RESQ GT 33 Online UPS System

  • Phase: Single Phase, Three Phase
  • Application: Residential, Commercial
  • Weight: Upto 35 Kg
  • Form Factor: Tower Model
  • Condition : New

 Features

  • DSP technology guarantees high reliability
  • True galvanic isolation transformer
  • Compatible for all kind of loads
  • Intelligent battery management to prolong battery lifecycle
  • Independent ventilation enhance durable operation under harsh environment
  • Adjustable battery numbers
  • Accept dual-mains input (Optional)
  • Parallel operation up to LI units (optional)
  • Multiple Communication ports including MODBUS, USB, Dry contact, RS232 & SNMP (Optional)
  • Reverse phase frequency operation and supports non-neutral input

Specifications

Model RESQ30GT33 RESQ40GT33 RESQ60GT33 RESQ80GT33 RESQ100GT33 RESQ120GT33 RESQ160GT33 RESQ200GT33
Capacity 30KVA/24KW 40KVA/32KW 60KVA/48KW 80KVA/64KW 100KVA/80KW 120KVA/96KW 160KVA/128KW 200KVA1160KW
Output
Nominal Voltage 3 x 380VAC/400VAC (3Ph N)
Acceptable Voltage Range 285VAC - 475VAC
Frequency 50/60 Hz ± 10 %
Inverter
Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
Precision Stationary ± 1% Transitory: t5% (load variations 100% - 0% - 100%)
Frequency 50/60 He synchronised ±1 %With mains absent ±0.1 Hz
Max. Synchronisation Speed ±1 Hz/s
Waveform Pure Sinewave
Total Harmonic Distortion (THDv) <2% (Linear Load) <5% (Non-linear Load)
Phase Displacement 120° ± 1% (balanced load) 120°± 2% (imbalances upto 50% of the load)
Dynamic Recovery Time 3 cycles at 90 % of the static value
Admissible Overload 110% for 10min; 150% for 60sec ; >160% for 200ms
Admissible Crest Factor 3:1
Admissible Power Factor 0.6-1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load Current Limit <1%
Current Limit High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit
Static Bypass
Type Solid state
Voltage 3 x 380VAC/400VAC (3Ph + N)
Frequency 50/60 Hz
Activation Criterion Microprocessor control
Transfer Time Zero
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%
Retransfer Automatic after alarm clear
Maintenance Bypass
Type Without interruption
Voltage 3 x 400V (3Ph + N)
Frequency 50/60 Hz
Overall Efficiency
Line Mode 90.00% 91.00% 92.00%
Battery Mode 91.00% 92.00% 93.00%
Battery & Charger
Battery Type and Numbers 12VDC x 32 pcs (29-32 p. adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current *Default 10A; Maximum 40A; 5A@ full load
Charging Voltage 432 VDC (Based on 32pcs batteries)
Physical
Dimensions, D X W H(mm) 656x405x941 821x432x1159 975x554x1286 975x554x1326 1051x705x1646
Net weights (kgs) 193 278 365 471 573 650 760 840
View Complete Details

RESQ 1-10 KVA Online UPS System

  • Phase Single Phase with Ground
  • Power Capacity 1-10 KVA

Applications :

 
  • Mission critical applications and systems
  • Office Network and workstations
  • Servers
  • Medical Equipment's
  • Small and Large Data Centers
  • Computer Labs
  • PLC & Control Panels
  • Cash Machines [ATM's]
  • Printing Machines

Specifications

Model RES16KLB RESQ2KLB RESQ3KLB RESQ6KLB RESQ1OKLB
Phase Single phase with ground
Capacity 1000 VA/800 W 2000 VA/1600 W 3000 VA/2400 W 6000 VA/4800 W 10000 VA/8000 W
Input
Nominal Voltage 200/208/220/230/240VAC 208/220/230/24UVAC
Input Voltage Range 110-300 VAC (Based on load at 50%) 160-280VAC (Based on load at 100%) 110-300 VAC (Based on load at 50%) 176-300 VAC (Based on load at 100%)
Frequency Range 40Hz - 70 Hz 46-54 Hz or 56-64 Hz
Power Factor ≥0.99 @ Nominal Voltage (100% load)
Output
Output Voltage 200/208/220/230/240 VAC 208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode) ±1%
Frequency Range (Synchronized Range) 47~53Hz or 57-63Hz 46~54Hz or 56-64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz 50 Hz or 60 Hz ± 0.1 Hz
Crest Factor 3:1
Harmonic Distortion ≤3 % THD (linear Load) , ≤6 % THD (Non-linear Load) ≤3 % THD (linear Load) , ≤5 % THD (Non-linear Load)
Transfer Time
AC Mode to Battery Mode Zero
Inverter to Bypass 4 ms (typical) Zero
Waveform (Batt. Mode) Pure Sinewave
Efficiency
Overall Efficiency > 90%
Battery
Number of batteries 3 6/8 16/20
Charging Current (max.) 1A/2A/4A/6A (Adjustable) 1A/2A/4A/6A (Adjustable), 6A is only available for 16 pcs. Batteries)
INDICATORS
LCD Panel Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Alarm
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
overload Sounding twice every second
Fault Continuously sounding
Physical
Dimension, DXWXH (mm) 282x145x220 397x145x220 369x190x318 442x190x318
Net Weight (kgs) 4.1 6.8 7.4 12 16
Environment
Operation Humidity 20-90 % RH 0- 40°C (non-condensing)     0-95 % RH 0- 50°C (non-condensing) 0-95 % RH 0- 40°C (non-condensing)
Noise Level Less than 58dBA @ 1 Meter Less than55dBA @ 1 Meter Less than 58dBA @ 1 Meter
Management
Smart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, Windows. 7/8, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
Standards IP20, IEC62040-3, EN62040-1,2 COMPLIANCE : CE / ROHS
View Complete Details

RESQ 3/1- 10-30 KVA Online UPS System

  • Type Online Ups
  • Application Power Cut Solution
  • Color Black
  • Condition New
  • Automatic Grade Automatic
  • Driven Type Electric
  • Feature Easy To Install, Superior Finish
  • Phase Double Phase, Single Phase, Tripe Phase
Features: 
  • True Online Double Conversion
  • Advanced DSP Based Control for High Performance and Reliability
  • 0.9 output power factor
  • Active Power Factor Correction in all phases  more than 0.99
  • Wide input Voltage Range
  • 3-Stage Extendable charging design for optimized battery performance.
  • Built in phase auto adopt function simplifies wire installation
  • EPO function
  • ECO Mode for energy saving
  • Inbuilt maintenance bypass switch allows easy maintenance of UPS
  • optional- Intelligent monitoring and Software for better communication options.

Specifications

Model RESQ10KLB31 RESQ10KL31 RESQ15KL31 RESQ20KL31 RESQ30KL31
Phase 3 Phase in/ 3 phase Out
Capacity 10000 VA/8000 W 10000 VA/9000 W 15000 VA/13500 W 20000 VA/18000 W 30000 VA/27000 W
Input
Nominal Voltage 3 x 400 VAC (3Ph-N)
Voltage Range 190-520 VAC (3-phase) @ 50% load
Frequency Range 305-478 VAC (3-phase) @ 100% load
Power Factor ≥ 0.99 @100%load
ThDi < 6% @ 100% load
Output
Output Voltage 0.99 @ 100% load
AC Voltage Regulation (Batt. Mode) ±1%
Frequency Range (Synchronized Range) 46-54Hz or 56-64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Crest Factor 3:1
Harmonic Distortion ≤2 % THD (linear Load) , ≤5 % THD (Non-linear Load)
Transfer Time
AC Mode to Battery Mode Zero
Inverter to Bypass Zero
Waveform (Batt. Mode) Pure Sinewave
Efficiency
Overall Efficiency > 92%
Battery
Number of batteries 18 - 20 Adjustable
Charging Current (max.) 4A 4A 8A 8A 12A
Charging Voltage 273 VDC t 1% (Based on 20pcs batteries)
INDICATORS
LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Alarm
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
overload Sounding twice every second
Fault Continuously sounding
Physical
Dimension, DXWXH (mm) 442x190x318 592 x 250 x 826 592 x 250 x 576 592 x 250 x576 815 x 250 x 826
Net Weight (kgs) 16 28 40 40 64
Environment
Operation Humidity 0-95 % RH 0- 40°C (non-condensing)
Noise Level Less than 58dBA @ 1 Meter Less than 60dBA @ 1 Meter Less than 65dBA @ 1 Meter
Management
Smart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, Windows. 7/8, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
Standards IP20, IEC62040-3, EN62040-1,2 COMPLIANCE : CE / ROHS

 The information contained in this publication is subject to change without prior notice.

View Complete Details

RESQ-3/3 Online UPS System

  • Capacity: 5 KVA
  • Back Up Time: 1 Hour
  • Type: Online UPS
  • Form Factor: Tower Model
  • Input Voltage: 220-240 V

Application :

  • True Online Double Conversion
  • DSP technology guarantees high performance
  • 0.9 Output power factor
  • Active Power factor correction in all phases
  • ECO mode operation for energy saving (ECO)
  • Emergency Power off function( EPO )
  • Generator Compatible
  • High efficiency > 96 %
  • Optional: Dual-mains inputs (only for 10KVA/15KVA/20KVA )
  • 3-stage extendable charging design for optimized battery performance
  • Adjustable battery numbers
  • Maintenance bypass available
  • Optional N+X parallel redundancy

Specifications

Model RESQ10KL33 RESQ15KL33 RESQ20KL33 RESQ30KL33
Phase 3 Phase in/ 3 phase Out
Capacity 10000 VA/9000 W 15000 VA/13500 W 20000 VA/18000 W 30000 VA/27000 W
Input
Nominal Voltage 3 x 400 VAC (3Phi-N)
Voltage Range 190-520 VAC (3-phase) @ 50% load
Frequency Range 305-478 VAC (3-phase) @ 100% load
Power Factor 46-54 Hz or 56-64Hz
Output        
Output Voltage 0.99 @ 100% load
AC Voltage Regulation (Batt. Mode) 3 x 400 VAC (3Ph+N) ± 1%
Frequency Range (Synchronized Range) 46-54Hz or 56-64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Crest Factor 3:1
Harmonic Distortion 5 2 % THD (Linear Load) 5 5 % THD (Non-linear Load)
Transfer Time
AC Mode to Battery Mode Zero
Inverter to Bypass Zero
Waveform (Batt. Mode) Pure Sinewave
Efficiency
Overall Efficiency > 92%
Battery
Number of batteries 18 - 20 Adjustable
Charging Current (max.) 4A 4A 4A 12A
Charging Voltage 273 VDC t 1% (Based on 20pcs batteries)
INDICATORS
LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Alarm
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
overload Sounding twice every second
Fault Continuously sounding
Physical
Dimension, DXWXH (mm) 592 x 250 x 826 592 x 250 x 826 592 x 250 x 826 815 x 250 x 826
Net Weight (kgs) 38 40 40 64
Environment
Operation Humidity 0-95 % RH 0- 40°C (non-condensing)
Noise Level Less than 60dBA 0 1 Meter Less than 65dBA 0 1 Meter
Management
Smart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, Windows. 7/8, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
Standards IP20, IEC62040-3, EN62040-1,2 COMPLIANCE : CE / ROHS

The information contained in this publication is subject to change without prior notice.  

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of UPS from Jamshedpur, Jharkhand by Arise SK Power Solutions
Post Buy Requirement
Arise SK Power Solutions

Arise SK Power Solutions

gstGST : 20FZFPS5310N1Z8 Verified Add Review

Our Product / Services

  1. Batteries 5 Products available
  2. UPS 4 Products available
  3. Home Appliance Repair

    1 Services available
  4. Battery Maintenance Services

    1 Services available
  5. Electrical & Electronic Goods Repair

    1 Services available

UPS

Our product range contains a wide range of RESQ GT 33 Online UPS System, RESQ 1-10 KVA Online UPS System, RESQ 3/1- 10-30 KVA Online UPS System and RESQ-3/3 Online UPS System

RESQ GT 33 Online UPS System

  • Phase: Single Phase, Three Phase
  • Application: Residential, Commercial
  • Weight: Upto 35 Kg
  • Form Factor: Tower Model
  • Condition : New

 Features

  • DSP technology guarantees high reliability
  • True galvanic isolation transformer
  • Compatible for all kind of loads
  • Intelligent battery management to prolong battery lifecycle
  • Independent ventilation enhance durable operation under harsh environment
  • Adjustable battery numbers
  • Accept dual-mains input (Optional)
  • Parallel operation up to LI units (optional)
  • Multiple Communication ports including MODBUS, USB, Dry contact, RS232 & SNMP (Optional)
  • Reverse phase frequency operation and supports non-neutral input

Specifications

Model RESQ30GT33 RESQ40GT33 RESQ60GT33 RESQ80GT33 RESQ100GT33 RESQ120GT33 RESQ160GT33 RESQ200GT33
Capacity 30KVA/24KW 40KVA/32KW 60KVA/48KW 80KVA/64KW 100KVA/80KW 120KVA/96KW 160KVA/128KW 200KVA1160KW
Output
Nominal Voltage 3 x 380VAC/400VAC (3Ph N)
Acceptable Voltage Range 285VAC - 475VAC
Frequency 50/60 Hz ± 10 %
Inverter
Nominal Voltage 3 x 380VAC/400VAC (3Ph + N)
Precision Stationary ± 1% Transitory: t5% (load variations 100% - 0% - 100%)
Frequency 50/60 He synchronised ±1 %With mains absent ±0.1 Hz
Max. Synchronisation Speed ±1 Hz/s
Waveform Pure Sinewave
Total Harmonic Distortion (THDv) <2% (Linear Load) <5% (Non-linear Load)
Phase Displacement 120° ± 1% (balanced load) 120°± 2% (imbalances upto 50% of the load)
Dynamic Recovery Time 3 cycles at 90 % of the static value
Admissible Overload 110% for 10min; 150% for 60sec ; >160% for 200ms
Admissible Crest Factor 3:1
Admissible Power Factor 0.6-1 (inductive or capacitive)
Imbalance Output Voltage @ 100% Unbalanced Load Current Limit <1%
Current Limit High overload, short-circuit: RMS Voltage Limit High Crest-Factor current: Peak Voltage Limit
Static Bypass
Type Solid state
Voltage 3 x 380VAC/400VAC (3Ph + N)
Frequency 50/60 Hz
Activation Criterion Microprocessor control
Transfer Time Zero
Admissible Overload 150% for 1 hour; 180% for 30sec; >200% for 200ms
Transfer to Bypass Immediate, for overloads above 160%
Retransfer Automatic after alarm clear
Maintenance Bypass
Type Without interruption
Voltage 3 x 400V (3Ph + N)
Frequency 50/60 Hz
Overall Efficiency
Line Mode 90.00% 91.00% 92.00%
Battery Mode 91.00% 92.00% 93.00%
Battery & Charger
Battery Type and Numbers 12VDC x 32 pcs (29-32 p. adjustable)
Nominal Battery Voltage 384 VDC (Based on 32pcs batteries)
Charging Method CC/CV
Precision ±1%
Charging Current *Default 10A; Maximum 40A; 5A@ full load
Charging Voltage 432 VDC (Based on 32pcs batteries)
Physical
Dimensions, D X W H(mm) 656x405x941 821x432x1159 975x554x1286 975x554x1326 1051x705x1646
Net weights (kgs) 193 278 365 471 573 650 760 840
View Complete Details

RESQ 1-10 KVA Online UPS System

  • Phase Single Phase with Ground
  • Power Capacity 1-10 KVA

Applications :

 
  • Mission critical applications and systems
  • Office Network and workstations
  • Servers
  • Medical Equipment's
  • Small and Large Data Centers
  • Computer Labs
  • PLC & Control Panels
  • Cash Machines [ATM's]
  • Printing Machines

Specifications

Model RES16KLB RESQ2KLB RESQ3KLB RESQ6KLB RESQ1OKLB
Phase Single phase with ground
Capacity 1000 VA/800 W 2000 VA/1600 W 3000 VA/2400 W 6000 VA/4800 W 10000 VA/8000 W
Input
Nominal Voltage 200/208/220/230/240VAC 208/220/230/24UVAC
Input Voltage Range 110-300 VAC (Based on load at 50%) 160-280VAC (Based on load at 100%) 110-300 VAC (Based on load at 50%) 176-300 VAC (Based on load at 100%)
Frequency Range 40Hz - 70 Hz 46-54 Hz or 56-64 Hz
Power Factor ≥0.99 @ Nominal Voltage (100% load)
Output
Output Voltage 200/208/220/230/240 VAC 208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode) ±1%
Frequency Range (Synchronized Range) 47~53Hz or 57-63Hz 46~54Hz or 56-64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.25 Hz or 60 Hz ± 0.3 Hz 50 Hz or 60 Hz ± 0.1 Hz
Crest Factor 3:1
Harmonic Distortion ≤3 % THD (linear Load) , ≤6 % THD (Non-linear Load) ≤3 % THD (linear Load) , ≤5 % THD (Non-linear Load)
Transfer Time
AC Mode to Battery Mode Zero
Inverter to Bypass 4 ms (typical) Zero
Waveform (Batt. Mode) Pure Sinewave
Efficiency
Overall Efficiency > 90%
Battery
Number of batteries 3 6/8 16/20
Charging Current (max.) 1A/2A/4A/6A (Adjustable) 1A/2A/4A/6A (Adjustable), 6A is only available for 16 pcs. Batteries)
INDICATORS
LCD Panel Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Alarm
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
overload Sounding twice every second
Fault Continuously sounding
Physical
Dimension, DXWXH (mm) 282x145x220 397x145x220 369x190x318 442x190x318
Net Weight (kgs) 4.1 6.8 7.4 12 16
Environment
Operation Humidity 20-90 % RH 0- 40°C (non-condensing)     0-95 % RH 0- 50°C (non-condensing) 0-95 % RH 0- 40°C (non-condensing)
Noise Level Less than 58dBA @ 1 Meter Less than55dBA @ 1 Meter Less than 58dBA @ 1 Meter
Management
Smart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, Windows. 7/8, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
Standards IP20, IEC62040-3, EN62040-1,2 COMPLIANCE : CE / ROHS
View Complete Details

RESQ 3/1- 10-30 KVA Online UPS System

  • Type Online Ups
  • Application Power Cut Solution
  • Color Black
  • Condition New
  • Automatic Grade Automatic
  • Driven Type Electric
  • Feature Easy To Install, Superior Finish
  • Phase Double Phase, Single Phase, Tripe Phase
Features: 
  • True Online Double Conversion
  • Advanced DSP Based Control for High Performance and Reliability
  • 0.9 output power factor
  • Active Power Factor Correction in all phases  more than 0.99
  • Wide input Voltage Range
  • 3-Stage Extendable charging design for optimized battery performance.
  • Built in phase auto adopt function simplifies wire installation
  • EPO function
  • ECO Mode for energy saving
  • Inbuilt maintenance bypass switch allows easy maintenance of UPS
  • optional- Intelligent monitoring and Software for better communication options.

Specifications

Model RESQ10KLB31 RESQ10KL31 RESQ15KL31 RESQ20KL31 RESQ30KL31
Phase 3 Phase in/ 3 phase Out
Capacity 10000 VA/8000 W 10000 VA/9000 W 15000 VA/13500 W 20000 VA/18000 W 30000 VA/27000 W
Input
Nominal Voltage 3 x 400 VAC (3Ph-N)
Voltage Range 190-520 VAC (3-phase) @ 50% load
Frequency Range 305-478 VAC (3-phase) @ 100% load
Power Factor ≥ 0.99 @100%load
ThDi < 6% @ 100% load
Output
Output Voltage 0.99 @ 100% load
AC Voltage Regulation (Batt. Mode) ±1%
Frequency Range (Synchronized Range) 46-54Hz or 56-64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Crest Factor 3:1
Harmonic Distortion ≤2 % THD (linear Load) , ≤5 % THD (Non-linear Load)
Transfer Time
AC Mode to Battery Mode Zero
Inverter to Bypass Zero
Waveform (Batt. Mode) Pure Sinewave
Efficiency
Overall Efficiency > 92%
Battery
Number of batteries 18 - 20 Adjustable
Charging Current (max.) 4A 4A 8A 8A 12A
Charging Voltage 273 VDC t 1% (Based on 20pcs batteries)
INDICATORS
LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Alarm
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
overload Sounding twice every second
Fault Continuously sounding
Physical
Dimension, DXWXH (mm) 442x190x318 592 x 250 x 826 592 x 250 x 576 592 x 250 x576 815 x 250 x 826
Net Weight (kgs) 16 28 40 40 64
Environment
Operation Humidity 0-95 % RH 0- 40°C (non-condensing)
Noise Level Less than 58dBA @ 1 Meter Less than 60dBA @ 1 Meter Less than 65dBA @ 1 Meter
Management
Smart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, Windows. 7/8, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
Standards IP20, IEC62040-3, EN62040-1,2 COMPLIANCE : CE / ROHS

 The information contained in this publication is subject to change without prior notice.

View Complete Details

RESQ-3/3 Online UPS System

  • Capacity: 5 KVA
  • Back Up Time: 1 Hour
  • Type: Online UPS
  • Form Factor: Tower Model
  • Input Voltage: 220-240 V

Application :

  • True Online Double Conversion
  • DSP technology guarantees high performance
  • 0.9 Output power factor
  • Active Power factor correction in all phases
  • ECO mode operation for energy saving (ECO)
  • Emergency Power off function( EPO )
  • Generator Compatible
  • High efficiency > 96 %
  • Optional: Dual-mains inputs (only for 10KVA/15KVA/20KVA )
  • 3-stage extendable charging design for optimized battery performance
  • Adjustable battery numbers
  • Maintenance bypass available
  • Optional N+X parallel redundancy

Specifications

Model RESQ10KL33 RESQ15KL33 RESQ20KL33 RESQ30KL33
Phase 3 Phase in/ 3 phase Out
Capacity 10000 VA/9000 W 15000 VA/13500 W 20000 VA/18000 W 30000 VA/27000 W
Input
Nominal Voltage 3 x 400 VAC (3Phi-N)
Voltage Range 190-520 VAC (3-phase) @ 50% load
Frequency Range 305-478 VAC (3-phase) @ 100% load
Power Factor 46-54 Hz or 56-64Hz
Output        
Output Voltage 0.99 @ 100% load
AC Voltage Regulation (Batt. Mode) 3 x 400 VAC (3Ph+N) ± 1%
Frequency Range (Synchronized Range) 46-54Hz or 56-64Hz
Frequency Range (Batt. Mode) 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Crest Factor 3:1
Harmonic Distortion 5 2 % THD (Linear Load) 5 5 % THD (Non-linear Load)
Transfer Time
AC Mode to Battery Mode Zero
Inverter to Bypass Zero
Waveform (Batt. Mode) Pure Sinewave
Efficiency
Overall Efficiency > 92%
Battery
Number of batteries 18 - 20 Adjustable
Charging Current (max.) 4A 4A 4A 12A
Charging Voltage 273 VDC t 1% (Based on 20pcs batteries)
INDICATORS
LCD Panel UPS status, Load level, Battery level, Input/Output voltage, Discharge timer, and Fault conditions
Alarm
Battery Mode Sounding every 4 seconds
Low Battery Sounding every second
overload Sounding twice every second
Fault Continuously sounding
Physical
Dimension, DXWXH (mm) 592 x 250 x 826 592 x 250 x 826 592 x 250 x 826 815 x 250 x 826
Net Weight (kgs) 38 40 40 64
Environment
Operation Humidity 0-95 % RH 0- 40°C (non-condensing)
Noise Level Less than 60dBA 0 1 Meter Less than 65dBA 0 1 Meter
Management
Smart RS-232/USB Supports Windows® 2000/2003/XP/Vista/2008, Windows. 7/8, Linux and MAC
Optional SNMP Power management from SNMP manager and web browser
Standards IP20, IEC62040-3, EN62040-1,2 COMPLIANCE : CE / ROHS