Post Buy Requirement

Our Products

  1. Wire Making & Cabling Machines 3 Products available
  2. Clean Room Equipment 3 Products available
  3. Filters

    2 Products available
  4. Pharma Equipment & Machines

    1 Products available
  5. Laboratory Equipments

    1 Products available
  6. Commercial Air Conditioner

    1 Products available
  7. Housekeeping & Cleaning Services

    1 Products available
  8. Safety System & Equipments

    1 Products available
  9. Cars

    1 Products available
  10. Others Products 1 Products available

Other Products / Services

We offer the best product range of Garment Storage Cubicle.

Garment Storage Cubicle

Get from us an effective range of Garment Storage Cubicle fabricated using the latest technologies. Our Garment Storage Cubicle is designed to offer optimum protection for the samples and processes. Our Garment Storage Cubicle is manufactured as per the industrial standard to suit the varied customer’s demand. We provide the Garment Storage Cubicle in different sizes including SS 304 SS 316 SS 316l and CRCA powder coated. The Garment Storage Cubicle is equipped with a HEPA Filter to offer maximum prevention from contamination entering through the media of clothes.

Type of Units :

  • Vertical Garment Storage Cubicle
  • Horizontal Garment Storage Cubicle

 

Unit Description :

  • Construction are stainless steel body or crca powder coated
  • Differential pressure gauge
  • Milky light
  • Feather touch
  • Heater
  • Charcoal filters
  • Ultra violate light
  • Hour meter
  • Glass stainless steel door
  • Motor blower assemblies : 0.5 hp, 230 v, 1 phase, 50 hz
  • Hapa filters (final filter) : h13, efficiency 99.97% down to 0.3µ
  • Prefilters : eu6, efficiency 95% down to 5µ

Standard Model Specification

Model ACC-GC-8H ACC-GC-8V
HEPA Area 915 x 460mm 915 x 460mm
Working Dimension 930 (W) x 600 (D) x 1220(H)mm 915 (W) x 600 (D) x 1065(H)mm
Outer Dimension 1050 (W) x 700 (D) x 1800 (H)mm 1165 (W) x 600 (D) x 1600 (H)mm
Type Non FLP/ FLP Non FLP/ FLP

 

Clean Level 100 particles of size 0.5µ / F³
ISO Class 5 (ISO 14644-1:1999 (E))
Air Velocity 90 FPM (0.45MPS) ± 20 %
Noise Level <65 DB (A scale)

Note :

  • Garment Storage Cubical system is with a variety of standard dimensions. Also our booths can be custom engineered to any size.
  • Vibration <2.5m (0.0001”)
View Complete Details

Hvac System

You’ve probably heard of the term from different contractors, engineers, or perhaps colleagues and business partners; but you’re still wondering what the initialism means. Well, HVAC (“H-V-A-C” or “H-VAK”) stands for Heating, Ventilation, and Air-Conditioning—three closely related fundamental functions found in homes, offices, and other building structures. The beginning of HVAC is not clear, though as early as second century, a lot of Roman cities were using a central heating system known as hypocaust. This is further popularized during the Industrial Revolution as big factories used it. Now most modern buildings that you see have integrated HVAC. The HVAC system is also known as climate control. This is because these three functions are essential in maintaining comfort in every dwelling. The primary use of HVAC is to regulate room temperature, humidity, and air flow, ensuring that such elements remain within their acceptable ranges. Effective control of such factors minimizes health-related risks. A very humid atmosphere impairs the body’s ability to regulate body temperature as it prevents the evaporation of sweat. High humidity also decreases physical strength, which usually leads to fatigue. An unhealthy surrounding can also affect people’s thinking abilities. Hypothermia, heat stroke, and hyperpyrexia, among others, are some of the illnesses that may also occur.

 

Application of HVAC

  • Clean Rooms
  • Pharmaceutical Organization,
  • Hospital environments
  • Nano technology
  • Biotechnology
  • Micro electronics
  • Aerospace
  • Office spaces
  • Other Building facilities
View Complete Details

Modular Clean Room

Pharma Air Modular Systems Clean Room Partitioning System is designed for ease of installation and practical functionality, while maintaining modular flexibility to interchange by way of easy of demountability.
Whether you are adding on, modifying an existing facility, or constructing a new facility, the Pharma air modular systems panel system offers materials to suit your specific application.
The PAMS system can be integrated with a wide range of new or existing systems to coordinate any clean room facility or manufacturing environment. Simplified construction methods and our progressive/ non-progressive system will help minimise overall construction time.
Solid Panels for Clean Room PartitionsPharma Air Modular Systems monoblock/modular solid partitioning walls are fabricated by way of nominal 2x1/0.8/1mm hot dipped galvanized steel sheets conforming to JISG 3302/94, LFQ, light chromated, zero spangle with a zinc coating of 120gsm. They are bonded with an infill of honeycomb paper core or high density mineral wool, forming a rigid 80mm thick panel to modular widths of 160mm to 1200mm and 2445mm to 6000mm in height.
Pharma Air Modular Systems modular walls have been installed in clean rooms throughout the world in a range of applications from high technology electronic manufacturing to legislation-controlled healthcare packaging.
The system is readily adaptable to meet the requirements of most clean room classifications as determined by PAMS grades used in pharmaceutical applications. Make-up panels are produced within the sizing layout of the drawing. Pre-treatment of panels is done by way of Corro-Zinc 97 and epoxy polyester powder coating of 60/80 microns forming a smooth surface finish.
A complete range of partition walls and ceiling systems are available to meet the technical specifications of controlled environment rooms. Ceilings as well as partitions are inert, non particle-shedding, forming part of a clean room aseptic envelope to enable compliance with FDA validation procedures and PAMS standards.
Full details of the complementary range of ceiling systems are available on request.

 

Metal DoorsetsMetal doorsets are manufactured from prime quality stretched cold formed steel sheet to ASTM A527 ASTM A525, JISG 3302/1994, BS 2989. Door frames are pressed from 1.5 mm thick galvanized steel sheet with mitred and welded construction.
Hinge reinforcements for either 1 pair or 11/2 pair of hinges are manufactured from 4mm thick steel plate and welded to the frame.
The door leaf is manufactured from 0.8/1mm thick galvanized steel sheet with lock formed edges. It is insulated and bonded with infill of honeycombed paper core/mineral wool, forming a rigid flush-fitting stress-free level leaf that will withstand high levels of duty without failure.
Innovative flush double glazed 400x800mm vision panels are available, constructed with vacuum-sealed 6mm clear toughened glazing units. Finished in polyester powder coating of 60/80 microns forming a smooth surface finish.

 

Metal Type

  • Electro Galvanized Steel, EG (Pure Zn, ASTM A591)
  • Galvannealed Steel (with A60 Zinc Coating conformation to ASTM A25)
  • Cold Rolled Steel (ASTM 366-91)
  • Stainless Steel (Type 304 stainless steel, # 4 finish PVC coated)

The System

System 1200mm, 1000mm and 900mm as standard. Panel thickness 60/80/100mm. Ability to carry and conceal services and return air ducts/ risers.
Height Up to 6000mm with provision for stacked panels for higher application.
Base Detail Recessed adjustable base section to allow a flush coved finish.
Insulation Bonded mineral wool or polyisocyanurate foam cores assure absolute panel rigidity. Alternative cores available, such as honeycomb papercore/ aluminium.
Weight 9kg/m2 to 25kg/m2 dependant upon specification and thickness.
Surface Finish Electrostatically applied epoxy polyester powder coated finish applied in suitable RAL colours.
Panel Connection Each panel is connected to its adjacent unit or door unit with a friction-type interlocking key. This allows speedy erection and dismantling.
Glazing Double flush glazing with 6mm toughened glass on both sides within a stainless steel framing.
Doors Steel construction; optional double and single glazed apertures.
Acoustics Solid panel; Rw 41 dB - (BS 5821)
Coving Optionalradiused accessories. floor/ceiling coving
Air Leakage Silicone for sealed applications.

 

Standard Steel Sheet Thickness

Door 0.6mm (24 gauge), 0.8mm (22 gauge), 1.0mm (20 gauge) {Rolled Seams}
1.2mm (18 gauge), 1.6mm (16 gauge) {Welded Seams}
Frame 1.6mm (16 gauge) {Mitre/ welded corners and knock-down bolted frames}

 


Pharma Air Modular Systems Metal Doorsets And Frames (Model Specification)

Description Pharma Air Modular Systems Metal Doorsets and Frames
Construction

Door leaf from 1.0mm (1.2mm) (1.6mm) thick slip coated pre-galvanised steel sheet to ASTM A527/ ASTM A525, JIS G 3302 or BS 2989 (1994). Zinc coating 80-120 g/m2. Lock formed panels with internal stiffeners, 3.0mm thick hinge reinforcing, hardware mounting plates and lock protection.

Door frame from 1.2mm (1.6mm) (2.0mm) thick pre-galvanised steel sheet with mitred and welded corners, frame stretchers, hinge reinforcing plates, fixing plates and hardware mounting plates.

Core Materials Door leaf filled with either rockwool, honeycomb, infill dependant on duty.
Finish Powder coated surface.
Fixings Fixing through frame by expansion bolt.
Mortar straps.
Frame Assembly Welded construction with frame spreaders.
Bolted frame construction.
Knock-down frame construction for wrap around frames.
Panel Connection Glazing to door leaf.
Glazed overpanels in frames.
Glazing Louver panels to door leaves.
Fire resistant ventilators.
Louvers Up to 2 hours fire resistance in accordance with BS 476 Part 22 dependant on construction.
Fire Resistant Up to RW 44 for 60mm thick doorleaves with special frames and ancillary seals.
Acoustic Properties Up to 3000 mm high and 3000 mm wide subject to test data limitations.
Sizes Silicone for sealed applications.

 






Graph 01


Download Detail File : Click Here

Graph 02


Download Detail File : Click Here

Graph 03


Download Detail File : Click Here

Graph 04


Download Detail File : Click Here

Graph 05


Download Detail File : Click Here

Graph 06


Download Detail File : Click Here
View Complete Details

Sterilizing Tunnel

Our company specializes in offering qualitative range of Sterilizing Tunnel. This range of sterilization tunnels is designed using modern machinery, which makes these ideal for sterilization and drying of ampules and varied bottles like vials and oral liquid bottles in pharmaceutical industry. Along with this, the offered range is categorized in 3 wings (preheating zone, heating zone and cooling zone) in accordance with the diverse demands of clients.

View Complete Details

Fume Hood

A Fume Hood or fume cupboard is a type of ventilation device that is designed to limit the user's exposure to hazardous or noxious fumes, vapors or dusts. A fume hood is typically a large piece of equipment enclosing five sides of a work area, the bottom of which is most commonly located at a standing work height.

 

Fume hoods serve to control exposure to toxic, offensive or flammable vapors, gases and aerosols. Fume hoods are the primary method of exposure control in the laboratory.

 

Fume Hood cabinet inside Negative pressure, there for control exposure to toxic, offensive or flammable vapors, gases and aerosols.

 

Two main types exist, ducted and reticulating. The principle is the same for both types: air is drawn in from the front (open) side of the cabinet, and either expelled outside the building or made safe through filtration and fed back into the room.

 

Fume Hood is available in, SS 304 / SS 316 / SS 316L, CRCA Powder coated.

 

Unit Description

  • Construction are Stainless Steel Body OR CRCA Powder coated
  • Differential Pressure Gauge
  • Milky White Light
  • Feather Touch
  • Motor Blower Assemblies : 0.5 HP, 230 V, 1 phase, 50 Hz
  • HAPA Filters (Final Filter) : H13, Efficiency 99.97% down to 0.3µ
  • Exhaust HAPA Filters : H13, Efficiency 99.97% down to 0.3µ
  • Prefilters : EU6, Efficiency 95% down to 5µ
  • Ultra violate Light
  • Hour Meter
  • Sliding Glass Door

 

Optional Accessories

  • Stainless steel perforated grille for HEPA Filter
  • Filter blocked alarms

Standard Model Specification

Fume Hood is with a variety of standard dimensions. Also our booths can be custom engineered to any size.

Model ACC-FH
HEPA Area 1830 x 1220mm
Working Dimension 2075 (W) x 1420 (D)mm
Outer Dimension 2075 (W) x 1420 (D) x 1500 (H)mm
Type Non FLP/ FLP

 

Technical Specification

Clean Level 100 particles of size 0.5µ / F³
ISO Class 5(ISO 14644-1:1999 (E))
Light intensity > 300 lux
Air Velocity 90 FPM (0.45MPS) ± 20 %
Noise Level <65 DB (A scale)
Vibration <2.5m (0.0001”)
Power Supply ~230 V, 1 phase, 50 / 60 Hz

 

View Complete Details

HEPA Filters

We are offering to our customers HEPA Filters with high dust retention and flow rate. We offer the interchangeable HEPA Filters in different sizes to cater to varying the customer’s demand. The filter media is fire retardant assembled in a rigid aluminum frame. The filer medium also comprises a locking insert and is bonded in the frame using fire retardant adhesive. The fire retardant gasket of the HEPA Filters offer protection against leakages. We manufacture our HEPA Filters as per the standard industrial parameters. The particles are removed down to 0.3 micron from high particle airgas flow passing through the HEPA Filters with efficiency more than 99.97%. Having a large filtration area, the HEPA Filters are constructed from non-woven fiberglass media paper.

Types of HEPA Filter :

  • Minipleat HEPA Filter
  • High temperature HEPA Filter
  • Aluminum HEPA Filter (100% DOP)
  • Aluminum HEPA Filter (50% DOP)


Properties :

  • Resists to mildew
  • Resistant to fungal
  • Resistant to bacteria
  • Resistant to corrosive chemical fumes
  • Resistant to hydrofluoric acid


Features :

  • Easy handling
  • Easy cleaning
  • Easy removable
  • Easy install
  • Use to temp. Range (100o-600oc)
View Complete Details

Pre Filters

We are a reputed Manufacturer and Supplier of Pre Filters known for efficiency and high performance. Our Pre Filters remove all the particles down to 5 micron from high particle airgas passing through them. Our Pre Filters are very efficient offering an efficiency of more than 765 percent. Our Pre Filters are designed to ensure a large filtration area in ratio to the face area. The filter element of the Pre Filters is constructed from “glass fiber” papers, which is sandwiched between 2 layers for 5 micron and 1 layer for 10 micron. The filter media is fire retardant while the filter house is bonded on side using long life adhesive. The filter house is made from high-grade stainless steel sheet frame with flange.

Types of Pre Filters :

  • 3 Micron Pre Filter
  • 5 Micron Pre Filter
  • 10 Micron Pre Filter


Properties :

  • Resistant to mildew
  • Resistant to fungal
  • Resistant to bacteria
  • Resistant to corrosive chemical fumes
  • Resistant to hydrofluoric acid


Features :

  • Easy handling
  • Easy removable
  • Easy cleaning
  • Easy install
  • Use to temp. Range (100o-600oc).
View Complete Details

Stainless Steel Cleaning Cart

To move your sterile products in a safe manner, we are offering Stainless Steel Cleaning Cart. Backed by our highly competent team of professionals and sound infrastructure, we assure about the high performance of our Stainless Steel Cleaning Cart. Our Stainless Steel Cleaning Cart is mobile and light in weight due to which it can be used for transporting sterile products under ISO class 5 particle free work area. We offer the Stainless Steel Cleaning Cart in different varieties including SS 304 SS 316 SS 316L, CRCA powder coated.

Unit Description :

  • Construction : stainless steel body or CRCA powder coated
  • Differential pressure gauge
  • Glass stainless steel door
  • Milky light
  • Feather touch
  • Ultra violate light
  • Hour meter
  • 35 to 40 minute battery backup
  • Castor wheel
  • Motor blower assemblies : 0.5 hp, 230 v, 1 phase, 50 hz
  • HEPA filters (final filter) : h13, efficiency 99.97% down to 0.3µ
  • Pre filters : eu6, efficiency 95% down to 5µ

Technical Specifications

Model ACC-CC-4
HEPA Area 915 x 760mm
Working Dimension 410 (W) x 960 (D) x 800(H)mm
Outer Dimension 960 (W) x 960 (D) x 1525 (H)mm
Type Non FLP/ FLP

Clean Level

100 particles of size 0.5µ / F³

ISO Class

5 (ISO 14644-1:1999 (E))

Air Velocity

90 FPM (0.45MPS) ± 20 %

Noise Level

<65 DB (A scale)

Vibration

<2.5m (0.0001”)

Power Supply

~230 V, 1 phase, 50 / 60 Hz

Note : Mobile Clean Carte system is with a variety of standard dimensions. Also our booths can be custom engineered to any size.

View Complete Details

Biological Safety Cabinet

 When properly maintained and used in conjunction with good laboratory techniques, BSCs provide effective primary containment for work with human pathogens. In containment level 2 facilities, BSCs are used for procedures with the potential to produce infectious aerosols and for high concentrations or large volumes of infectious material. In containment levels 3 and 4, all open vessel activities with infectious materials are conducted in a BSC. Every employee working in a BSC must be trained in its correct use and have a good understanding of the different types of cabinets and how they work.

Classes and Characteristics of Biological Safety CabinetsThere are three classes of BSC: Class I, Class II and Class III. Selection of the proper class of BSC requires careful evaluation of the activities to be carried out. Horizontal, clean benches that direct air towards the operator are not biological safety cabinets and must not be used for handling infectious, toxic or sensitizing materials.

Class I Cabinets (Figures 1a and 1b)These cabinets have unrecirculated airflow away from the operator that is discharged to the atmosphere after filtration through a HEPA filter. They provide good operator protection but do not protect the material within the cabinet (the product) from contamination.

Class II Cabinets (Figures 2-5)Class II cabinets are designed for personnel, product and environmental protection. They are designed for work involving microorganisms in containment levels 2, 3 and 4 laboratories and are divided into two types (A and B) on the basis of construction type, airflow velocities and patterns, and exhaust systems.Within type (A), there are two subtypes, A1 (formerly designated type A) and A2 (formerly designated type B3). Within type (B), there are two subtypes, B1 and B2. Class II cabinets are most commonly used in biomedical research laboratories because of their characteristics.

Class II, Type A1 Cabinets (Figure 2)Cabinet air may be recirculated back into the laboratory or ducted out of the building by means of a "thimble" connection (i.e., a small opening around the cabinet exhaust filter housing) whereby the balance of the cabinet is not disturbed by fluctuations in the building exhaust system. The thimble must be designed to allow for proper certification of the cabinet (i.e., provide access to permit scan testing of the HEPA filter).Maintain a minimum average face velocity of 0.38 m/s (75 ft/min).May have positive pressure contaminated ducts and plenums. Are not suitable for work with low levels of volatile toxic chemicals and volatile radionuclides.

Class II, Type A2 Cabinets (Figure 3)

  • Cabinet air may be recirculated back into the laboratory or ducted out of the building by means of a "thimble" connection (i.e., a small opening around the cabinet exhaust filter housing) whereby the balance of the cabinet is not disturbed by fluctuations in the building exhaust system. The thimble must be designed to allow for proper certification of the cabinet (i.e., provide access to permit scan testing of the HEPA filter).
  • Maintain a minimum average face velocity of 0.5 m/s (100 ft/min).
  • Have ducts and plenums under negative pressure.
  • Is suitable for work with minute quantities of volatile toxic chemicals and trace amounts of radionuclides.

 

Class II, Type B1 Cabinets (Figure 4)

  • Hard-ducted through a dedicated duct exhausted to the atmosphere after passage through a HEPA filter; contain negative pressure plena.
  • Maintain a minimum average face velocity of 0.5 m/s (100 ft/min).
  • Recirculate 30% of the air within the cabinet.
  • Suitable for work with low levels of volatile toxic chemicals and trace amounts of radionuclides.


Class II, Type B2 Cabinets (Figure 5)

  • Does not recirculate air within the cabinet.
  • Maintain a minimum average face velocity of 0.5 m/s (100 ft/min).
  • Hard-ducted through a dedicated duct exhausted to the atmosphere, 100% of cabinet air, after passage through a HEPA filter; contain negative pressure plena.
  • Suitable for work with volatile toxic chemicals and radionuclides.

The exhaust canopy must allow for proper BSC certification. An alarm should be provided that is audible at the cabinet to indicate loss of exhaust flow from the building exhaust system. The cabinet internal fan should also be interlocked to shut down when the building exhaust system fan fails, to prevent pressurization of the cabinet.

Class III Cabinets (Figure 6)Class III cabinets are totally enclosed and gas-tight with HEPA filtered supply and exhaust air. Work is performed with attached long-sleeved gloves. The cabinet is kept under negative pressure of at least 120 Pa (0.5 in. w.g.), and airflow is maintained by a dedicated exterior exhaust system. Class III cabinets protect the worker and the product. They are designed for work with level 4 pathogens and provide an alternative to the positive-pressure suit made for maximum containment laboratories. Cabinet lines consisting of several Class III cabinets (e.g., for centrifuges, animal cages, incubators, refrigerators) and transfer devices joined together are traditionally custom built. Specific guidance on the unique requirements for constructing, installing, certifying and using Class III cabinet lines can be found elsewhere. The exhaust air is double HEPA filtered or treated by HEPA filter and incineration. Removal of materials from the cabinet must be through a dunk tank, double door autoclave or air-lock pass-through for decontamination. Interlock or protocols must be used for the autoclave and pass-through doors to prevent both doors from being open at the same time.

 

Use of the Cabinet
Follow these start-up procedures when preparing for work in the BSC :

  • Turn off UV lights if in use and ensure that the sash is in the appropriate position.
  • Turn on fluorescent light and cabinet blower, if off.
  • Check the air intake and exhaust grilles for obstructions.
  • If the cabinet is equipped with an alarm, test the alarm and switch it to the "on" position.
  • Confirm inward airflow by holding a tissue at the middle of the edge of the viewing panel and ensuring that it is drawn in.
  • Disinfect the interior surfaces with a suitable, noncorrosive disinfectant.
  • Assemble all materials required for the procedure and load them into the cabinet; do not obstruct the air grilles; the working surface may be lined with absorbent paper with plastic backing; segregate "clean" items from "contaminated" items.
  • Wait 5 minutes to purge airborne contaminants from the work area.


Follow these procedures for working in the cabinet :

  • Don protective clothing and gloves as appropriate.
  • Perform operations as far to the rear of the work area as possible.
  • Avoid movement of materials or excessive movement of hands and arms through the front access opening during use; when you do enter or exit the cabinet, do so from straight on; allow the cabinet to stabilize before resuming work.
  • Keep discarded, contaminated material to the rear of the cabinet; do not discard materials in containers outside of the cabinet.
  • Do not work with open flames inside the cabinet.
  • If there is a spill during use, surface decontaminate all objects in the cabinet; disinfect the working area of the cabinet while it is still in operation (do not turn the cabinet off).


Follow these procedures upon completion of the work :

  • Allow the cabinet to run for 5 minutes with no activity.
  • Close or cover open containers before removing them from the cabinet.
  • Surface disinfect objects in contact with contaminated material before removal from the cabinet.
  • Remove contaminated gloves and dispose of them as appropriate; wash hands.
  • Don clean gloves, and ensure that all materials are placed into biohazard bags within the cabinet.
  • Using a suitable non-corrosive disinfectant (e.g., 70% ethanol), disinfect interior surfaces of cabinet; periodically remove the work surface and disinfect the area beneath it (including the catch pan) and wipe the surface of the UV light with disinfectant.
  • Turn off the fluorescent light and cabinet blower when appropriate (some cabinets must be left on at all times; if you are unsure, check with your cabinet certifier, safety officer or building maintenance personnel).
  • Turn on the UV light if appropriate (do not turn on when people are working close by); UV must be tested to ensure that it is emitting a germicidal wavelength (ask your cabinet certifier to perform this test).


Unit Description

  • Construction are Stainless Steel Body OR CRCA Powder coated
  • Differential Pressure Gauge
  • Milky White Light
  • Feather Touch
  • Motor Blower Assemblies : 0.5 HP, 230 V, 1 phase, 50 Hz
  • HAPA Filters (Final Filter) : H13, Efficiency 99.97% down to 0.3µ
  • Prefilters : EU6, Efficiency 95% down to 5µ


OPTIONAL ACCESSORISE

  • Stainless steel perforated grille for HEPA Filter
  • Glove ports
  • Filter blocked alarms
  • Stands
  • Hour meter
  • Ultraviolet light

Biological Safety Cabinet is with a variety of standard dimensions. Also our booth.

Figure 1a


Download Detail File : Click Here

Figure 1b.


Download Detail File : Click Here

Figure 2


Download Detail File : Click Here

Figure 3


Download Detail File : Click Here

Figure 4


Download Detail File : Click Here

Figure 5


Download Detail File : Click Here

Figure 6


Download Detail File : Click Here

Technical Specification

Clean Level 100 particles of size 0.5µ / F³
ISO Class 5(ISO 14644-1:1999 (E))
Light intensity > 300 lux
Air Velocity 90 FPM (0.45MPS) ± 20 %
Noise Level <65 DB (A scale)
Vibration <2.5m (0.0001”)
Power Supply ~230 V, 1 phase, 50 / 60 Hz
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • B N Patil (Pharma Air Modular Systems)
  • 213, Vikas Height, 2nd Floor, Opp. HDFC Bank, Santoshi Mata Mandir Road, Kalyan (West), Kalyan West, Thane, Maharashtra - 421301, India
  • Share us via
  • Call 08068051345 Ext. 766
List of Other Products by Pharma Air Modular Systems from Thane, Maharashtra.
Post Buy Requirement

Our Products

  1. Clean Room Equipment 3 Products available
  2. Wire Making & Cabling Machines 3 Products available
  3. Filters

    2 Products available
  4. Housekeeping & Cleaning Services

    1 Products available
  5. Safety System & Equipments

    1 Products available
  6. Cars

    1 Products available
  7. Pharma Equipment & Machines

    1 Products available
  8. Laboratory Equipments

    1 Products available
  9. Commercial Air Conditioner

    1 Products available
  10. Others Products 1 Products available

Other Products / Services

We are leaders in the market for providing best range of Garment Storage Cubicle

Garment Storage Cubicle

Get from us an effective range of Garment Storage Cubicle fabricated using the latest technologies. Our Garment Storage Cubicle is designed to offer optimum protection for the samples and processes. Our Garment Storage Cubicle is manufactured as per the industrial standard to suit the varied customer’s demand. We provide the Garment Storage Cubicle in different sizes including SS 304 SS 316 SS 316l and CRCA powder coated. The Garment Storage Cubicle is equipped with a HEPA Filter to offer maximum prevention from contamination entering through the media of clothes.

Type of Units :

  • Vertical Garment Storage Cubicle
  • Horizontal Garment Storage Cubicle

 

Unit Description :

  • Construction are stainless steel body or crca powder coated
  • Differential pressure gauge
  • Milky light
  • Feather touch
  • Heater
  • Charcoal filters
  • Ultra violate light
  • Hour meter
  • Glass stainless steel door
  • Motor blower assemblies : 0.5 hp, 230 v, 1 phase, 50 hz
  • Hapa filters (final filter) : h13, efficiency 99.97% down to 0.3µ
  • Prefilters : eu6, efficiency 95% down to 5µ

Standard Model Specification

Model ACC-GC-8H ACC-GC-8V
HEPA Area 915 x 460mm 915 x 460mm
Working Dimension 930 (W) x 600 (D) x 1220(H)mm 915 (W) x 600 (D) x 1065(H)mm
Outer Dimension 1050 (W) x 700 (D) x 1800 (H)mm 1165 (W) x 600 (D) x 1600 (H)mm
Type Non FLP/ FLP Non FLP/ FLP

 

Clean Level 100 particles of size 0.5µ / F³
ISO Class 5 (ISO 14644-1:1999 (E))
Air Velocity 90 FPM (0.45MPS) ± 20 %
Noise Level <65 DB (A scale)

Note :

  • Garment Storage Cubical system is with a variety of standard dimensions. Also our booths can be custom engineered to any size.
  • Vibration <2.5m (0.0001”)
View Complete Details

Hvac System

You’ve probably heard of the term from different contractors, engineers, or perhaps colleagues and business partners; but you’re still wondering what the initialism means. Well, HVAC (“H-V-A-C” or “H-VAK”) stands for Heating, Ventilation, and Air-Conditioning—three closely related fundamental functions found in homes, offices, and other building structures. The beginning of HVAC is not clear, though as early as second century, a lot of Roman cities were using a central heating system known as hypocaust. This is further popularized during the Industrial Revolution as big factories used it. Now most modern buildings that you see have integrated HVAC. The HVAC system is also known as climate control. This is because these three functions are essential in maintaining comfort in every dwelling. The primary use of HVAC is to regulate room temperature, humidity, and air flow, ensuring that such elements remain within their acceptable ranges. Effective control of such factors minimizes health-related risks. A very humid atmosphere impairs the body’s ability to regulate body temperature as it prevents the evaporation of sweat. High humidity also decreases physical strength, which usually leads to fatigue. An unhealthy surrounding can also affect people’s thinking abilities. Hypothermia, heat stroke, and hyperpyrexia, among others, are some of the illnesses that may also occur.

 

Application of HVAC

  • Clean Rooms
  • Pharmaceutical Organization,
  • Hospital environments
  • Nano technology
  • Biotechnology
  • Micro electronics
  • Aerospace
  • Office spaces
  • Other Building facilities
View Complete Details

Modular Clean Room

Pharma Air Modular Systems Clean Room Partitioning System is designed for ease of installation and practical functionality, while maintaining modular flexibility to interchange by way of easy of demountability.
Whether you are adding on, modifying an existing facility, or constructing a new facility, the Pharma air modular systems panel system offers materials to suit your specific application.
The PAMS system can be integrated with a wide range of new or existing systems to coordinate any clean room facility or manufacturing environment. Simplified construction methods and our progressive/ non-progressive system will help minimise overall construction time.
Solid Panels for Clean Room PartitionsPharma Air Modular Systems monoblock/modular solid partitioning walls are fabricated by way of nominal 2x1/0.8/1mm hot dipped galvanized steel sheets conforming to JISG 3302/94, LFQ, light chromated, zero spangle with a zinc coating of 120gsm. They are bonded with an infill of honeycomb paper core or high density mineral wool, forming a rigid 80mm thick panel to modular widths of 160mm to 1200mm and 2445mm to 6000mm in height.
Pharma Air Modular Systems modular walls have been installed in clean rooms throughout the world in a range of applications from high technology electronic manufacturing to legislation-controlled healthcare packaging.
The system is readily adaptable to meet the requirements of most clean room classifications as determined by PAMS grades used in pharmaceutical applications. Make-up panels are produced within the sizing layout of the drawing. Pre-treatment of panels is done by way of Corro-Zinc 97 and epoxy polyester powder coating of 60/80 microns forming a smooth surface finish.
A complete range of partition walls and ceiling systems are available to meet the technical specifications of controlled environment rooms. Ceilings as well as partitions are inert, non particle-shedding, forming part of a clean room aseptic envelope to enable compliance with FDA validation procedures and PAMS standards.
Full details of the complementary range of ceiling systems are available on request.

 

Metal DoorsetsMetal doorsets are manufactured from prime quality stretched cold formed steel sheet to ASTM A527 ASTM A525, JISG 3302/1994, BS 2989. Door frames are pressed from 1.5 mm thick galvanized steel sheet with mitred and welded construction.
Hinge reinforcements for either 1 pair or 11/2 pair of hinges are manufactured from 4mm thick steel plate and welded to the frame.
The door leaf is manufactured from 0.8/1mm thick galvanized steel sheet with lock formed edges. It is insulated and bonded with infill of honeycombed paper core/mineral wool, forming a rigid flush-fitting stress-free level leaf that will withstand high levels of duty without failure.
Innovative flush double glazed 400x800mm vision panels are available, constructed with vacuum-sealed 6mm clear toughened glazing units. Finished in polyester powder coating of 60/80 microns forming a smooth surface finish.

 

Metal Type

  • Electro Galvanized Steel, EG (Pure Zn, ASTM A591)
  • Galvannealed Steel (with A60 Zinc Coating conformation to ASTM A25)
  • Cold Rolled Steel (ASTM 366-91)
  • Stainless Steel (Type 304 stainless steel, # 4 finish PVC coated)

The System

System 1200mm, 1000mm and 900mm as standard. Panel thickness 60/80/100mm. Ability to carry and conceal services and return air ducts/ risers.
Height Up to 6000mm with provision for stacked panels for higher application.
Base Detail Recessed adjustable base section to allow a flush coved finish.
Insulation Bonded mineral wool or polyisocyanurate foam cores assure absolute panel rigidity. Alternative cores available, such as honeycomb papercore/ aluminium.
Weight 9kg/m2 to 25kg/m2 dependant upon specification and thickness.
Surface Finish Electrostatically applied epoxy polyester powder coated finish applied in suitable RAL colours.
Panel Connection Each panel is connected to its adjacent unit or door unit with a friction-type interlocking key. This allows speedy erection and dismantling.
Glazing Double flush glazing with 6mm toughened glass on both sides within a stainless steel framing.
Doors Steel construction; optional double and single glazed apertures.
Acoustics Solid panel; Rw 41 dB - (BS 5821)
Coving Optionalradiused accessories. floor/ceiling coving
Air Leakage Silicone for sealed applications.

 

Standard Steel Sheet Thickness

Door 0.6mm (24 gauge), 0.8mm (22 gauge), 1.0mm (20 gauge) {Rolled Seams}
1.2mm (18 gauge), 1.6mm (16 gauge) {Welded Seams}
Frame 1.6mm (16 gauge) {Mitre/ welded corners and knock-down bolted frames}

 


Pharma Air Modular Systems Metal Doorsets And Frames (Model Specification)

Description Pharma Air Modular Systems Metal Doorsets and Frames
Construction

Door leaf from 1.0mm (1.2mm) (1.6mm) thick slip coated pre-galvanised steel sheet to ASTM A527/ ASTM A525, JIS G 3302 or BS 2989 (1994). Zinc coating 80-120 g/m2. Lock formed panels with internal stiffeners, 3.0mm thick hinge reinforcing, hardware mounting plates and lock protection.

Door frame from 1.2mm (1.6mm) (2.0mm) thick pre-galvanised steel sheet with mitred and welded corners, frame stretchers, hinge reinforcing plates, fixing plates and hardware mounting plates.

Core Materials Door leaf filled with either rockwool, honeycomb, infill dependant on duty.
Finish Powder coated surface.
Fixings Fixing through frame by expansion bolt.
Mortar straps.
Frame Assembly Welded construction with frame spreaders.
Bolted frame construction.
Knock-down frame construction for wrap around frames.
Panel Connection Glazing to door leaf.
Glazed overpanels in frames.
Glazing Louver panels to door leaves.
Fire resistant ventilators.
Louvers Up to 2 hours fire resistance in accordance with BS 476 Part 22 dependant on construction.
Fire Resistant Up to RW 44 for 60mm thick doorleaves with special frames and ancillary seals.
Acoustic Properties Up to 3000 mm high and 3000 mm wide subject to test data limitations.
Sizes Silicone for sealed applications.

 






Graph 01


Download Detail File : Click Here

Graph 02


Download Detail File : Click Here

Graph 03


Download Detail File : Click Here

Graph 04


Download Detail File : Click Here

Graph 05


Download Detail File : Click Here

Graph 06


Download Detail File : Click Here
View Complete Details

Sterilizing Tunnel

Our company specializes in offering qualitative range of Sterilizing Tunnel. This range of sterilization tunnels is designed using modern machinery, which makes these ideal for sterilization and drying of ampules and varied bottles like vials and oral liquid bottles in pharmaceutical industry. Along with this, the offered range is categorized in 3 wings (preheating zone, heating zone and cooling zone) in accordance with the diverse demands of clients.

View Complete Details

Fume Hood

A Fume Hood or fume cupboard is a type of ventilation device that is designed to limit the user's exposure to hazardous or noxious fumes, vapors or dusts. A fume hood is typically a large piece of equipment enclosing five sides of a work area, the bottom of which is most commonly located at a standing work height.

 

Fume hoods serve to control exposure to toxic, offensive or flammable vapors, gases and aerosols. Fume hoods are the primary method of exposure control in the laboratory.

 

Fume Hood cabinet inside Negative pressure, there for control exposure to toxic, offensive or flammable vapors, gases and aerosols.

 

Two main types exist, ducted and reticulating. The principle is the same for both types: air is drawn in from the front (open) side of the cabinet, and either expelled outside the building or made safe through filtration and fed back into the room.

 

Fume Hood is available in, SS 304 / SS 316 / SS 316L, CRCA Powder coated.

 

Unit Description

  • Construction are Stainless Steel Body OR CRCA Powder coated
  • Differential Pressure Gauge
  • Milky White Light
  • Feather Touch
  • Motor Blower Assemblies : 0.5 HP, 230 V, 1 phase, 50 Hz
  • HAPA Filters (Final Filter) : H13, Efficiency 99.97% down to 0.3µ
  • Exhaust HAPA Filters : H13, Efficiency 99.97% down to 0.3µ
  • Prefilters : EU6, Efficiency 95% down to 5µ
  • Ultra violate Light
  • Hour Meter
  • Sliding Glass Door

 

Optional Accessories

  • Stainless steel perforated grille for HEPA Filter
  • Filter blocked alarms

Standard Model Specification

Fume Hood is with a variety of standard dimensions. Also our booths can be custom engineered to any size.

Model ACC-FH
HEPA Area 1830 x 1220mm
Working Dimension 2075 (W) x 1420 (D)mm
Outer Dimension 2075 (W) x 1420 (D) x 1500 (H)mm
Type Non FLP/ FLP

 

Technical Specification

Clean Level 100 particles of size 0.5µ / F³
ISO Class 5(ISO 14644-1:1999 (E))
Light intensity > 300 lux
Air Velocity 90 FPM (0.45MPS) ± 20 %
Noise Level <65 DB (A scale)
Vibration <2.5m (0.0001”)
Power Supply ~230 V, 1 phase, 50 / 60 Hz

 

View Complete Details

HEPA Filters

We are offering to our customers HEPA Filters with high dust retention and flow rate. We offer the interchangeable HEPA Filters in different sizes to cater to varying the customer’s demand. The filter media is fire retardant assembled in a rigid aluminum frame. The filer medium also comprises a locking insert and is bonded in the frame using fire retardant adhesive. The fire retardant gasket of the HEPA Filters offer protection against leakages. We manufacture our HEPA Filters as per the standard industrial parameters. The particles are removed down to 0.3 micron from high particle airgas flow passing through the HEPA Filters with efficiency more than 99.97%. Having a large filtration area, the HEPA Filters are constructed from non-woven fiberglass media paper.

Types of HEPA Filter :

  • Minipleat HEPA Filter
  • High temperature HEPA Filter
  • Aluminum HEPA Filter (100% DOP)
  • Aluminum HEPA Filter (50% DOP)


Properties :

  • Resists to mildew
  • Resistant to fungal
  • Resistant to bacteria
  • Resistant to corrosive chemical fumes
  • Resistant to hydrofluoric acid


Features :

  • Easy handling
  • Easy cleaning
  • Easy removable
  • Easy install
  • Use to temp. Range (100o-600oc)
View Complete Details

Pre Filters

We are a reputed Manufacturer and Supplier of Pre Filters known for efficiency and high performance. Our Pre Filters remove all the particles down to 5 micron from high particle airgas passing through them. Our Pre Filters are very efficient offering an efficiency of more than 765 percent. Our Pre Filters are designed to ensure a large filtration area in ratio to the face area. The filter element of the Pre Filters is constructed from “glass fiber” papers, which is sandwiched between 2 layers for 5 micron and 1 layer for 10 micron. The filter media is fire retardant while the filter house is bonded on side using long life adhesive. The filter house is made from high-grade stainless steel sheet frame with flange.

Types of Pre Filters :

  • 3 Micron Pre Filter
  • 5 Micron Pre Filter
  • 10 Micron Pre Filter


Properties :

  • Resistant to mildew
  • Resistant to fungal
  • Resistant to bacteria
  • Resistant to corrosive chemical fumes
  • Resistant to hydrofluoric acid


Features :

  • Easy handling
  • Easy removable
  • Easy cleaning
  • Easy install
  • Use to temp. Range (100o-600oc).
View Complete Details

Stainless Steel Cleaning Cart

To move your sterile products in a safe manner, we are offering Stainless Steel Cleaning Cart. Backed by our highly competent team of professionals and sound infrastructure, we assure about the high performance of our Stainless Steel Cleaning Cart. Our Stainless Steel Cleaning Cart is mobile and light in weight due to which it can be used for transporting sterile products under ISO class 5 particle free work area. We offer the Stainless Steel Cleaning Cart in different varieties including SS 304 SS 316 SS 316L, CRCA powder coated.

Unit Description :

  • Construction : stainless steel body or CRCA powder coated
  • Differential pressure gauge
  • Glass stainless steel door
  • Milky light
  • Feather touch
  • Ultra violate light
  • Hour meter
  • 35 to 40 minute battery backup
  • Castor wheel
  • Motor blower assemblies : 0.5 hp, 230 v, 1 phase, 50 hz
  • HEPA filters (final filter) : h13, efficiency 99.97% down to 0.3µ
  • Pre filters : eu6, efficiency 95% down to 5µ

Technical Specifications

Model ACC-CC-4
HEPA Area 915 x 760mm
Working Dimension 410 (W) x 960 (D) x 800(H)mm
Outer Dimension 960 (W) x 960 (D) x 1525 (H)mm
Type Non FLP/ FLP

Clean Level

100 particles of size 0.5µ / F³

ISO Class

5 (ISO 14644-1:1999 (E))

Air Velocity

90 FPM (0.45MPS) ± 20 %

Noise Level

<65 DB (A scale)

Vibration

<2.5m (0.0001”)

Power Supply

~230 V, 1 phase, 50 / 60 Hz

Note : Mobile Clean Carte system is with a variety of standard dimensions. Also our booths can be custom engineered to any size.

View Complete Details

Biological Safety Cabinet

 When properly maintained and used in conjunction with good laboratory techniques, BSCs provide effective primary containment for work with human pathogens. In containment level 2 facilities, BSCs are used for procedures with the potential to produce infectious aerosols and for high concentrations or large volumes of infectious material. In containment levels 3 and 4, all open vessel activities with infectious materials are conducted in a BSC. Every employee working in a BSC must be trained in its correct use and have a good understanding of the different types of cabinets and how they work.

Classes and Characteristics of Biological Safety CabinetsThere are three classes of BSC: Class I, Class II and Class III. Selection of the proper class of BSC requires careful evaluation of the activities to be carried out. Horizontal, clean benches that direct air towards the operator are not biological safety cabinets and must not be used for handling infectious, toxic or sensitizing materials.

Class I Cabinets (Figures 1a and 1b)These cabinets have unrecirculated airflow away from the operator that is discharged to the atmosphere after filtration through a HEPA filter. They provide good operator protection but do not protect the material within the cabinet (the product) from contamination.

Class II Cabinets (Figures 2-5)Class II cabinets are designed for personnel, product and environmental protection. They are designed for work involving microorganisms in containment levels 2, 3 and 4 laboratories and are divided into two types (A and B) on the basis of construction type, airflow velocities and patterns, and exhaust systems.Within type (A), there are two subtypes, A1 (formerly designated type A) and A2 (formerly designated type B3). Within type (B), there are two subtypes, B1 and B2. Class II cabinets are most commonly used in biomedical research laboratories because of their characteristics.

Class II, Type A1 Cabinets (Figure 2)Cabinet air may be recirculated back into the laboratory or ducted out of the building by means of a "thimble" connection (i.e., a small opening around the cabinet exhaust filter housing) whereby the balance of the cabinet is not disturbed by fluctuations in the building exhaust system. The thimble must be designed to allow for proper certification of the cabinet (i.e., provide access to permit scan testing of the HEPA filter).Maintain a minimum average face velocity of 0.38 m/s (75 ft/min).May have positive pressure contaminated ducts and plenums. Are not suitable for work with low levels of volatile toxic chemicals and volatile radionuclides.

Class II, Type A2 Cabinets (Figure 3)

  • Cabinet air may be recirculated back into the laboratory or ducted out of the building by means of a "thimble" connection (i.e., a small opening around the cabinet exhaust filter housing) whereby the balance of the cabinet is not disturbed by fluctuations in the building exhaust system. The thimble must be designed to allow for proper certification of the cabinet (i.e., provide access to permit scan testing of the HEPA filter).
  • Maintain a minimum average face velocity of 0.5 m/s (100 ft/min).
  • Have ducts and plenums under negative pressure.
  • Is suitable for work with minute quantities of volatile toxic chemicals and trace amounts of radionuclides.

 

Class II, Type B1 Cabinets (Figure 4)

  • Hard-ducted through a dedicated duct exhausted to the atmosphere after passage through a HEPA filter; contain negative pressure plena.
  • Maintain a minimum average face velocity of 0.5 m/s (100 ft/min).
  • Recirculate 30% of the air within the cabinet.
  • Suitable for work with low levels of volatile toxic chemicals and trace amounts of radionuclides.


Class II, Type B2 Cabinets (Figure 5)

  • Does not recirculate air within the cabinet.
  • Maintain a minimum average face velocity of 0.5 m/s (100 ft/min).
  • Hard-ducted through a dedicated duct exhausted to the atmosphere, 100% of cabinet air, after passage through a HEPA filter; contain negative pressure plena.
  • Suitable for work with volatile toxic chemicals and radionuclides.

The exhaust canopy must allow for proper BSC certification. An alarm should be provided that is audible at the cabinet to indicate loss of exhaust flow from the building exhaust system. The cabinet internal fan should also be interlocked to shut down when the building exhaust system fan fails, to prevent pressurization of the cabinet.

Class III Cabinets (Figure 6)Class III cabinets are totally enclosed and gas-tight with HEPA filtered supply and exhaust air. Work is performed with attached long-sleeved gloves. The cabinet is kept under negative pressure of at least 120 Pa (0.5 in. w.g.), and airflow is maintained by a dedicated exterior exhaust system. Class III cabinets protect the worker and the product. They are designed for work with level 4 pathogens and provide an alternative to the positive-pressure suit made for maximum containment laboratories. Cabinet lines consisting of several Class III cabinets (e.g., for centrifuges, animal cages, incubators, refrigerators) and transfer devices joined together are traditionally custom built. Specific guidance on the unique requirements for constructing, installing, certifying and using Class III cabinet lines can be found elsewhere. The exhaust air is double HEPA filtered or treated by HEPA filter and incineration. Removal of materials from the cabinet must be through a dunk tank, double door autoclave or air-lock pass-through for decontamination. Interlock or protocols must be used for the autoclave and pass-through doors to prevent both doors from being open at the same time.

 

Use of the Cabinet
Follow these start-up procedures when preparing for work in the BSC :

  • Turn off UV lights if in use and ensure that the sash is in the appropriate position.
  • Turn on fluorescent light and cabinet blower, if off.
  • Check the air intake and exhaust grilles for obstructions.
  • If the cabinet is equipped with an alarm, test the alarm and switch it to the "on" position.
  • Confirm inward airflow by holding a tissue at the middle of the edge of the viewing panel and ensuring that it is drawn in.
  • Disinfect the interior surfaces with a suitable, noncorrosive disinfectant.
  • Assemble all materials required for the procedure and load them into the cabinet; do not obstruct the air grilles; the working surface may be lined with absorbent paper with plastic backing; segregate "clean" items from "contaminated" items.
  • Wait 5 minutes to purge airborne contaminants from the work area.


Follow these procedures for working in the cabinet :

  • Don protective clothing and gloves as appropriate.
  • Perform operations as far to the rear of the work area as possible.
  • Avoid movement of materials or excessive movement of hands and arms through the front access opening during use; when you do enter or exit the cabinet, do so from straight on; allow the cabinet to stabilize before resuming work.
  • Keep discarded, contaminated material to the rear of the cabinet; do not discard materials in containers outside of the cabinet.
  • Do not work with open flames inside the cabinet.
  • If there is a spill during use, surface decontaminate all objects in the cabinet; disinfect the working area of the cabinet while it is still in operation (do not turn the cabinet off).


Follow these procedures upon completion of the work :

  • Allow the cabinet to run for 5 minutes with no activity.
  • Close or cover open containers before removing them from the cabinet.
  • Surface disinfect objects in contact with contaminated material before removal from the cabinet.
  • Remove contaminated gloves and dispose of them as appropriate; wash hands.
  • Don clean gloves, and ensure that all materials are placed into biohazard bags within the cabinet.
  • Using a suitable non-corrosive disinfectant (e.g., 70% ethanol), disinfect interior surfaces of cabinet; periodically remove the work surface and disinfect the area beneath it (including the catch pan) and wipe the surface of the UV light with disinfectant.
  • Turn off the fluorescent light and cabinet blower when appropriate (some cabinets must be left on at all times; if you are unsure, check with your cabinet certifier, safety officer or building maintenance personnel).
  • Turn on the UV light if appropriate (do not turn on when people are working close by); UV must be tested to ensure that it is emitting a germicidal wavelength (ask your cabinet certifier to perform this test).


Unit Description

  • Construction are Stainless Steel Body OR CRCA Powder coated
  • Differential Pressure Gauge
  • Milky White Light
  • Feather Touch
  • Motor Blower Assemblies : 0.5 HP, 230 V, 1 phase, 50 Hz
  • HAPA Filters (Final Filter) : H13, Efficiency 99.97% down to 0.3µ
  • Prefilters : EU6, Efficiency 95% down to 5µ


OPTIONAL ACCESSORISE

  • Stainless steel perforated grille for HEPA Filter
  • Glove ports
  • Filter blocked alarms
  • Stands
  • Hour meter
  • Ultraviolet light

Biological Safety Cabinet is with a variety of standard dimensions. Also our booth.

Figure 1a


Download Detail File : Click Here

Figure 1b.


Download Detail File : Click Here

Figure 2


Download Detail File : Click Here

Figure 3


Download Detail File : Click Here

Figure 4


Download Detail File : Click Here

Figure 5


Download Detail File : Click Here

Figure 6


Download Detail File : Click Here

Technical Specification

Clean Level 100 particles of size 0.5µ / F³
ISO Class 5(ISO 14644-1:1999 (E))
Light intensity > 300 lux
Air Velocity 90 FPM (0.45MPS) ± 20 %
Noise Level <65 DB (A scale)
Vibration <2.5m (0.0001”)
Power Supply ~230 V, 1 phase, 50 / 60 Hz
View Complete Details
Tell Us What are you looking for? Will call you back

Contact Us

  • B N Patil (Pharma Air Modular Systems)
  • 213, Vikas Height, 2nd Floor, Opp. HDFC Bank, Santoshi Mata Mandir Road, Kalyan (West), Kalyan West, Thane, Maharashtra - 421301, India
  • Share us via
  • Call 08068051345 Ext. 766