicationterminal block for easy usemonitoring functions:- overload- minimum field currentoptional setting for:- minimum speed : 0-35%- maximum speed: 75-100%- acceleration/deceleration: 0.5-17 sec. - armature over current trip application:dc drives are widely used for control of dc motors in various industries like:packaging equipment, conveyors, metering pumps, take-ups, mixers, material handling machines, exercise equipment, feeders, printing presses tapping machines, robotics and many more. specifications: aux. Supply : 240 v (ac) / 110 v (ac)output : 0 - 180 (v dc)/ 0 -90 (v dc)indication : led (power-on, fault )mounting : flushenclosure : abs molded dimensions : 96x192x150 (cutout 92 x 92reset : by system on-offswitch

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

List of Other Products by power Services from Kolkata, West Bengal.
Post Buy Requirement

Our Products

  1. Relays 5 Products available
  2. Measuring Instruments & Equipment 5 Products available
  3. Battery Chargers 5 Products available
  4. Voltage Stabilizer 4 Products available
  5. Sensors 3 Products available
  6. Mosquito And Insect Repellent

    2 Products available
  7. Level Transmitters

    2 Products available
  8. Telecommunication Equipment & System

    1 Products available
  9. Instrumentation & Control Equipment

    1 Products available
  10. Others Products 24 Products available

Our Products

We offer a complete product range of Ac Ampere, Intelligent Queue Management System, boost chargers, Automatic Source Changeover with Current Limiter and Solid State Call Indicator

Ac Ampere

We are offering ac ampere. bmpm-i3pr2 features: ampere:r, y, bauto scroll hold4 digit displaydigital true rmsct ratio programmable specification: latest microcontroller based designspace saving compact designhigh speed 10 bit adcmoving average algorithmcrisp, bright, flicker-free led displaypre-calibrated metersrobust terminalssolid-state circuitry aux optionsa. 240vac(+-20%)b. 85-265 acdcaccuracyclass 0.2display3 4 digits0.56" height reddimensions96x48cutout 92x4496x96cutout 92x92mountingpanel door

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Control Transformers

We are offering control transformers. Control transformer is a transformer which supplies power to control and / or auxiliary equipment not intended for direct connection to the main source. Control transformers arespecifically used to provide control supply voltage for the control circuits of ac motor starters, i.e. Starter coils, timers, indicating lamps electronics protection relays etc. Control transformers for contractor applications have to energize the coil and maintain a contact for definite period of time. The initial energizing of the coil takes 5 to 40 mil. Seconds and requires 3 to 10 times the normal current. While calculating the va rating of the control transformer, this factor should be taken in to account. They are available for single phase and three phase inputs and are in the range from 15 va to 30 kva. constructioncontrol transformers are two winding transformers with both windings made of copper. Power house transformers are made of using high quality materials. Electrolytic grade super enameled wire with best insulations are used. Core material are crgo ei or strip cores. Experienced hands with best machines for windingensures best results with minimum size. Appropriate class of insulation materials are used. Transformers are impregnated in insulating varnish for long lasting performance. Input and out are terminated on bakelite board with proper size of terminals. information required while ordering:a) input supply-voltage, frequency and number of phases i.e. Single orthree phases. In case of three phase system type ofconnection- star / delta / vector group. b) out put voltage and current in of each secondary winding( ifmultiple out put windings are required). C) class of insulations:d) service conditions if other than standard service conditions. application specific transformers:we make transformers as per specific requirements and some ofstandard applications are* auto transformers for auto transformer starter, * high voltage transformers, * high current transformers for load testing, * potential transformers for metering andinstrumentation, *short circuit-proof transformers, *pulse transformers for power electronics

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Ups

We are offering ups. Economical reliable power sourcefor your pc power from the electricity supply company received for running of our domestic/commercial appliances is not always clean & stable. Read more it is polluted with so many unwanted elements. Rf interference, spikes, surges, fluctuating volts, etc. Are most dangerous for sophisticated equipment specially when systems are microprocessor based. According to a recent study, 48.5% of all instances of data loss are caused by power events. Power house offers line interactive ups series pus to provide complete power protection to your pcs. built in avr:power house series pus ups checks the mains power conditions and keeps output within safe range of 200 v to 240 v. Incase of low voltage up to 170 v, it increases and brings it up to normal safe value. In case of high voltage up to 270 v, it reduces and brings it down to safe value. In case of voltage above the avr range, it stops drawing from mains and switches on the inverter instantly. full time spike and surge protection:the spike buster consists of metal oxide varistor (mov), and high frequency filter. It has built in wide range rfi filter which insures complete cleaning and regulation of power. pwm controlled inverter:power house series pus ups has pulse width modulation technology for inverter to ensure regulated output during inverter operation. sleep mode:if the ups is switched on without load, the system checks it and switch off the oscillation and saves the battery from draining out. cold / slow start:starting load of the cpu and monitor is quite high. Normal ups can supply back-up only when the load is in on condition during mains. With this special circuitry out put voltage is built gradually thus facilitating the starting of pcs even during power off. over load /short circuit protection:the system is protected against over load and short circuit. sealed maintenance free (smf)batteries:power house series pus ups is backed by internationally accepted batteries. regulated charging:constant voltage, regulated current charger ensures extended life of battery. low battery cut-out:ensures longer battery life. low transfer time:fast sensing technology switches to battery operation in case of unhealthy main output. audio and visual indications:ac mains on, inverter on, fault conditions are indicated by leds. Inverter and fault conditions are also brought to the users notice by audio alarm. select the ideal modelmodelno. outputva typicalload batteryvoltppi-50 500 3f, 4t 1 x 12v. ppi-80 800 5f, 6t 2 x 12v. ppi-100 1000 7f, 6t 2 x 12v.

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Nurse Call Monitoring System

We are offering nurse call monitoring system. Bps offers digital call indicator and monitoring systems for hospitals and nursing homes. The system is designed updated and adopted to changing requirements of hospitals by our in house team having 15 years of experience. These are installed in many leading hospitals for years and are working with full satisfaction of each hospital. Very simple to install and maintain. system over view:each bed is provided with call station board consisting of bed pushconfirmation light and re-set push. The patient can make call formthe push switch. On receipt of call at the digital display board, confirmation light on the call station will be on. This ensures thatthere is no problem in wiring. The call received at display board canonly be re-set by the attending nurse from the re-set push providedat the bed side of patient (call station board). On attending the call, the confirmation light and the bed number at the monitor will beswitched off. If any call remains pending over a set period the particular number will be hi-lighted by flushing the digit & buzzer installed at the floor in-chargematron will be activated.this will help in avoiding any negligence in services. the system will comprise ofa) call station board, b) door indicator, c) digital display board, d) data logger carde) ups system call station boardis consisting of bed push confirmation light and re-set push. It is designed for standard modular box. door indicator:is consisting of cluster of leds mounted in specially designed cabinet. It has tangle round red acrylic cover. It may be installed out side the room. It starts flushing if any call in the room is pending. This helps the nurses moving by to attend immediately even before going to the nurses station. digital display board:the digital display board is call monitor console which is installed at the nurse center. All call received from any bed will be displayed by the respective bed number by 3 digit display. Select the display board as per total no of beds, toilets etc to be covered by one nurse station. It has soft buzzer which alerts the attendment on receipt of any new calls. call station boardis consisting of bed push confirmationlight and re-set push. It is designedfor standard modular box. data logger card:this is a add-on card to connect the display bard with any standard computer. With this add on card all events can be recorded. Call received from each bed is stamped with time of call and on attendance also it is stamped with time. Data thusgenerated helps the hospital management in taking appropriate decisions. The card is supported with specially developed softwar which is installed in the computer. ups system. The system has its own specially designed ups. It is consisting of a smf type 12 v 7 ah battery, automatic battery charger and allied accessories. unique advantages are: low voltage operation:the incoming mains is converted to 12 v.d.c. In the power supply section and patient is not put to danger even due to accidental snatching of wires. digital display of bed nos:with 2-3 digit bright led displays, bed number can be easily noticed from a distance. non attendance timer:each call received activates a built in timer and after a specified time, it activates a buzzer. battery backup:to facilitate making call even during power cut, the system is provided with a battery backup. re-set at patients bed:to re-set, the nurse or attendant has to press a button installed near the patient. This ensures attendance. cost effective solution:this system is very cost effective for installation and maintenance computer connectivity :with add-on card, the system can record each event and helps management in taking appropriate and logical decision. ordering information bps d20 d30 digital nurses call monitoring system. item description model no. quatity requried call station boardwith 3 " x 3" ms box, acralic cover, confirmation light, re-set push &bed push with 2 meter flexible wire bncm-pb1 each bed = 1 setwith 3 " x 3" ms box, modular cover, confirmation light, re-set push &bed push with 2 meter flexible wire bncm-pb2 (pb1 or pb2) door indicatorwith 8 nos red leds, red acrylic coversuitable for connecting up to 8 bedsin one room bncm-du-1 optional for each roomwith 3 colour leds, flash study offfunctions, acknowledge push, acraliccover suitable for connecting up to 4beds in one room bncm-du-2 digital display board with 2digit displaywith one no 2 digit display card, acralic cover, in ms box of 275 x 125 x 50 mm bncm-d2ca up to 6 bedswith two no. 2 digit display card, acralic cover, in ms box of 275 x 225 x 50 mm bncm-d2cb up to 12 bedswith three no.2 digit display card, acralic cover, in ms box of 300 x 325 x 50 mm bncm-d2cc up to 18 bedswith four no. 2 digit display card, acralic cover, in ms box of 300 x 460 x 50 mm bncm-d2cd up to 24 bedswith five no.2 digit display card, acralic cover, in ms box of 350 x 550 x 50 mm bncm-d2ce up to 30 bedswith six no.2 digit display card, acralic cover, in ms box of 350 x 6000 x 50 mm bncm-d2cf up to 36 bedsdigital display board with 3digitdisplay with oneno. 3 digit display card, acralic cover, in ms box of 300 x 125 x 50 mm bncm-d3ca up to 5 bedswith two no.3 digit display card, acralic cover, in ms box of 300 x 225 x 50 mm bncm-d3cb up to10 bedswith three no.3 digit display card, acralic cover, in ms box of 300 x 350 x 50 mm bncm-d3cc up to 15 bedswith four no.3 digit display card, acralic cover, in ms box of 300 x 450 x 50 mm bncm-d3cd up to 20 bedswith fiveno.3 digit display card, acralic cover, in ms box of 300 x 550 x 50 mm bncm-d3ce up to 25 bedswith six no. 3 digit display card, acralic cover, in ms box of 600 x 475 x 50 mm bncm-d3cf up to 30 bedsdata logger card computer interferance card with softwar fitted in enclosure bncm-dlc -1 up to 36 beds.ups sytem power supply with automatic battery charger, smf 12 v. 7 ah battery bncmups1 up to 36 beds=1 setwires frombed tocallstation 2 pair telephone wire as per distance from bedsto call station

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Intelligent Queue Management System

We are offering intelligent queue management system. Organized waiting area enhanced customer experience micro-controller based system effective solution for hospital opds stand alone embedded system helps in organizing waiting area reduced manpower requirement cost effective introduction iqms from bps is effective queuing solution for hospitals opds. It helps in handling large number of patients to be attended by a number of doctors in an opd. iqms is stand alone system. It does not required any computer. It have its own cup, memory chips and hardware. its communication system is based on muti-tape bus wiring - new technology for secure communication and reduced wires. All control and display units are designed in house for utmost reliability. the system in totality is designed keeping in mind its demand for reliability. read more functional description opds in the hospital have number of reception counter & number of chambers for doctors. Each chamber may be offered to different doctor at different time slots. patient willing to consult any doctor can book his her appointment at any reception counter. Attendant at reception counter inserts particular doctors chamber number & slot no. And commands for taken printout. each reception counter is wired to a master controller which stores all information and allots token no on every new booking. Master controller also up-dates each chamber of latest booking thus keeping doctors informed of waiting patients. doctors chamber have display cum key unit. For call in next patent, he presses one key and the next token no. Is displayed out-sed the chamber or at common waiting area having central display unit. components - functions and selection depending on no of chambers and daily flow of patient, no of reception counteris to be decided. Each counter will have one reception counter terminal and one printer. reception counter terminals (rct) are table mounting type. They have heavy duty key board with 12 keys (10 keys for numbers and two function keys), lcd display with 16 char. 2 line display, parallel port output suitable for dot-matrix thermal printer. terminal bq-rct3 is suitable for printing 3" width paper. Bq-rct2 is for printing 2" width paper. Printer with thermal printing or dot-matrix printing can be connected with these terminals. bq-rct2p is built in printer of 2" width thermal paper. format of the token can be customized incorporating the name address, telephone number and other details of the hospital, chamber no. And slot no. Of the doctor, date of booking, sl. No. Of booking, etc. advantage to hospitals reduced man power requirement& thus save on operating cost. effective time management for doctorsas instant display of issue of current token ensures smooth sequential flow of patient & thus transparent queuing easy ticket printing, flexible systemto customize as requitement creates a good environment & enhancesthe goodwill of the hospital. opdqsoftqueue management system softwarefor organized opd experience bps offers new software based queue management system- opdqsoft. It is a service toolkit for managing and continuously improving service delivery forlargenumber of patients at hospital opds. the automated system tracks each customer's movement from initial point of entry to the final point of service delivery; giving managers have the ability to identify key events such service time and wait time exceptions, peak traffic, queue lengths, best performing staff members and many more statistics. in addition, the opdqsoft reporting system and mis reports provide top management with a real time view of service performance as it happens from any business location. doctors chamber key board with lcd display each chamber will have terminal unit with key board & 16 char. 2 line lcd display. It is connected with the master controller. It displays last no. Of token issued, current slot no, & current token no. On issuing of any new token, for the chamber and slot no, the displayis up-dated. The key board has a master button for calling in the next number. there are three type of units available. Bqdwm is wall mountable with membranes switches. Bqdtm is table mountable with heavy duty keys. Bqdtm-1 has only one heavy push button forcalling in the next patient. this helps the doctor in managing his time effectively and ensuring all the booked patients areconsulted. central display unit if the waiting area for the patients are common to all chambers, central display units are to queue1be installed. This is connected with master controller and displays token no. Against eachchamber no. Bqmdb-4 displays information for 4 chambers, bqmdb-6 is for 6 chambers. Token no. With 3 digits are display. Bqmdbs-4 & 6 are display board with display of tokenno. And slot no. If there are more number of chambers, multiple of such boards can be cascaded. master controller master controller is the central processing unit. It receives request from all the reception counter. It generate token number for each chamber. It also instructs the printer of reception counter for printing the token with all the details. It also up dates doctor chamber display board on issue of any new number. the unit has power supply unit built in and it powers all the terminals and doctors chambers. For power supply, it is to be connected with mains socket. The unit is wall mounting type, small in size. token display board at doctors chambers token display board is provide out side the chamber or on the wall in the waiting room space. when the doctor intend to call in the next patient, the called number is displayed at this board. There are 3 digits of 7 segment bright led. bqlds2 has two side display- 3 digits for token no. And 1 digit for slat no. Bqlds1 has single side display- 3 digits for token no. And 1 digit for slat no. Bqld1 has one side display- 3 digits for token no. item description model no quantity required. Receiption counter terminal key board table mounting type heavy duty key board, with 12 keys 16 char. 2 line lcd display, parallel port output suitable for dot-matrix thermal printer of 3" width paper bq-rct3 each counter = 1 with printer bq-rcpd3 or bq-rctd3table mounting type heavy duty key board, with 12 keys16 char.2 line lcddisplay, parallel port output suitable for dot-matrixthermal printer of 2" width paper bq-rct2 each counter = 1 with printer bq-rcpd2 or bq-rcpt2table mounting type heavy duty key board, with12 keys16 char. 2 line lcddisplay, built in thermal printer for 2" width paper bq-rct2p each counter = 1printer dot-matrix printer for 3" width paper with serial port input, bq-rcpd3 with bq-rct3dot-matrix printer for 2" width paper with serial port input bq-rcpd2 with bq-rct2thermal printer for 3" width paper with serial port input bq-rcpt3 with bq-rct3thermal printer for 2" width paper with serial port input bq-rcpt2 with bq-rct2doctor's chamber in chamber display & key board wall mounting display board with 16 char. 2 line lcd display &12 no. Of membrane switches for calling in patient bq-dwm each chamber = 1table mountable display board with 16 char. 2 line lcd display &12 no. Of heavy duty switches for calling in patient bq-dtm each chamber = 1table mountable display board with 16 char. 2 line lcd display &1 no. Of heavy duty push for calling in patient bq-dtm-1 each chamber = 1waiting area token no. Display double side two inch height seven segment led display-3 digit token no. 1digit slot no. bq-lds2 each chamber = 1single side two inch height seven segment led display-3 digit token no. 1digit slot no. bq-lds1 each chamber = 1single side two inch height seven segment led display-3 digit token no. 1digit slot no. bq-ld1 each chamber = 1master controller micro-controller based central processing unit sutable for up to 6 reception counter & up to 32 doctors chambers bqmp2w4c each station = 1central display unit common waiting area (optional) wall mounting type central token no. Display unit for up to 4 chambers with 3 digit token no.display bq-mdb-4 up to 4 chamber = 1wall mounting type central token no. Display unit for up to 6 chambers with 3 digit token no.display bq-mdb-6 up to 6 chamber = 1wall mounting type central token no. Display unit for up to 4 chambers with 3 digit token no.& 1 digit slot no. Display bq-mdbs-4 up to 4 chamber = 1wall mounting type central token no. Display unit for up to 6 chambers with 3 digit token no.& 1 digit slot no. Display bq-mdbs-6 up to 6 chamber = 1junction box for connecting between reception counter master controller doctors chamber key board and token display board bqmst4-2 no. Of doctor's chambers + 1cables & accessories cat 6 wire of 1 2 meter with both side terminalscat 6 wire for connecting to each chamber with master controller as per site installation

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Electronic Hooter

Electronic hooter power house offers i.c. Based solid state electronics hooters suitable for control panel / control desk and other alarm annunciation boards with many unique features. read more solid state:hooters are ic based with professional gradecomponents and hence more reliable than theelectro mechanical hooters which are subject tofrequent coil burnout. low power consumption: power consumption is less then 25% ofconventional electro mechanical hooters. wide input supply voltage: power house electronic hooters are available for different input supply voltage e.g. 12 v. Dc to 220 v. Ac multiple sound (4 in one): series peh4 has provisions for 4 incoming signals(12 v or 24 v). Positive signals from different faultlocation may be fed to the hooter. Each faultcondition will trigger a different sound. Withaddition of this facility, the attendant can visualizecause of fault from a distance and may approach with particular tools/ spares for particular fault removal. Thus saving of time. continuous rating: power house solid state hooters are tested for continuous operation. easy flush mounting: mounting is suitable for standard meter cuttingsize. (92x92 mm) select the ideal hooter modelno. soundvariety selectionpeh-1peh-2peh-3peh-4 single sounddouble soundfour soundfour sound switch/terminalswitch/terminalswitch/terminalautomatic* standard supply voltage 12v dc, 24 v dc, 30v dc, 220v ac.

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Boost Chargers

We are offering boost chargers. Function: power house fcbc are designed to supply continuous power to the dc load and simultaneously charge the batteries connected. Input supply form 415 v. Ac 3 phase or 220 v. Ac 1 ph. Is converted to regulate dc. The charger has two independent systems. Normally the dc power is supplied to he load by the float charger. Read more it also supplies trickle current to the battery to keep it healthy. If the charging current under float mode exceeds a set level, boost charger is switched on. It supplies quick charging current to the battery. On battery reaching the set value, the boost charger is switched off. Application: float/ boost chargers are must in power substations, generating stations, telephone exchanges etc. For control / monitoring systems, tripping circuits and supplying dc power source. specifications: aux: : 415v. Ac ( 3 phase) / 240 v (1 phase) +/- 20 %/ +/- 10%, 50 hz. +/- 3 hz. Out put : 30 v, 48 v, 110 v and 220 v. Dc supply battery type : lead acid / smfindications and instruments: indications for 3 phase mains supply: float / boost section: ac volt meter with selector switch : dc volt meter with selector switch and battery volt: dc amps meter for load: dc amps meter for charging. Protection : mcb for mains incoming supply: mcb for out put load: over load cut out by electronics circuit: over voltage cut-out by electronics circuit: single phasing, under voltage for mainshousing and enclosure:: heavy duty sheet steel enclosurefinished with powder coated paint. Mounting : floor mountingoperation : auto/manualcontrol : cc/ cv close looprectifier : full wave half controlled bridgeoptional : fuse protection for each rectifier element: fuse failure relay: dc earth fault relay: alarm annunciation: dual float charger option: any other as per requirement. ordering inffbormation:mains supply voltageload voltage and currentbattery type, voltage and currentany optional equipments required

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Automatic Source Changeover With Current Limiter

Automatic source changeover with current limiter- a perfect solution for power sharing automatic load changeover relay (plcr) - is a high precession system for efficient distribution of generator power in multi-storied apartments, commercial complexes etc. series plcr-ds are designed to connect mains supply to load till mains is present. on mains failure and receiving generator power, it connects the load to dg supply. During dg operation, load drawn is monitored. If the load exceeds the allotted limit, it disrupts the supply and rechecks in intervals. On reducing the load and keeping it within the limit, load is connected to dg supply. for different applications, we have specific models. They are with load limiter, without load limiter, transfer of load from one phase to other phase and many additional functions. automation at no extra cost. generator power to all lighting points. no separate wiring is required. assured availability of allotted currentspace savingtamper proof & maintenance free. safeguards generatorfully solid stateled indication wide range of single & three phase mode.

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Solid State Call Indicator

We are offering solid state call indicator. Power house solid state call indicators for offices, chambers, hotels, houses etc. Where one or more attendant is supposed to attend number of executives customer, occupant etc. the system is designed to replace conventional electro-mechanical buzzers- switch indicator assembly. In these systems, whenever the call is made, a magnet coil pulls an arm which in turn activisms a switch assembly switching the indicator on. The magnet coil is designed for 1-2 sec. Operation. But if some one keeps the bell push pressed for a little long time, or the bell push remains shorted for a while, the coil gets burned out resulting in chances of fires. the power house solid state call indication system does not have any coil switches or relays. The signal received is sensed by a electronics circuitry. It activates a led to indicate the call station number. Constant or repeated call signals does not effect its internal working in any way. The call can be re-set by push in the indicator board. It has a soft tone buzzer which sounds for a pre-set time on receipt of each signal. Elegant in look these indicators match the sophistication and decor of the place. with no moving parts, magnet coil, these are maintenance free device and totally safe from fire hazards. installation and wiring is very simple. These can just replace the conventional call indicators without any major changes in wiring. special models with sealed maintenance free, batteries and with built in cccv chargers are available. Non-attendance timer digital display, single reset, remote reset, battery backup are also available. selection chartmodelno. no. Ofways approx size(mm)bezel cut out depth cina01cina04cina06cina08cina12 146812 96x96152x102230x102230x102242x152 80x80135x80135x80210x80210x150 5050505050

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Dc Multi Function

We are offering dc multi function. bpmd-2tsd voltage: v1, v2( 0-200 v dc) ampere(0-50a ext. Shunt) auto scroll hold 4 digit display digital true rms dc volt v1 dc volt v2 dc current(50a75mv shunt) features: latest microcontroller based designspace saving compact designhigh speed 10 bit adcmoving average algorithmcrisp, bright, flicker-free led displaypre-calibrated metersrobust terminalssolid-state circuitry specification:aux optionsa. 240vac (+-20%)b. 85-265 acdcaccuracyclass 0.2display3 4 digits0.56" height reddimensions96x48cutout 92x4496x96cutout 92x92mountingpanel door

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Ac Multi Function

We are offering ac multi function. bpmd-2tsa voltage: v1, v2(0-500 v ac) frequency(auto ranging) auto scroll hold 4 digit display digital true rms . Ac volt v1ac volt v2frequency features: latest microcontroller based designspace saving compact designhigh speed 10 bit adcmoving average algorithmcrisp, bright, flicker-free led displaypre-calibrated metersrobust terminalssolid-state circuitry specification:aux optionsa. 240vac (+-20%)b. 85-265 acdcaccuracyclass 0.2display3 4 digits0.56" height reddimensions96x48cutout 92x4496x96cutout 92x92mountingpanel door

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Dc Volt

We are offering Dc Volt. BDPM-VD2 3 Digit DC Voltmeter Features: Crisp, Bright, Flicker-free LED DisplayPre-calibrated metersLatest LSI IC technologyAuto Polarity and Auto ZeroCompact DesignRobust TerminalsSolid-state circuitryInternational Styling Specification: Aux OptionsA. 240VAC(+-20%)B. 85-265 ACDCAccuracyClass 0.5Display3 4 Digits0.56" Height REDDimensions96x48Cutout 92x4496x96Cutout 92x92MountingPanel Door

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Dc Amps

We are offering dc ampere meter. bdpm-ad2 3 digit dc ampere meter features: crisp, bright, flicker-free led displaypre-calibrated meterslatest lsi ic technologyauto polarity and auto zerocompact designrobust terminalssolid-state circuitryinternational styling specification: aux optionsa. 240vac(+-20%)b. 85-265 acdcaccuracyclass 0.5display3 4 digits0.56" height reddimensions96x48cutout 92x4496x96cutout 92x92mountingpanel door

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

SMPS

We are offering smps. Features:universal input range (85 265 vac, 50 hz)undervoltage and overvoltage protectionover load and short circuit protection low working temperature. input surge current limiting. ultra compact power supply. industrial grade components. low ripple & noise. soft start. high efficiency. on board emi/rmi filterover temp shutdownreliable and cost efficient. screw/ jack type connectersadjustable output voltage +/- 10% (sel. Models) specification:ac input : 85 264 v ac (47-63 hz) / dcdc output : please ref. Output specificationripple/noise : less than 1% pk-pk (bw 20 mhz)over voltage : set at 125% (+/-5%) of output voltagewithstand voltage : i/p-o/p : 3kv. Line regulation : +/- 1% on full loadload regulation : on main of +/- 1%working temperature : 1060 deg.c. Efficiency : >75% typical @ full rated loadsafety standard : to comply with ul 1950, iec 950fusing : through mor/ glass fuse. Protection : overload, over voltage & shortcircuit protected. select the right supply voltage(volt) amperes(amp.) 5 1/2/3/5/1012 1/2/3/5/1024 1/2/3/548 1/2 multiple output models available on requestcustom made supplies made for your requirementspecial models available for battery chargingoptional paralleling facility with n+1 diode select the right supply:

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Microprocessor Based Solid State Alarm Annunciator

We offer microprocessor based solid statealarm annunciator. Function:annunciator is helpful to understand instantly from one place, the abnormal conditions of different process parameters i.e.temp. Pressure, tripping of any monitor relays. The system design is based on cmos technology providinghighest degree of reliability, ruggedness, flexibility, economyand aesthetics. it has built in push switches for test, accept, reset andsmall pizzo buzzer.test push is for instant versification of entiresystem.this triggers signal of all fault conditions resulting inflashing of all windows and actuation of hooter.external pushswitches and hooter can be connected through back connection. application:audio visual alarm for * process industry, * electrical panels, * d.g. Set panels, * chemical plants, * power plant. Etc, advanced microcontroller designoptically isolated inputsaux. 85-265 v acdc also available *long life super brightleds for each windows*low power consumption*compact size*standard din cut out*built in push switches*provision for externalpush switches*interlocking potentialfree relaymodel no. pand2-4 pand2-6 pand2-8 pand1-12 pand1-16 pand2-24number of channels 4 6 8 12 16 24 fault input potential free no contact can also be designed for voltage (potential) inputwindow size(h x w) 28 x 57mm 17 x 55mm 17 x 55mm 40 x 40mm 40 x 40mm 40 x 40mmlamps 4 nos. Of super bright red led slegends photo negative changeable from frontflash rate 40 flash per minpush switches test , accept, re-set push on front panel externalremote pushes can be connected from back terminalrelay out put rl1for hooter (potential free) 5 amp, rl 2 for interlocking (potential free) 5 ampaux supply 85 v 110 v 220 v 265 v ac, 12 v, 24 v, 48 v dc (pre-specified)operating temperature up to 50 degree c. (ambient)housing abs moulded sheet steel enclosuremounting standard din size panel enclosure panel cut out(h x w) 185 x 92mm 185 x 92mm 185 x 92mm 170 x 220mm 255 x 345mm 345 x 255mmoverall size(h x w x d) 190 x 94 x 150mm 190 x 94 x 150mm 190 x 94 x 150mm 183 x 235 x 180mm 280 x 370 x 70mm 370 x 280 x 70mminbuildpush button yes yes no no yes yesinbuildhooter no no no no yes no

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Emergency Light

We are offering emergency light. Function: emergency lights are designed to provide lights onpower interruption. These lights have built in * battery (smf type), * battery charger * change over circuitry and* inverter. Till the mains is on, the charger stores the energy in the battery. In the event of power failure, the stored energy is used to light up the tubes. application:to avoid accident and unwanted situations, these are must for! industries, ! hotels, ! railways stations, ! air ports theaters and! all public places. specifications: parameters edt-051 edt-054 eld-2 eld-3input volt 170v.-270 v. frequency 50hzbattery volt 6 12 6 12ah 4 7 10 7type smfnos. 1 2 1 2illumination tube / lamp 20 w. 40w 36w 20wnos. 1 1 1 2chargertype automatic cc/cv current max. 1 amp operation automatic on mains failure back-up time 2 hours ( approx.)protections mains glass fuse battery over chargingindications-led mainscharginghousing sheet steel powder coatedmounting wall mounting

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Water Level Controller,water Level Controller

We are offering water level controller. wl21p a low cost, reliable, ic based water level controllers. It keep constant watch on the water level and switch on or off the pump motors subject to availability of water at the reservoir and requirement level set at the upper tank. working principle: series pwl21p is designed to operate with electrode type to sense the water level. Stainless steel sensors with connector box are installed both at over head tank and reservoir. no dry run of motor and no over flow of water: sensors installed in the reservoir senses the availability of water in it. The sensors at the overhead tank is preset with a level at which the pump is to operate and switch off on reaching upper level. The pump is switched on only if the water is available at the reservoir. The system ensures no over flow from the overhead tank and no motor burn out due to dry running . auto/manual/off selection: the controller has auto/ manual/ off selection switch on the front panel. Under manual mode pump can be switch on manually, if the switch is in center- off position, motor remains off. This option may be required in emergencies and for cleaning up the electrodes or water tanks. protections: the controllers has built in protections for a) over/ under voltage protectionthe controller protects the motor from running at low/ high voltage thus saves the motor burnout. b) over load protection:electronics based over load circuit switches off the motor if load drawn exceeds the pre-set value and thus protects the pump motor from damages. indications:the controller is provided with following led indications: a) undervoltage b) overvoltage c) overload d) pumpon e) lowtank f) fulltank g) mainson housing:the controllers are housed in sheet steel enclosures finished with power coating paints. They are suitable for wall mounting. direct operation:up to 2 h.p. 1 ph. Phaseon demand, higher rating can be supplied.

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Fly Killer

We are offering fly killer. Flying insects killerthe battle with insects: flying insects are dangerous to mankind as they cause discomfort at working place become medium for spreading dangerous deseases, suck human blood and inject deadly germs in the body. Food beverages, sweets and eating items are poisioned and become unfit for human being. Safe & economical: pesticides and chemicalsare sprayed to control them but these methods have very temporary effects and also causes many new problems by polluting the atmosphere. It has been ecologically proved that ultra violet radiations has magnetic attraction to various flying insects like flies, mosquitoes, home flies, moths, etc. anu flykill is based on these discoveries and employs one/two special variety of ultra violet tube lights to attract these flying insects. A high voltage electrically charged guard is placed near by, which kills them instantly. Tray at the bottom is used to collect them. By these arrangements, flying insects do not drop here and there like in case of chemical sprays. Running cost of anu flykill is very negligible as no consumables are required except electricity. features different models for varying needs:- modelno. mounting tube areacoveredsq. Ft. No. lengthin inches wattspertubeakc21208akc21815akc22420 table/cornerwall/cellingwall/celling 222 121824 81520 300-500800-12001500-1800

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Auto Light Controller

We are offering auto light controller. function detects availability of natural lights and switches on/ off lights automatically. Optional built in off delay timer is also available. applicationauto light operation for external lighting. specification: aux. Supply : 240 v. Ac. selection chart model no. load in va sensor off delay timer switching dev. housingpalc 03 300 in built no relay surfacepalc10 1000 remote no relay surfacepalc25 2500 remote no relay surfacepalc10t 1000 remote yes relay surfacepalc25t 2500 remote yes relay surfacepalc5r 750 remote no relay railpalc5tr 750 remote yes relay railpalc5f 750 remote no relay flashpalc5tf 750 remote yes relay flashpalc10ss 1000 remote no solid state surfacepalc25ss 2500 remote no solid state surfaceplf10ss 1000 no sensor no solid state surfaceplf25ss 2500 no sensor no solid state surfaceplfr10 1000 no sensor no relay surfaceplfr25 2500 no sensor no relay surface sensors : ldrtimer : optional built inindication led : aux. Supply, : out put onmounting : panel / wall/ out door/enclosure : abs molded/ sheet steelout put : 3 a to 25 a. auto/ manual : toggle switch

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Magnetic Float Sensor

We are offering magnetic float sensor. Function:magnetic float switches / level sensor sare used to detect thesenor shave seale dreed switches in a stem with a permanentmagnet installed in the float.as float rises or falls, switch isactivated/deactivated. power house float sensor uses unique magnetic push at the floating magnet to respond fast to anychange of liquid level. features:unique magnetic liftsuitable for water/oil or fuel sensingeasy installationcan be installed directly on pipe specifications:level measurement type :point level switching capacity :10 w/vaswitching current :0.5 amp.max. Switching voltage :25 v dc max. Material :engineeringplastic cable :2coretemperature :-25 to 75c

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Micro Controller Based Nurse Call Monitoring System

We are offering micro controller based nurse call monitoring system. How to monitor and fix-up responsibility. to ensure the practice is followed, the system must be reliable and must have built in mechanism to point out delay in action. nurses call monitoring system series 640 informs the nursing staff the sequence of call received thus minimizing any over due call. The call register maintains sequence in which call from different bed are received. the first call pending is displayed with big 2 7 segment display. 4 other calls are displayed in the sequence of receipt. If more then 5 calls are pending, the same can be scrolled down. Any call attended is automatically erased and display is replaced with the next call pending. if any call is pending beyond set time, the number starts blinking. It also activates a buzzer to draw attention of the nursing staff. If call remains pending even beyond 2nd limit, rate of blinking is intensified to bring notice of problem. micro-controller based systemserial display of calls received-1st call displayed with 2" height leddisplay, next 4 calls in sequence on sidecolumn, further pending calls- onscrolling 3 digit 7 segment displays. soft tone buzzer- alerts receipt of new call elegant look compact and flexible- table- wall mountable. built in non attendance timer- pending calls flash- long pending calls flash at higher rates modular bed side console- easy installation in std. Modular cabinet status indicators and buttons- ready, call & wait led indicationon board, with call & reset switch elegant patient remote low voltage operation- the system works on 12 v. D.c hence patient is not put to danger even due toaccidental snatching of wires. reset at patient bed- re-set button installed near the patient. compact and flexible- the system requires very low space andis flexible to accommodates up to 64 beds. next generation system fromindustry leader leaders in nurses call monitoring system in india bps team is presenting the latest technical innovation in the line. The system is designed by our in house team to suit indian conditions. system over view series 640 consists of mainly the following sub-systems: a) call station boardb) patient remote hand setc) door indicatord) toilet pull corde) master controller hubf) nurses monitor console call station board each bed is provided with call station board. This is housed in standard console. It has push switches to call and re-set the call. led indications for ready(green), call(red), and wait(yellow) are provided. Ready led indicates that the system is ok and call can be made. If there is any problem with wiring, it will not glow. This is built in system to give instant check of any system or wiring fault. led marked call lights up when the call is made. Once the call is made and it is registered with the controller hub, led marked wait glows indicating call has reached nurse station. patient remote hand setfrom call station, remote patient hand set is provided so that the patient can make call form his bed. Remote hand set has push to make call. Led indication for ready, call and wait are provided. door indicatordoor indicator is installed out side the room to indicate call pending in the room. This facilitates nursing staff to attend on way to nurse station. One door indicator can announce pending call forup to 8 beds in the same room. Door indicators are available with many features like color leds, hold switch etc. toilet pull cord:toilet pull cord with indicator & rope. Standard length of rope is 1.5m. This pull cord is installed in side the toilet. Patient can use the pull cord in toilet. master controller hub:controller hub is central unit installed near nurse monitor console. It is consisting of one micro-processor central controller card, one connector card for up to 16 beds smps. Wires from all beds are terminated on connector pcb. It receives information fromeach bed and signals the console to display the information. nurses monitor consolethe call monitor console will be installed at the nurse center. Call received from any bed will be displayed by the respective bed number by 3 digit 7 segment led display. It can be mounted on wall or table stand. The first call pending is displayed with big 2 7 segment display. Other 4 calls are displayed in the sequence of receipt. If more then 5 calls are pending, the same can be scrolled down. Any call attended is automatically erased and display is replaced with the next call pending. connections:two pair telephone cable will be required to connect each bed to display board. Telephone type socket is punched to wires from each bed. Mains supply of 230 v ac is required at controller hub. low voltage operation:the incoming mains is converted to 12 v. D.c. In the power supply section and patient is not put to danger even due to accidental snatching of wires. re-set at patients bed:to re-set, the nurse or attendant has to press a button installed near the patient. This ensures attendance. compact and flexible:the system requires very low space and is flexible to add on as the number of beds increases. Marking on he indication board can be custom designed for easy location and is editable. our expertisenurses call monitoring systems and queue management systems by team bps is installed in all the leading hospitals in eastern india. With over 15 years of feed back from actual working condition in hospitals, continuous improvement in design, innovation of technology we are presenting series 640-the most advanced nurses call monitoring system. The system is designed with utmost reliability, dependability, safety, and flexibility in mind. ordering informationitem description model no. quantity reburiedcall station board with membrane push switches for call and re-set buttons& leds for ready, call and wait, connector for console connectionand connector for patient remote hand set bncm-pb640a each bed = 1 setpatientremote handset with flexible wire of 2 meters, telephone type jack connector, switch for call and indication for ready, call & wait bncm-pb640r each bed = 1 setdoor indicator with 8 nos red leds, red acrylic cover for connecting up to 8 bedsin one room bncm-du-1 optionalwith 3 colour leds, flash study off functions, acknowledge push, acrylic cover suitable for connecting up to 4 beds in one room bncm-du-2 for each roomtoilet pullcord toilet pull cord with indicatorrope length standard 1.5 m bncm-tpc1 for each toiletmaster controllerhub type-1 with one micro-processor central controller card, one connector cardfor up to 16 beds, power supplies (smps) housed in hinged cabinet bncm-mch640a up to 16 bedsmaster controllerhub type-2 with one micro-processor central controller card, two connector cardfor up to 32 beds power supplies (smps) housed in hinged cabinet bncm-mch640b up to 32 bedsmaster controllerhub type-3 with one micro-processor central controller card, three connector cardfor up to 48 beds power supplies (smps) housed in hinged cabinet bncm-mch640c up to 48 bedsmaster controllerhub type-4 with one micro-processor central controller card, four connector cardfor up to 64 beds power supplies (smps) housed in hinged cabinet bncm-mch640d up to 64 bedsnurse monitorconsole with one 2" height & 4 nos 34" height led displaysuitable for wall mounting and with table stand bncm-nch640a up to 64 bedsdata logger card computer interference card with softwarefitted in enclosure bncm-dlc-2 optionalup to 64 bedswires from bedto call station 2 pair telephone wire as per distance from beds tocall station

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Ac Volt

We are offering ac volt. bmpm-v3pr2 features: voltage:r, y, bauto scroll hold4 digit displaydigital true rms specification: latest microcontroller based designspace saving compact designhigh speed 10 bit adcmoving average algorithmcrisp, bright, flicker-free led displaypre-calibrated metersrobust terminalssolid-state circuitry aux optionsa. 240vac(+-20%)b. 85-265 acdcaccuracyclass 0.2display3 4 digits0.56" height reddimensions96x48cutout 92x4496x96cutout 92x92mountingpanel door

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details

Dc Drive

We are offering dc drive. 1/4 - 2.0 hp @ 230 vac 1-ph., 50 hz: 180v armature 1/8 - 1.0 hp @ 115 vac 1-ph., 50 hz: 90v armaturefor the operation of permanent magnet dc motors only. function:series pdcd dc drives are new generation of dc drives for 1/8 - 2 hp motors and for use on line supply voltages from 230 or 115 v ac. series pdcd dc drives are designed using the latest cmos technology which helps to reduce maintenance, increase product reliability and enables extremely rapid commissioning. features:easy to handle, install easy to design into machine equipmentfused ac input connectionscontrol speed from:- 10k ohm potentiometer included with drive (front panel)- external 10k ohm potentiometer- external input (0-10 v dc)- external input (4-20ma dc)speed regulation- 1% speed regulation armature voltage feedbackflush mounted operator devices:- power on/power off switch- power on indicator- speed potentiometeron-board leds for diagnostics:- power-on indication- fault indicationterminal block for easy usemonitoring functions:- overload- minimum field currentoptional setting for:- minimum speed : 0-35%- maximum speed: 75-100%- acceleration/deceleration: 0.5-17 sec. - armature over current trip application:dc drives are widely used for control of dc motors in various industries like:packaging equipment, conveyors, metering pumps, take-ups, mixers, material handling machines, exercise equipment, feeders, printing presses tapping machines, robotics and many more. specifications: aux. Supply : 240 v (ac) / 110 v (ac)output : 0 - 180 (v dc)/ 0 -90 (v dc)indication : led (power-on, fault )mounting : flushenclosure : abs molded dimensions : 96x192x150 (cutout 92 x 92reset : by system on-offswitch

Additional Information:

Payment Terms : L/C, Western Union

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us