Our Products
Electric Cutting Tools
2 Products availableOur product range contains a wide range of Falling Weight Impact Testers, Tensile Testers, Mobile Hardness Tester, Electrolytic Detection Permeability Tester and Oxygen Permeability Tester
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T, Western Union, ,
Packaging Details : own
Delivery Time : 6-8 weeks
This instrument is professionally applicable to the determination of water vapor transmission rate of plastic films, composite films, high barrier materials, back-sheets, sheeting, aluminum foils, waterproof materials, and other materials used in sanitary and medical industry. By testing the water vapor transmission rate, the technical indexes of materials could be controlled to meet the requirements for production.
Specifications | Film Test |
Test Range |
0.001 ~ 50 g/m2·24h (standard) 0.01 ~ 1000 g/m2·24h (optional) |
Number of Specimens | 1 |
Resolution | 0.1ppm |
Temperature Range | 5°C ~ 95°C |
Temperature Accuracy | ±0.1°C |
Humidity Range | 0%RH, 2%RH ~ 98.5%RH, 100%RH (standard is 90%RH) |
Accuracy | ±1%RH |
Test Area | 38.48 cm2 |
Thickness | < 1 mm (accessories required for thicker specimens) |
Specimen Size | Φ100 mm |
Carrier Gas | 99.999% High Purity Nitrogen (outside of supply scope) |
Gas Flow | 100 mL/min |
Gas Supply Pressure | ≥ 0.12 MPas |
Port Size | 1/8 inch copper tubing |
Instrument Dimension | 500 mm (L) x 400 mm (W) x 360 mm (H) |
Power Supply | 220VAC 50Hz / 120VAC 60Hz |
Net Weight | 36 kg |
OX2/231 is based on the equal pressure method, and is professional applicable to the determination of oxygen transmission rate of film and package products, including plastic films, composite films, sheeting, plastic bottles, plastic bags and other packages.
Specifications | Film Test |
Package Test (customization available) |
Test Range |
0.01 ~ 1000 cm3/m2·d (standard) 0.1 ~ 10,000 cm3/m2·d (optional) |
0.0001 ~ 10 cm3/pkg·d (standard) |
Number of Specimens | 1 ~ 3 | |
Resolution | 0.01 cm3/m2·d | 0.0001 cm3/pkg·d |
Temperature Range | 15°C ~ 55°C (optional) | / |
Temperature Accuracy | ±0.1°C | / |
Humidity Range |
0%RH, 15%RH ~ 90%RH, 100%RH (optional) |
|
Humidity Accuracy | ±1%RH | |
Test Gas | O2 and air (outside of supply scope) | |
Test Area | 50 cm2 | / |
Thickness | ≤3 mm (customization is available for other thickness) | / |
Specimen Size | 108 mm x 108 mm | Test in 100% O2: Specimen should be smaller than ?120 mm and lower than 360 mm |
Test in the Air: No size limitation | ||
Bottles: the inner diameter should be bigger than ?8 mm, outer diameter should be smaller than ?42 mm (Standard) | ||
Bags or Boxes: Supported by accessories | ||
Carrier Gas |
High purity nitrogen with more than 99.999% concentration (outside of supply scope) |
|
Gas Supply Pressure | ≥ 0.28 MPa | |
Port Size | 1/8 inch copper tubing | |
Instrument Dimension | 670 mm (L) x 410 mm (W) x 310 mm (H) | 670 mm (L) x 410 mm (W) x 630 mm (H) |
Power Supply | 220VAC 50Hz / 120VAC 60Hz | |
Net Weight | 48 kg | 50 kg |
MXD-01 Coefficient of Friction Tester is strictly based on GB 10006 standard, and is professionally applicable to the determination of static and kinetic coefficients of friction of plastic films, sheets, rubber, paper and paper board, PP woven bags, fabrics, metal-plastic composite belts for communication cables, convey belts, wood, coatings, brake pads, windshield wipers, shoe materials and tires. By testing the frictional properties of materials, the technical indexes could be controlled to meet requirements for production. Besides, the instrument can be used to measure smoothness of cosmetics, eye drops and other daily products.
Features
asic Applications | · Films |
· Paper and Paperboard | |
· Textiles, Non-woven Fabrics and Woven Bags | |
· Rubber | |
· Aluminum Foils, Aluminum Foil Composite Films, and Metal Products | |
· Printing Matters |
Extended Applications | · Wood and Flooring |
· Photographic Films | |
· Pipes | |
· Grains The instrument can test static and kinetic coefficients of friction of grains against the metal and other materials. |
|
· Hair The instrument can test static and kinetic coefficients of friction of the hairs. |
|
· Ball Shaped Materials The instrument can test static and kinetic coefficients of friction of the ball shaped materials against even leveled materials. |
|
· Medical Tubes The coefficients of frictions of catheters and nose feeding tubes against human skin have the direct affection on patient comfortable feeling. This instrument can test static and kinetic coefficients of friction of medical tubes against skin |
|
· Lacquered Wires This instrument can test static and kinetic coefficients of friction of the lacquered wires against even leveled materials. |
FPT-F1 Friction/Peel Tester can be used to test coefficient of static and kinetic friction of plastic films, sheets, foils, paper, cardboard, PP woven bags, fabric( fabric style test), metal-plastic composite strip/belt for communication cable, convey belt and textile, as well as peel strength test of adhesive laminated products, medical adhesive bandage, release paper and protection films.
pecifications | FPT-F1 |
Capacity Range | 0 ~ 5 N, 0 ~ 10 N, 0 ~ 30 N |
Accuracy | 0.5% FS |
Mass of Sled | 200 g, 500 g (Standard) |
100 g, 1000 g, 1814 g, 2000 g are optional | |
Test Speed | 50, 100, 150, 200, 250, 300, 500 mm/min |
Temperature | Room Temperature ~ 99.9°C |
Power Supply | 220VAC 50Hz / 120VAC 60Hz |
Instrument Dimension | 850 mm (L) x 350 mm (W) x 290 mm (H) |
Net Weight | 30 kg |
Basic Applications |
· Plastic Films and Sheets Coefficient of static and dynamic friction tests of plastic films and sheets |
· Paper and Paperboard Coefficient of static and dynamic friction tests of paper and paperboard |
|
· Textiles, Non-woven Fabrics and Woven Bags Coefficient of static and dynamic friction tests of textiles, non-woven fabrics and woven bags |
|
· Rubber Coefficient of static and dynamic friction tests of rubber products |
|
· Aluminum Foils and Aluminum Foil Composite Films Coefficient of static and dynamic friction tests of aluminum foils, aluminum foil composite films and other metal products |
|
· Printing Matters Coefficient of static and dynamic friction tests of printing matters |
Extended Applications |
· High Temperature Test Coefficient of static and dynamic friction tests at higher temperature than room temperature |
· Wood and Flooring Coefficient of static and dynamic friction tests of wood and flooring |
|
· Photographic Films Coefficient of static and dynamic friction tests of photographic films |
|
· Screen of Mobile Phone and Leather Coefficient of static and dynamic friction tests of mobile screens against the leather products |
|
· Adhesives Peeling test of the adhesive products |
|
· Medical Adhesives Peeling test of medical adhesives e.g. adhesive bandages and plasters |
|
· Protection Films Peeling test of protection films for mobile phones or computers |
|
· Magnetic Cards Peeling test of the films and magnetic cards |
PSST-100 Portable Heat Seal Strength Tester is designed for heat seal strength test of plastic films, composite films and other materials. This instrument is suitable for on-site quantitative inspection.
Basic Applications |
· Plastic Films, Sheets, Composite Films For heat seal strength tests of plastic films, sheets and composite films e.g. package for instant noodle, mill powder, washing powder as well as the external packages for food and drugs made of PE, PP, PET or composite films |
HST-H3 Heat Seal Tester is composed of upper and lower heat sealing jaws. Before the test, preset the heat seal temperature, pressure and dwell time value, place the specimen in between the upper and lower jaws, and then press start button. The whole sealing process can be finished automatically.
Basic Applications |
· Films with Smooth Surface Including plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films and many others. Heat sealing surface should be smooth and width can be designed based on user requirements. |
· Films with Decorative Pattern Surface Including plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films and many others. Heat sealing surface can be designed based on user requirements. |
Extended Applications |
· Covers of Jelly Cups The instrument is composed of the upper and lower jaws. The upper one is round-shape while the lower one is designed as a specimen mould whose size exactly fits the jelly cup. Put the jelly cup in the mould of lower jaw, and heat seal can be finished by upper jaw pushing. (Customization required) |
· Plastic Flexible Tubes The ends of plastic flexible tubes are placed in between upper and lower jaws and then sealed to form a package. |
CLASSIC 513 Gradient Heat Seal Tester is professionally designed for the determination of heatsealability of plastic films, composite films, coated paper, and other sealing films under certain sealing speed, pressure and 5 different temperatures. The heatsealability of heat sealing materials would be greatly affected by the factors of melting point, thermal stability, fluidity and thickness. The optimal heatsealability parameters can be obtained accurately and efficiently through this instrument.
Features
Professional Technology
Note1: There are five upper sealing jaws and five lower sealing jaws for heat seal test. The temperature of all the sealing jaws can be controlled independently. All of the sealing jaws are heated sealing jaws. The unheated sealing jaws can be selected as lower sealing jaws.
Note2: The 10 sealing jaws are all heated sealing jaws as required by ASTM F2029. If necessary, the lower sealing jaws can be replaced with unheated sealing jaws.
Basic Applications |
· Films with Smooth Surface Including plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films and many others. Heat sealing surface should be smooth and width can be designed based on user requirements. Instrument could simultaneously perform sealing operations at 5 different temperatures. |
· Films with Decorative Pattern Surface Including plastic films, plastic composite films, paper-plastic composite films, coextruded films, aluminized films, aluminum foils, aluminum foil composite films and many others. Heat sealing surface can be designed based on user requirements. Instrument could simultaneously perform sealing operations at 5 different temperatures. |
Extended Applications |
· Covers of Jelly Cups The instrument is composed of the upper and lower jaws. The upper one is round-shape, while the lower one is designed as a specimen mould whose size exactly fits jelly cup. Put the jelly cup in the mould of lower jaw, and sealing operation can be finished by upper jaw pushing. (Customization required) |
· Plastic Flexible Tubes The end of plastic flexible tubes is placed in between upper and lower jaws and then sealed to form a package. |
i-Thermotek 2400 Heat Seal & Hot Tack Tester can be used for heat seal test, hot tack test and heat seal strength test, which is applicable for determination of heat seal and hot tack properties as well as heat seal strength of the substrate materials of plastic film, flexible composite film, coated paper or other composite films.
Heat Seal Test | · Heat seal tests of various plastic films, plastic composite films, paper plastic composite films, co-extrusion films, aluminized films, aluminum foils and aluminum plastic composite films |
Hot Tack Test | · Hot tack tests of plastic films, sheeting and composite films such as PE, PP, PET or those composite films for instant noodle, washing powder and other food or drugs, etc. |
Heat Seal Strength | · Heat seal strength tests of various plastic films, plastic composite films, paper plastic composite films, co-extrusion films, aluminized films, aluminum foils and aluminum plastic composite films after heat seal test |
Heat Seal Test | Sealing Temperature | Room temperature~250 °C |
Sealing Pressure | 0.05 MPa~0.7 MPa | |
Dwell Time | ≤99.9s | |
Resolution | ±0.1°C | |
Accuracy | ±2°C | |
Temperature Gradient | ≤20°C | |
Sealing Area | 55mm×10mm | |
Number of Sealing Jaws | 3+1Note1 | |
Hot Tack Test | Sealing Temperature | Room Temperature~250°C |
Resolution | ±0.1°C | |
Accuracy | ±1°C | |
Dwell Time (Heat Seal) | ≤99.9s | |
Dwell Time (Hot Tack) | ≤20s | |
Sealing Pressure | 0.05~0.7MPa | |
Number of Sealing Jaws | 1+1Note2 | |
Capacity Range | 0~50N (Optional) | |
Test Accuracy | 1% FS | |
Resolution | 0.1N | |
Specimen Width | 15 mm or 25 mm or 25.4 mm | |
Heat Seal Strength | Capacity Range | 0~50N (Optional) |
Test Accuracy | 1% FS | |
Resolution | 0.1N | |
Specimen Width | 15 mm or 25 mm or 25.4 mm | |
Speed |
200mm/min, 250mm/min, 300mm/min (Customization is available) |
|
Stroke | 78.5 mm | |
Others | Gas Supply | Air (Outside of supply scope) |
Gas Supply Pressure | 0.05~0.7MPa | |
Port Size | Φ6 mm PU Tubing | |
Dimension | 500 mm (L) × 580 mm (W) × 575 mm (H) | |
Power Supply | 220VAC 50Hz / 120VAC 60HzNote3 | |
Net Weight | 50 kg | |
Configurations | Standard | Instrument (Including wireless data interface), Embedded Software, Standard LCD Monitor, Keyboard, Mouse, Calibration Frame, Pedal Switch, Sample Cutter and Valve tubing Set, Printer |
Optional | Strip Sample Cutter, Unheated Sealing Jaw, Air Compressor and Desiccant |
Load Cell Capacity | 200 N (standard) 30 N, 50 N, 100 N, 500 N (optional) |
750 N (Customization Available) | |
Accuracy | 1% FS |
Test Speed | 50, 100, 150, 200, 250, 300, 500 mm/min |
Number of Specimens | 1 |
Specimen Width | 30 mm (Standard Grip) |
50 mm (Optional Grip) | |
Sample Clamp | Manual Specimen Clamp |
Stroke | 600 mm |
Instrument Dimension | 450 mm (L) x 580 mm (W) x 1100 mm (H) |
Power Supply | 220VAC 50Hz / 120VAC 60Hz |
Net Weight | 61 kg |
BLD-200N Auto Stripping Tester can be used for peeling, stripping and other performance tests of adhesives, adhesive tapes, pressure sensitive tapes, medical adhesive bandage, protection films, release paper, laminated films, leatheroid, woven bags and paper.
Specifications | BLD-200N |
Capacity Range | 200 N (standard) 30 N, 50 N, 100 N, 500 N (optional) |
10N (Customization Available) | |
Accuracy | 1% FS |
Resolution | 0.01N |
Test Speed | 50, 100, 150, 200, 250, 300, 500 mm/min |
Specimen Width | ≤30 mm |
Stroke | 500 mm |
Instrument Dimension | 1000 mm (L) x 370 mm (W) x 400 mm (H) |
Power Supply | 220VAC 50Hz / 120VAC 60Hz |
Net Weight | 27 kg |
Basic Applications | · Tensile Strength and Deformation Rate |
· Tensile Strength at Break | |
· 180 Degree Peel Test | |
· 90 Degree Peel Test |
Extended Applications | · Tear Resistance | · Shearing Performance |
· Heat Seal Performance | · Low Speed Unwrapping Force | |
· Release Paper Peel Test | · Opening Force of Bottle Caps | |
· Adhesive Strength Test (soft) | · Adhesive Strength Test (hard) |
SLY-S1 is based on Elmendorf method to measure tearing strength of plastic films, textile, woven and non-woven materials. Labthink tear tester is a user-friend instrument and test range is from 200gf to 6400gf with suitable pendulum.
SLY-S1 Elmendorf Tearing Tester is designed for the tearing test of films, sheets, flexible PVC, PVDC, waterproof films, woven materials, polypropylene, polyester, paper, cardboard, textiles and nonwovens.
Features
Basic Applications | · Plastic films and sheets e.g. polyolefin, polyester and aluminum plastic composite films |
· Paper and Paperboard | |
· Textiles |
Extended Applications | · Heavy Package Bags |
· Rubber Gloves | |
· Wrapping Films | |
· Paper Metro Tickets |
BMC-B1 is designed for determination of mechanical properties of packaging materials such as plastic films, laminates and paper by a free falling dart from a certain height. This instrument is designed according to ASTM D1709 with method A & B.
Principle
Before starting the test, choose test method, and estimate an initial mass and m. Start the test. If the first specimen fails, decrease the mass of the falling dart by m. If the first specimen is not a failure, increase the mass of the falling dart by m. Continue the test according to this rule. In brief, increase or decrease by m according to whether the former specimen is a failure or not. After 20 specimens, calculate the total number of failed specimens N. If N equals to 10, the test is over. If N is less than 10, add specimens and continue to test until N equals to 10. If N is greater than 10, add specimen and continue the test until the number of non-failure specimens reaches 10. Then the tester calculates the test results automatically according to specific formulas.
Specifications | BMC-B1 |
Test Method | Method A or Method B is optional |
Test Range |
Method A: 50~2000 g Method B: 300~2000 g |
Accuracy | 0.1 g (0.1J) |
Specimen Clamp | Pneumatic Clamp |
Pressure of Gas Supply | 0.6 MPa (outside of supply scope) |
Port of Gas Supply | Φ8 mm PU Tubing |
Specimen Size | > 150 mm x 150 mm |
Power Supply | 220VAC 50Hz / 120VAC 60Hz |
Net Weight | 70 kg |
Instrument Dimension | Method A: 500 mm (L) x 450 mm (W) x 1320 mm (H) |
Method B: 500 mm (L) x 450 mm (W) x 2160 mm (H) |
Basic Applications | · Impact resistance test of plastic films, sheets and composite films e.g. PE preservative films, wrapping films, PET sheets and other food package and heavy packages |
· Impact resistance test of aluminum foils and aluminum plastic composite films | |
· Impact resistance test of paper and paper board |
Extended Applications | · Test the resistance of the specimen against the falling ball. Mount the specimen on specific clamp for falling ball impact test and select falling ball of certain weight for the impact test. Check the status of the specimen and determine the impact resistance of the specimen |
· Impact test of shoulder lining. Mount the shoulder lining specimen to the specified clamp and select falling dart of certain weight for impact test. Check the status of the specimen and determine the impact resistance of the shoulder lining specimen. |
FIT-01 can be used to determine impact resistance properties of pendulum of plastic films, sheets, composite films, aluminum foils and other materials in accordance with ASTM D3420.
FIT-01 Film Pendulum Impact Tester is professionally applicable to the determination of impact resistance properties of pendulum of plastic films, sheets, composite films, aluminum foils and other materials.
Principle
The impact resistance of films could be obtained by measuring the energy consumed by hemispheric impact head to make films ruptured, under the certain impacting conditions.
Basic Applications | · Including plastic films, sheets and composite films e.g. PE/PP composite films, aluminized films, aluminum plastic composite films, nylon films for food and drug packages |
· Including paper and paper board, e.g. aluminized paper for cigarette packages and Tetra Pak materials |
Extended Applications | · Test range could be extended to 5J |
RSY-R2 Film Free Shrink Tester is designed for the heat shrinkage test and size stability test of films, heat shrinkable pipelines, medical PVC sheets, back sheets and other materials in liquid medium at various temperatures.
This instrument is professionally applicable to the determination of heat shrinking performance and dimensional stability of various films, heatshrinkable tubes, hard PVC films for tablets, and back-sheets in the fluid medium at different temperatures.
Features
Basic Applications |
· Films The instrument can be used to test the heat shrinking performance of various films in fluid medium at different temperatures, e.g. PE heatshrinkable films used for packages of liquor, mineral water and beverages as well as PVC, POF, OPS, and PET which are available for various packages. |
|
Basic Applications |
· Paper Printing Materials Test the abrasion resistance of ink layers of printed materials and effectively analyze the problems of poor abrasion resistance and ink layer falling off |
· Photosensitive Coating Layers Test the abrasion resistance of photosensitive coating layers and effectively analyze the problems of lower printing force of PS boards. |
FDT-02 is professionally applicable to the determination of flex durability of flexible films, composite films, and coating films. The instrument can simulate the kneading and creasing behaviors of films happened during production, processing and transportation. The flex durability would be obtained by measuring the changes in number of pinholes or barrier properties after test, which could provide quantitative basis for package design and practical usage.
Features
Basic Applications |
· Flexible Films, Composite Films and Coating Films Including plastic films, sheets and composite films e.g. composite films, aluminized films, aluminum plastic composite films, nylon films and coating films for food or drug packages |
· Paper Materials Test the flex durability of paper materials |
Basic Applications |
· Deformation under Defined Load Test deformation under defined load of various corrugated cartons and beehive crates |
· Load under Defined Deformation Test load under defined deformation of various corrugated cartons and beehive crates |
|
· Maximum Load Test the maximum load of various corrugated cartons and beehive crates |
|
· Stack Test Stack test of various corrugated cartons and beehive crates |
Extended Applications |
· Plastic Casks, Mineral Water Bottles Compression test of plastic casks and mineral water bottles |
FT-F1 fogging tester is professionally designed for the fogging characteristics evaluation of volatile constituents of decorating materials used in cars and aircrafts, e.g. plastic articles, polyurethane, textiles, leather, adhesives, nonwovens and thermal forming elastomers at high temperature conditions. It also could be used for the fogging phenomenon test of high intensity discharge (HID) headlamps of cars.
Specifications | FT-F1 |
Temperature Range of High-Temperature Bath |
Room temperature ~ 150°C (room temperature ~ 280°C is optional) |
Accuracy | ±0.1°C (150°C) |
Temperature Range of Low-Temperature Bath | 0 ~ 100°C |
Accuracy | ±0.1°C |
Size of High-Temperature Bath | 670 mm (L) x 490 mm (W) x 540 mm (H) |
Size of Low-Temperature Bath | 400 mm (L) x 220 mm (W) x 520 mm (H) |
Net Weight of High-Temperature Bath | 32 kg (except the weight of heat conducting medium) |
Net Weight of Low-Temperature Bath | 15 kg (except the weight of heat conducting medium) |
Power Supply | 220VAC 50Hz / 120VAC 60Hz |
Basic Applications |
· Decorating Articles of Cars Test the volatility of car decorating articles, e.g. instrument boards, knobs, seat cushions, floor leather and ceiling materials at high temperature |
· Plastic Particles Test the volatility of plastic particles at high temperature |
Extended Applications |
· Carpets Test the volatility of carpets at high temperature |
· Leather Test the volatility of leather at high temperature |
|
· Sponge, Rubber and EPE Thermal Insulation Materials Test the volatility of sponge, rubber and EPE thermal insulation materials at high temperature |
|
· High Intensity Discharge Lamps For the fogging test of front high intensity discharge lamps of cars |
|
· Adhesive Products Test the volatility of adhesive products at high temperature |
Additional Information:
Payment Terms : L/C
Packaging Details : own packaging
Delivery Time : 6-8 weeks
CZY-6S Lasting Adhesive Tester can be used to test the holding power of pressure-sensitive tapes, medical plasters, pressure-sensitive labels and protective films, etc.
Test Principle
The test plate with adhesive specimen is vertically hanged on the stand and its bottom is attached with a standard weight. The lasting adhesive property could be obtained by measuring the displacement of specimen on vertical test plate or the time to failure at such load.
Specifications | CZY-6S |
Standard Roller | 2000 g ±50 g |
Weight | 1000 g ±10 g (with load plate) |
Test Plate | 60 mm (L) x 40 mm (W) x 1.5 mm (D) (Same as Load Plate) |
Timing Range | 0 ~ 99 h (standard) |
0 ~ 9999 h (optional) | |
Number of Stations | 6 |
Instrument Dimension | 600 mm (L) x 240 mm (W) x 400 mm (H) |
Power Supply | 220VAC 50Hz / 120VAC 60Hz |
Net Weight | 20 kg |
Applications
Basic Applications |
· GB/T 4851-1998 Including various adhesives, e.g. pressure-sensitive tapes, medical patches, adhesive labels and protection films |
Extended Applications |
· Pharmacopoeia standards Medical plasters |
ESM1500 | ESM1500S | ESM750 | ESM750S | |
Load capacity: |
1,500 lbF [6.7 kN] at < 60 in [1,525 mm]/min 1,000 lbF [4.5 kN] at > 60 in [1,525 mm]/min |
750 lbF [3.4 kN] at < 35 in [900 mm]/min 500 lbF [2.3 kN] at > 35 in [900 mm]/min |
||
Maximum travel distance: | 32.0 in [813 mm] | 14.2 in [360 mm] | 32.0 in [813 mm] | 14.2 in [360 mm] |
Standard speed range: | 0.5 - 24 in/min [10 - 600 mm/min] | |||
Available speed range: | 0.001 - 90 in/min [0.02 - 2,300 mm/min] | 0.001 - 60 in/min [0.02 - 1,525 mm/min] | ||
Speed setting accuracy: | ±0.2% of setting | |||
Speed variation with load: | ±0% [stepper motor driven] | |||
Travel accuracy*: | ±0.002 in. per 10 in. [±0.05 mm per 250 mm] | |||
Travel resolution: | 0.001 in [0.02 mm] | |||
Limit switch repeatability: | ±0.001 in [0.03 mm] | |||
Power: |
Universal input 80-240 VAC, 50/60 Hz, 450W |
Universal input 80-240 VAC, 50/60 Hz, 120 W |
||
Weight: | 198 lb [90 kg] | 160 lb [72 kg] | 185 lb [84 kg] | 150 lb [68 kg] |
Shipping weight: | 248 lb [113 kg] | 206 lb [93 kg] | 236 lb [107 kg] | 196 lb [88 kg] |
Warranty: | 3 years [see individual statement for further details] | |||
Conformance: | CE mark |
Employing the principle of cantilever bending, a rectangular specimen is supported on a smooth low-friction horizontal platform. A weighted slide is placed over the specimen and advanced at a constant rate. As the leading edge of the specimen projects from the platform, it bends under its own weight. The bend angle indicator can be set at either 41.5 (0.724 rad) or 45 (0.785 rad) below the plane of the platform surface, and includes an easy to read bend angle reference scale with 5 graduations. Once the material flexes enough to touch the bend angle indicator, the test is stopped. Using a scale calibrated in both metric and English units, the length of the overhang is then measured and flexural rigidity and bending modulus can be calculated.
The Fabric Stiffness Tester is available with or without the Hand Crank Speed Control Option. This feature allows the operator to control the rate of speed that the specimen is advanced.
NOTE: In general this instrument may not be suitable for very limp materials or those that show a marked tendency to curl or twist at a cut edge.
Additional Information:
Payment Terms : L/C, D/A, D/P, T/T, Western Union,
Packaging Details : own
Delivery Time : 6-8 weeks
Similar to Taber's Linear Abraser, a test attachment is secured to the bottom of a vertical spline shaft and accessory weights may be placed on a weight holder affixed to the top. A precision bearing on the spline shaft creates a "free-floating" test system. As the test arm moves in a linear motion, the "free-floating" system will raise or lower as the test attachment follows the contours of the specimen being tested - curved or flat.
The base load of 500 grams consists of the test attachment, spline shaft and weight holder. Accessory weights of 1000, 2000 and 4050 grams are included and can be added to the weight holder to increase the test load. With a high torque motor, the Heavy Duty Linear Abraser can accommodate a maximum testing load of 20 lbs. (weight sold separately).
Other features of the Heavy Duty Linear Abraser include a slotted roller channel allowing stroke length adjustments up to 330mm (13 inch); five preset speeds including 15, 30, 37, 45, and 60 cycles per minute; and an integrated T-slot table for securing specimens during testing.
With interchangeable attachments, the Heavy Duty Linear Abraser can also be configured similar to the Linear Abraser to evaluate the relative resistance or susceptibility of a material surface to wear and abrasion, scratch, gouge, scrape, rub, and more. In addition, the instrument can be used for both wet and dry testing. To increase test output, an optional second test arm kit may be added to perform two tests simultaneously.
The Taber Reciprocating Abraser includes a counterbalanced arm which pivots on an adjustable height gantry system. The counterweight allows the user to balance the test arm, ensuring precise test load set-up regardless of the weight of the attachment. Incorporated at the end of the arm is a tool holder to which optional attachments and weights may be secured. A sliding specimen platform moves in a horizontal, reciprocating motion under the stationary tool holder.
Test parameters such as stroke length (6 - 155mm), speed (3 - 75 cycles per minute) and load (1N - 24N maximum, with included weights of 1N, 2N, 2.5N, 5N, 10N & 24N) are adjustable so optimal settings for each material can be established.
To expand test loads, an optional weight support may be affixed to the top of the tool holder. This permits using auxiliary weight discs originally intended for Taber's Linear Abraser 5750 in place of the standard weights supplied with the instrument. Weight discs are sold individually and available as 10g, 20g, 50g, 75g, 100g, 150g or 250g.
The Wearaser collet assembly comes standard with each Taber Reciprocating Abraser, along with CS-10 and H-18 Wearaser abradants. The size and shape of a pencil eraser, the Wearaser is made using the same high quality Taber abrasive media found in our Genuine Taber abrading wheels. This permits the use of equivalent abrasive materials with the Reciprocating Abraser as well as Taber's Linear Abraser and the Taber Rotary Platform Abraser.
The standard specimen table provided with the Reciprocating Abraser is 216mm x 278mm (8.5" x 11") with drilled tapped holes to accommodate specimen clamps or optional specimen fixing plates. To evaluate most flat specimens, specimen clamps or the optional Wide Slot Fixing Plate may be suitable. For flexible materials such as textile products, the optional Specimen Fixing Plate Kit might be used. Products with a slight contour can also be secured in place using the specimen clamps provided or a custom fixture.
The Reciprocating Abraser can accommodate two additional test arm kits (sold separately), permitting up to three tests to be performed simultaneously.
Additional Information:
Payment Terms : T/T
Color Code | Gear Set-Up | Drive : Driven Ratio | Pin Holder RPM(Abraser turntable speed = 72 rpm) | Pin Holder RPM(Abraser turntable speed = 60 rpm) |
Orange | Standard | 0.9 : 1 | 65 | 54 |
Yellow | Reversed | 0.6 : 0.9 | 80 | 67 |
Red (optional) | Standard | 0.6 : 1 | 42 | 35 |
Green (optional) | Reversed | 1 : 1.7 | 123 | 103 |
Range | Stiffness Units | Sample Length | Roller Position | Sample Size | Range Weight | Angle of Deflection | Scaling Multiplier |
1 | 0 - 1 | 2cm | SR Attachment | 1.5" x 1.5" | 10 Unit Compensator | 15° | 0.01 |
2 | 0 - 10 | 1cm | Up | 1.5" x 1.5 | 10 Unit Compensator | 15° | 0.1 |
3 | 10 - 100 | 5cm | Down | 1.5" x 2.75" | - - - | 15° | 1 |
4 | 50 - 500 | 5cm | Down | 1.5" x 2.75" | 500 Unit | 15° | 5 |
5 | 100 - 1000 | 5cm | Down | 1.5" x 2.75" | 1000 Unit | 15° | 10 |
6 | 200 - 2000 | 5cm | Down | 1.5" x 2.75" | 2000 Unit | 15° | 20 |
7 | 300 - 3000 | 5cm | Down | 1.5" x 2.75" | 3000 Unit* | 15° | 30 |
8 | 500 - 5000 | 5cm | Down | 1.5" x 2.75" | 5000 Unit* | 15° | 50 |
9 | 1000 - 10000 | 5cm | Down | 1.5" x 2.75" | 5000 Unit* | 7 1/2° | 100 |
The Samples are immersed in a solution to drop the temperature. After three minutes at the desired temperature, the samples are hit with a striker of prescribed radius and speed. The operator then inspects the samples to see how many have failed.
The instrument has a built-in temperature controller, and with the optional liquid nitrogen control, allows the operator the ability to change the temperature and get to the new temperature quickly and accurately.
The Sample Holding Fixture can hold up to ten samples at one time. The amount of energy can be measured after each test to ensure consistent test results.
The instrument is manufactured of stainless steel, anodized aluminum and Epaint to ensure durability and longevity while maintaining an attractive look.
The BP2 requires a table area of 2' wide x 2' deep. An overhead clearance of 3' is recommended for the calibration tube.
The instrument runs on 110 volts 15 amp AC power, and a supply of liquid nitrogen set at 22 psi if the liquid nitrogen option is selected. It is also recommended that all precautions be taken with regard to the setup and handling of the liquid nitrogen and the resulting nitrogen gas.
The instrument comes complete with the test fixture, temperature chamber and calibration tube as noted in Annex A1. Options include the LN2 control, Sample Cutting Die, Torque Wrench and Sample Guide fixture.
Basic Applications |
· Adhesives Including various adhesives, e.g. pressure-sensitive tapes, medical patches, adhesive labels and protection films. |