Post Buy Requirement
PD
Vadodara, Gujarat, India
Add Review

Our Products

  1. Industrial Motors 3 Products available
  2. Electric Motors & Components

    1 Products available
  3. Electric Motors

    1 Products available
  4. Others Products 2 Products available

Industrial Motors #749280

Our offered Product range includes Brake Motor, Cooling Tower Motor and Enlarged Flange Motor.

Brake Motor

Brake motors are required when you want the motor to stop quickly even with heavy inertia/load like hoisting, positioning or material movement. "mototek" brake motors are becoming popular due to its practically maintenance free and noise less performance. "mototek" Brake motors are normally supplied with D.C. fail safe brakes, also known as normally ON brake. The motor is braked (Locked) when power is not applied i.e. de-energized to brake. This ensures real fail safe braking. The construction is quite robust and requires very limited maintenance. With wearing of liners on the rotor of brake, the air-gap can be easily adjusted. lf necessary, the rotor can be easily replaced completely as well. The brake is mounted on end covers on non-driving end of the motor. lt comes with a Manual release lever.

Selection Criteria

It is recommended to use proper size of brake. It should not be undersized or should not be over sized as well. Depending uponthe application, the service factor of the brake has to be selected for proper braking.Service factors for selection for the brake are mentioned in the selection table. This is just a guideline as there are many other factors to be considered while selecting the brake size like mounting positions, type of transmission and type and ratio of reductions. We request you to consult "mototek" for proper selection of brake size.

SUPPLY

Unless otherwise specified, brake voltages are 190 V DC with a rectifier of 415V A.C. dual phase input and 190V DC output duly fitted on the motor and properly connected with the terminals. For faster brake releasing action, 96 V D.C. brakes can be used with the some rectifier.-but with an input supply of 230V AC. Brakes with 24V or 48 V DC can be supplied but without rectifier. For these supply voltages brake, inbuilt rectifier is not available. Hence the brake has to be energized and de-energized external supply and controls.

SWITGHING

Motors are connected with AC switching as standard. For faster action i.e. reduction in the delay time in operation, DC switching can be used. Care must be taken while DC switching as it generates heavy sparking across the making and braking contacts which can lead to shorting of switching contacts and ultimately leads to failure of contact making or braking. This may become a cause of accident in some cases. Hence suitable universal shock suppressors and capacitors can be used which are normally not included in the "mototek" motors. Fast acting rectifiers are also available as well. Alternatively, 3 phase AC brakes can be used as well.

AIR-GAP ADJUSTMENT

The air gap between the armature of the brake and the plates is important as the braking torque and engage and disengage time of the brake. lt is recommended to verify and if required to adjust the air-gap periodically for consistent performance. It will not only improve the braking performance but will also increase the life of liner. The Brake is mounted on the rear end cover of the motor with three to six ellen bolts "L" near the outer periphery of the brake as indicated n the figure. These ellen bolts L'' pass through hollow hex bolts "H" which are in the opposite direction of the ellen bolts "L". Moving plate "M" is located between the armature and brake coil housing which moves axially during operation of engaging and disengaging. The air gap between this moving plate "M" and brake coil housing has to be maintained. It can be measured with a filler gauge or any other suitable measuring system. To set the air gap, loosen all the ellen bolts "L" and unscrew all the hollow hex bolts "H" slightly to increase air gap and tighten them to reduce the air gap. Tighten the ellen bolts "L" and measure the air gap near the bolts if required adjust the air gap again to achieve specified air gap as mentioned in the table.

OPTIONS

AC fail safe brakes and Normally off (energized to brake) brakes in different operating voltage can be supplied subject to confirmation. Motors with shaft extensions on rear side can be supplied if required for manual operation. A small handle can also be provided.

LENGTH OF BRAKE MOTORS

Dimensions of the brake motors are same except the total length. Length will be longer than the standard motors. Tentatively it will be as indicated in the table for motors with DC or AC fail safe brakes. For other types of brakes, please confirm the same.

OUTPUT 2-POLE 3000RPM 4-POLE 1500RPM 6-POLE 1000RPM 8-POLE 750RPM
KW HP FRAME Brake Safety FRAME Brake Safety FRAME Brake Safety FRAME Brake Safety
    Size Torque Factor Size Torque Factor Size Torque Factor Size Torque Factor
      in Nm     in Nm     in Nm     in Nm  
0.18 0.25 63 4.5 7.38 63 4.5 3.66 71 4.5 2.43 80 10 4.02
0.25 0.33 71 4.5 5.29 71 4.5 2.63 71 4.5 1.75 - - -
0.37 0.25 71 4.5 3.75 71 4.5 1.79 80 10 2.63 90S 10 1.95
0.55 0.75 71 4.5 2.39 71 4.5 1.20 - - - - - -
  - 80 10 5.32 80 10 2.67 80 10 1.77 90L 20 2.63
0.75 1.00 80 10 3.91 80 10 1.95 90S 20 2.60 100L 20 1.93
1.10 1.50 80 10 2.67 90S 20 2.67 90L 20 1.77 100L 40 2.63
1.50 2.00 90S 20 3.91 90L 20 1.96 100L 40 2.60 112M 40 1.93
2.20 3.00 90L 20 2.67 100L 40 2.66 112M 55 2.43 1325 60 1.97
3.00 4.00 100L 20 1.96 100L 40 1.96 132S 60 1.95 132M 85 2.05
3.70 5.00 100L 20 1.58 112M 60 2.38 1325 85 2.24 132M 150 2.93
5.50 7.50 112M 40 2.13 132S 85 2.27 132M 140 2.48 160M 150 1.97
7.50 10.00 132S 60 2.35 132M 140 2.74 160M 150 1.95 160L 250 2.41
9.30 12.50 132M 60 1.89 132M 150 2.36 160L 250 2.62 - - -
160M 85 2.68 160M 150 2.36 - - - 180M 250 1.94
11.00 15.00 160M 85 2.27 160M 150 2.00 160L 250 2.21 180L 250 1.64
15.00 20.00 160M 140 2.74 160L 250 2.44 180L 250 1.62 - - -
18.50 25.00 160L 150 2.38 180M 250 1.98 - - - - - -
22.00 30.00 180M 150 2.00 180L 250 1.67 - - - - - -

Frame Size 63 71 80 90 100 112 132 160 180
Air gap in mm 0.3 0.3 0.3 0.3 0.35 0.35 0.4 0.4 0.4

Frame Size 63 71 80 90 100 112 132 160 180
Air gap in mm 0.3 0.3 0.3 0.3 0.35 0.35 0.4 0.4 0.4
View Complete Details

Cooling Tower Motor

Many processes generates excess heat which is cooled by cooled water. The heated water is cooled by cooling towers. The motors for fan of cooling tower works under harsh conditions, the ambient temperature is quite high and highly moist surrounding. mototek cooling tower motors are protected with IP55 enclosure protection to minimize the entry of moisture inside the main motor body and terminal box. Efficiency and cooling are batter to withstand the higher ambient temperature. Being under continuous and loaded operation, energy saving is must. It is recommended to use higher efficiency motor for cooling tower. Bearing used are of rubber shield and for better radial loads, to ensure the efficient operation with longer life and minimum friction.

KW / HP RPM FRAME L Da La Db Lb Dc Lc M N P S T F Ga Gb
0.37 / 0.5 1500 71 178 17 55 14 25 M12 30 130 110 160 10 3 5 16 11
0.75 / 1.0 1500 80 200 20 60 19 50 M16 35 165 130 200 12 3 6 21.5 15.5
0.75 / 1.0 1000 90S 230 25 60 24 50 M20 40 165 130 200 12 3 8 27 20
1.1 / 1.5 1000 90L 230 25 60 24 50 M20 40 165 130 200 12 3 8 27 20
1.5 / 2.0 1000 100 258 30 60 28 50 M24 50 215 180 250 15 4 8 31 24
2.2 / 3.0 750 132S 321 40 60 38 50 M30 50 265 230 300 15 4 10 41 33
2.2 / 3.0 1000 112M 277 30 60 28 50 M24 50 215 180 250 15 4 8 31 24
3.7 / 5.0 1000 132S 321 40 60 38 50 M30 50 265 230 300 15 4 10 41 33
3.7 / 5.0 750 132M 340 40 90 38 75 M30 50 265 230 300 15 4 10 41 33
5.5 / 7.5 1000 132M 340 40 90 38 75 M30 50 265 230 300 15 4 10 41 33
5.5 / 7.5 750 160M 416 45 90 42 75 M30 50 300 250 350 19 5 12 45 37
7.5 / 10.0 1000 160M 416 45 90 42 75 M30 50 300 250 350 19 5 12 45 37
7.5 / 10.0 750 160M 416 45 90 42 75 M30 50 300 250 350 19 5 12 45 37
9.3 / 12.5 1000 160M 416 45 90 42 75 M30 50 300 250 350 19 5 12 45 37
9.3 / 12.5 750 180M 467 50 100 48 105 M30 50 300 250 350 19 5 14 51.5 42.5
11.0 / 15.0 1000 160M 416 45 90 42 75 M30 50 300 250 350 19 5 12 45 37
11.0 / 15.0 750 180M 467 50 100 48 105 M30 50 300 250 350 19 5 14 51.5 42.5
View Complete Details

Enlarged Flange Motor

Many application such as special purpose gearboxes, non continuous operating machines or motors having radial & axial loads need flanges smaller or larger or larger than the standard frame.

mototek motor are available with such flange.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

Retailer of Industrial Motors from Vadodara, Gujarat by POWER DRIVES (GUJ.) PVT. LTD.
Post Buy Requirement
PD

POWER DRIVES (GUJ.) PVT. LTD.

Add Review

Our Products

  1. Industrial Motors 3 Products available
  2. Electric Motors & Components

    1 Products available
  3. Electric Motors

    1 Products available
  4. Others Products 2 Products available

Industrial Motors

We offer a complete product range of Brake Motor, Cooling Tower Motor and Enlarged Flange Motor

Brake Motor

Brake motors are required when you want the motor to stop quickly even with heavy inertia/load like hoisting, positioning or material movement. "mototek" brake motors are becoming popular due to its practically maintenance free and noise less performance. "mototek" Brake motors are normally supplied with D.C. fail safe brakes, also known as normally ON brake. The motor is braked (Locked) when power is not applied i.e. de-energized to brake. This ensures real fail safe braking. The construction is quite robust and requires very limited maintenance. With wearing of liners on the rotor of brake, the air-gap can be easily adjusted. lf necessary, the rotor can be easily replaced completely as well. The brake is mounted on end covers on non-driving end of the motor. lt comes with a Manual release lever.

Selection Criteria

It is recommended to use proper size of brake. It should not be undersized or should not be over sized as well. Depending uponthe application, the service factor of the brake has to be selected for proper braking.Service factors for selection for the brake are mentioned in the selection table. This is just a guideline as there are many other factors to be considered while selecting the brake size like mounting positions, type of transmission and type and ratio of reductions. We request you to consult "mototek" for proper selection of brake size.

SUPPLY

Unless otherwise specified, brake voltages are 190 V DC with a rectifier of 415V A.C. dual phase input and 190V DC output duly fitted on the motor and properly connected with the terminals. For faster brake releasing action, 96 V D.C. brakes can be used with the some rectifier.-but with an input supply of 230V AC. Brakes with 24V or 48 V DC can be supplied but without rectifier. For these supply voltages brake, inbuilt rectifier is not available. Hence the brake has to be energized and de-energized external supply and controls.

SWITGHING

Motors are connected with AC switching as standard. For faster action i.e. reduction in the delay time in operation, DC switching can be used. Care must be taken while DC switching as it generates heavy sparking across the making and braking contacts which can lead to shorting of switching contacts and ultimately leads to failure of contact making or braking. This may become a cause of accident in some cases. Hence suitable universal shock suppressors and capacitors can be used which are normally not included in the "mototek" motors. Fast acting rectifiers are also available as well. Alternatively, 3 phase AC brakes can be used as well.

AIR-GAP ADJUSTMENT

The air gap between the armature of the brake and the plates is important as the braking torque and engage and disengage time of the brake. lt is recommended to verify and if required to adjust the air-gap periodically for consistent performance. It will not only improve the braking performance but will also increase the life of liner. The Brake is mounted on the rear end cover of the motor with three to six ellen bolts "L" near the outer periphery of the brake as indicated n the figure. These ellen bolts L'' pass through hollow hex bolts "H" which are in the opposite direction of the ellen bolts "L". Moving plate "M" is located between the armature and brake coil housing which moves axially during operation of engaging and disengaging. The air gap between this moving plate "M" and brake coil housing has to be maintained. It can be measured with a filler gauge or any other suitable measuring system. To set the air gap, loosen all the ellen bolts "L" and unscrew all the hollow hex bolts "H" slightly to increase air gap and tighten them to reduce the air gap. Tighten the ellen bolts "L" and measure the air gap near the bolts if required adjust the air gap again to achieve specified air gap as mentioned in the table.

OPTIONS

AC fail safe brakes and Normally off (energized to brake) brakes in different operating voltage can be supplied subject to confirmation. Motors with shaft extensions on rear side can be supplied if required for manual operation. A small handle can also be provided.

LENGTH OF BRAKE MOTORS

Dimensions of the brake motors are same except the total length. Length will be longer than the standard motors. Tentatively it will be as indicated in the table for motors with DC or AC fail safe brakes. For other types of brakes, please confirm the same.

OUTPUT 2-POLE 3000RPM 4-POLE 1500RPM 6-POLE 1000RPM 8-POLE 750RPM
KW HP FRAME Brake Safety FRAME Brake Safety FRAME Brake Safety FRAME Brake Safety
    Size Torque Factor Size Torque Factor Size Torque Factor Size Torque Factor
      in Nm     in Nm     in Nm     in Nm  
0.18 0.25 63 4.5 7.38 63 4.5 3.66 71 4.5 2.43 80 10 4.02
0.25 0.33 71 4.5 5.29 71 4.5 2.63 71 4.5 1.75 - - -
0.37 0.25 71 4.5 3.75 71 4.5 1.79 80 10 2.63 90S 10 1.95
0.55 0.75 71 4.5 2.39 71 4.5 1.20 - - - - - -
  - 80 10 5.32 80 10 2.67 80 10 1.77 90L 20 2.63
0.75 1.00 80 10 3.91 80 10 1.95 90S 20 2.60 100L 20 1.93
1.10 1.50 80 10 2.67 90S 20 2.67 90L 20 1.77 100L 40 2.63
1.50 2.00 90S 20 3.91 90L 20 1.96 100L 40 2.60 112M 40 1.93
2.20 3.00 90L 20 2.67 100L 40 2.66 112M 55 2.43 1325 60 1.97
3.00 4.00 100L 20 1.96 100L 40 1.96 132S 60 1.95 132M 85 2.05
3.70 5.00 100L 20 1.58 112M 60 2.38 1325 85 2.24 132M 150 2.93
5.50 7.50 112M 40 2.13 132S 85 2.27 132M 140 2.48 160M 150 1.97
7.50 10.00 132S 60 2.35 132M 140 2.74 160M 150 1.95 160L 250 2.41
9.30 12.50 132M 60 1.89 132M 150 2.36 160L 250 2.62 - - -
160M 85 2.68 160M 150 2.36 - - - 180M 250 1.94
11.00 15.00 160M 85 2.27 160M 150 2.00 160L 250 2.21 180L 250 1.64
15.00 20.00 160M 140 2.74 160L 250 2.44 180L 250 1.62 - - -
18.50 25.00 160L 150 2.38 180M 250 1.98 - - - - - -
22.00 30.00 180M 150 2.00 180L 250 1.67 - - - - - -

Frame Size 63 71 80 90 100 112 132 160 180
Air gap in mm 0.3 0.3 0.3 0.3 0.35 0.35 0.4 0.4 0.4

Frame Size 63 71 80 90 100 112 132 160 180
Air gap in mm 0.3 0.3 0.3 0.3 0.35 0.35 0.4 0.4 0.4
View Complete Details

Cooling Tower Motor

Many processes generates excess heat which is cooled by cooled water. The heated water is cooled by cooling towers. The motors for fan of cooling tower works under harsh conditions, the ambient temperature is quite high and highly moist surrounding. mototek cooling tower motors are protected with IP55 enclosure protection to minimize the entry of moisture inside the main motor body and terminal box. Efficiency and cooling are batter to withstand the higher ambient temperature. Being under continuous and loaded operation, energy saving is must. It is recommended to use higher efficiency motor for cooling tower. Bearing used are of rubber shield and for better radial loads, to ensure the efficient operation with longer life and minimum friction.

KW / HP RPM FRAME L Da La Db Lb Dc Lc M N P S T F Ga Gb
0.37 / 0.5 1500 71 178 17 55 14 25 M12 30 130 110 160 10 3 5 16 11
0.75 / 1.0 1500 80 200 20 60 19 50 M16 35 165 130 200 12 3 6 21.5 15.5
0.75 / 1.0 1000 90S 230 25 60 24 50 M20 40 165 130 200 12 3 8 27 20
1.1 / 1.5 1000 90L 230 25 60 24 50 M20 40 165 130 200 12 3 8 27 20
1.5 / 2.0 1000 100 258 30 60 28 50 M24 50 215 180 250 15 4 8 31 24
2.2 / 3.0 750 132S 321 40 60 38 50 M30 50 265 230 300 15 4 10 41 33
2.2 / 3.0 1000 112M 277 30 60 28 50 M24 50 215 180 250 15 4 8 31 24
3.7 / 5.0 1000 132S 321 40 60 38 50 M30 50 265 230 300 15 4 10 41 33
3.7 / 5.0 750 132M 340 40 90 38 75 M30 50 265 230 300 15 4 10 41 33
5.5 / 7.5 1000 132M 340 40 90 38 75 M30 50 265 230 300 15 4 10 41 33
5.5 / 7.5 750 160M 416 45 90 42 75 M30 50 300 250 350 19 5 12 45 37
7.5 / 10.0 1000 160M 416 45 90 42 75 M30 50 300 250 350 19 5 12 45 37
7.5 / 10.0 750 160M 416 45 90 42 75 M30 50 300 250 350 19 5 12 45 37
9.3 / 12.5 1000 160M 416 45 90 42 75 M30 50 300 250 350 19 5 12 45 37
9.3 / 12.5 750 180M 467 50 100 48 105 M30 50 300 250 350 19 5 14 51.5 42.5
11.0 / 15.0 1000 160M 416 45 90 42 75 M30 50 300 250 350 19 5 12 45 37
11.0 / 15.0 750 180M 467 50 100 48 105 M30 50 300 250 350 19 5 14 51.5 42.5
View Complete Details

Enlarged Flange Motor

Many application such as special purpose gearboxes, non continuous operating machines or motors having radial & axial loads need flanges smaller or larger or larger than the standard frame.

mototek motor are available with such flange.

View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us