Our Products
High Voltage Circuit Breaker
2 Products availablePower Contactors
2 Products availableElectric Control Panels
2 Products availableElectric Motors
2 Products availableRelays
2 Products availableAdaptors, Plugs And Sockets
2 Products availableElectrical Switches
2 Products availableOur Complete range of products are Outdoor VCB Kiosk With Cable Box, Outdoor VCB Kiosk With Roof Bushings and Outdoor Off Load Isolator.
Item (11 kV) | Width (w)(mm) | Depth (D)(mm) | Height (H)(mm) |
---|---|---|---|
100 to 500 KVA | 1600 | 2900 | 1825 |
630 to 1000 KVA with VCB | 2975 | 2050 | 2500 |
Unitized Sub Station-standard Components
HV compartment | Transformer compartment | LV compartment |
---|---|---|
Ring Main Unit (RMU) | Oil filled transformer OR Dry type/Cast resin transformer | Incomer air circuit breaker and distribution MCCBs with buiit in over current and short circuit protection |
internai lighting | Internal lighting | Metering (voltmeter and ammeter with selector switches) |
Compartment fitted with lockable swing handle and three point latch | Cable/bus bars for HV and LV Circuit breaker connection | Electrical indicators |
Over current &earth fault protection | Current transformers for metering | Internal lighting |
Door limit switch | Louvered covers | Space heater with thermostat control |
Boots for cable termination | Auxiliary supply plug &socket Compartment fitted with lockable swing handle and three point latch | |
Optional Accessories
|
LEDL Standard Motors
SI.No | Rating (kW) | RPM | Frame Size | Efficiency (%) | F.L.Current (AMPS) | P.F. |
---|---|---|---|---|---|---|
6-Pole Motors | ||||||
1 | 0.37 | 930 | LE80 | 70.0 | 1.1 | 0.67 |
2 | 0.55 | 910 | LE80 | 68.0 | 1.7 | 0.71 |
3 | 1.10 | 920 | LE90L | 73.0 | 3.0 | 0.74 |
4 | 2.20 | 975 | LE112M | 82.5 | 5.2 | 0.72 |
5 | 3.00 | 940 | LE112M | 80.0 | 6.8 | 0.80 |
6 | 7.50 | 960 | LE160M | 86.5 | 14.0 | 0.87 |
7 | 9.30 | 960 | LE160M | 88.5 | 18.0 | 0.85 |
8 | 15.00 | 975 | LE180L | 91.5 | 28.0 | 0.80 |
4-Pole Motors | ||||||
1 | 1.10 | 1440 | LE90L | 80.0 | 2.5 | 0.82 |
2 | 2.20 | 1410 | LE100L | 78.0 | 5.0 | 0.80 |
3 | 3.00 | 1400 | LE100L | 80.0 | 6.8 | 6.8 |
4 | 4.00 | 1430 | LE112M | 87.0 | 8.0 | 0.83 |
5 | 4.50 | 1450 | LE132S | 87.0 | 8.8 | 0.85 |
6 | 5.50 | 1430 | LE132S | 86.0 | 11.0 | 0.84 |
7 | 7.50 | 1440 | LE132M | 88.0 | 14.5 | 0.85 |
8 | 9.30 | 1450 | LE160M | 90.5 | 17.5 | 0.88 |
9 | 11.00 | 1460 | LE160M | 91.0 | 21.0 | 0.84 |
10 | 15.00 | 1450 | LE160L | 91.0 | 28.5 | 0.84 |
11 | 18.50 | 1450 | LE180L | 90.5 | 38.0 | 0.90 |
12 | 22.00 | 1475 | LE180L | 92.5 | 37.0 | 0.90 |
13 | 30.00 | 1470 | LE200L | 92.0 | 51.0 | 0.92 |
14 | 34.00 | 1470 | LE200L | 92.5 | 57.0 | 0.93 |
15 | 37.00 | 1470 | LE225S | 92.7 | 62.0 | 0.94 |
2-Pole Motors | ||||||
1 | 3.00 | 2810 | LE100L | 86.0 | 5.9 | 0.88 |
2 | 3.70 | 2880 | LE112M | 86.0 | 7.2 | 0.88 |
3 | 7.50 | 2910 | LE132M | 87.5 | 13.7 | 0.90 |
Flange Mounting - 'B'Type | ||||||
1 | 0.37 | 1410 | BLE80 | 75.0 | 0.9 | 0.75 |
2 | 3.70 | 1430 | BLE112 | 87.0 | 7.4 | 0.83 |
3 | 5.50 | 1440 | BLE132 | 86.0 | 11.0 | 0.84 |
4 | 7.50 | 1440 | BLE132 | 88.0 | 14.5 | 0.85 |
5 | 37.00 | 1470 | BLE225 | 92.7 | 62.0 | 0.94 |
6 | 11.00 | 960 | BLE160 | 89.5 | 21.0 | 0.84 |
7 | 22.00 | 975 | BLE200 | 91.3 | 41.0 | 0.84 |
Contact Rating
Make and carry continuously | Make and carry for 0.5 second | Break | |
---|---|---|---|
AC | 1250VA with maxima of 5A and 660V. | 7500VA with maxima of 30A and 660V | 1250VA with maxima of 5A and 660V |
DC | 1250W with maxima of 5A and 660V | 7500W with maxima of 30A and 660V | 100W (resistive) 50W (inductive) with maxima of 5A and 660V |
Dimensions And Weights
Maximum overall dimensions | ||||
---|---|---|---|---|
Relay | Case size | Cutout Size mm | Case Size mm | Approximate gross weight Kg. |
MCAG 14 | 1D vert | 150(W)x222(H) | 170(W)x233(H)x203(D) | 4.5 |
All Dimensions Are In MM
Rating | A | B | C |
---|---|---|---|
12kV | 900 | 2225 | 1850 |
24kV | 1000 | 2625 | 2400 |
36kV | 1500 | 2650 | 2400 |
Technical Spacification
Rating | Unit | MSK12 | MSK24 | MSK36 |
---|---|---|---|---|
Rated Voltage | kV | 12 | 24 | 36 |
Power Frequency withstaud Voltage | kV-rms | 28 | 50 | 70 |
Impulsewithstaud voltage | kVPeak | 75 | 125 | 170 |
Rated Frequency | Hz | 50 | 50 | 50 |
Rated Normal Current | A | 630/1250 | 630/1250 | 630/800 |
Short time CUrrent | kA | 25 | 25 | 25 |
Rated short circuit duration | Sec. | 3 | 3 | 3 |
Peak withstaud current | kA Peak | 62.5 | 62.5 | 62.5 |
Total Weight (approx) | kg | 900 | 1100 | 1250 |
Degree of protection (enclosure) | IP | IP55 | IP55 | IP55 |
Options : Cable entry from bottom can also be supplied on request. |
D | d | |
---|---|---|
3 kV to 12 kV | 200 | 140 |
15 kV to 24 kV | 320 | 250 |
27 kV to 36 kV | 420 | 330 |
<b>Technical Data For Vacuum Interrupter</b>
Electrical Rating (3 Phase Symmetrical bBasis) | Unit | GV-001 | GV-008 | GV-009 |
---|---|---|---|---|
Rated Maximum Line to Line Voltage | kV,r.m.s. | 36 | 12 | 12 |
Rated Normal Current | A,r.m.s. | 2000 | 2000 | 1250 |
Rated Frequency | Hz | 50/60 | 50/60 | 50/60 |
Rated Power Frequency withstand Voltage :Air | kV,r.m.s. | 70 | 36 | 36 |
Rated Impulse withstand Voltage :Air | kV, Peak | 170 | 95 | 95 |
Rated Short circuit current (3 Phase Symmertical Basis) | kA,r.m.s. | 26.3 | 26.3 | 26.3 |
Rated duration of short time current | Sec | 3 | 3 | 3 |
Percentage D.C. component of Rated S.C. Breaking current | % | 50 | 50 | 50 |
Rated Short circuit making current | kA, Peak | 67 | 67 | 67 |
Rated Short time withstand current | kA, r.m.s. | 26.3 | 26.3 | 20/ 26.3 |
Maximum contact Resistance at minimum closing force | micro ohms | 50 | 30 | 30 |
Capacitor Switching capacity (single bank) | A, r.m.s. | 400 | 400 | 400 |
Interrupter weight (Approx) | Kg | 8 | 2.9 | 2.5 |
Moving Part Weight (Approx) | Kg | 2.3 | 0.9 | 0.9 |
Contact force from armospheric pressure | Kg | 16.8 | 16.8 | 16.8 |
Requirements for Usage | ||||
Contact Stroke | mm | 20-22 | 6-8 | 6-8 |
Opening Speed (average of 75 5 contact gap) | m/sec | 1.4-1.6 | 1.0-1.3 | 1.0-1.3 |
Maximum over travel during opening | mm | 3 | 2 | 2 |
Maximum rebound during opening | mm | 2 | 1 | 1 |
Closing speed (average of last 30% contact gap) | m/sec | 0.9-1.2 | 0.7-1.0 | 0.7-1.0 |
maximum contact bounce duration (with max 2 bounces) | Sec | 0.002 | 0.002 | 0.002 |
Added contact force for rated S.C. making current | ||||
(Excl.contact force from atmp. pressure), at contact touch point | Kgf | 227-249 | 227-249 | 227-249 |
Final Force | Kgf | 230-280 | 230-280 | 230-280 |
Life expectancy | ||||
Electrical life at rated normal current | Operations | 20,000 | 30,000 | 30,000 |
Electrical life at rated short circut current | Operations | 100 | 100 | 100/ 35 |
Mechanical life | Operations | 30,000 | 30,000 | 30,000 |
Contact Erosion Limit | mm | 3 | 3 | 3 |
Shelf Life | Years | 20 | 20 | 20 |
Dimensions (D��H��h) | mm | 142.5x300x24. | 114x221x159 | 91x221x159 |
We are Listed At the Top among the Most Eminent Automatic Voltage Controller Suppliers in India. the Unmatched Quality and Inexplicable Performance of the Linear Type Automatic Voltage Controller Has Attracted Customers to Place Huge and Repeated Orders. Customers are also Facilitated with the Availability of the Automatic Voltage Controller At Pocket Friendly Prices. integral Distribution Transformers with Ht-avr, Wherein Ht Input Voltage is Stabilized Using Stepless Servo Regulator to Maintain Constant Output Voltage Within :1%. distribution Transformers with On-load Tap Change & Real-time Computer Control for Automatic Tap Changing On Ht Input Side to Maintain Stable Output Voltage dual Output Converter Transformers for Harmonic Compensation and Supply to 6p Drives, upto 2500 Kva&llkv Class. high Voltage Distribution System (hvds) Transformers upto 25 Kva & Llkv Class in Following Configurations: mitered Core or Wound Core. copper or Aluminum Wound. single Phase or Three Phase Supply
Customer Profile:<br>Reputed Existing Customers Include:
ABB | Alcatel | Ranbaxy |
---|---|---|
L&T | Fuji Films | Kalpataru |
BHEL | Areva T&D | Amar Ujala |
IVRCL | Bharti Airtel | Daurala Sugar |
Vodafone | SMA Infrasructure | Bhaskar Industries |